Log:
Évaluations - 3, GPA: 4 ( )

Instructions York, Modèle AHP18

Fabricant : York
Taille : 189.34 kb
Nom Fichier : dfc3b154-c9bb-49e7-9032-c7cc4b6e937a.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


The AHP (non-variable speed motor) models can be ordered upflow only or as multi-position. The multi-position model can be installed in downflow, upflow, horizontal right or left without the need for additional field installed kits. All UPG air handlers and coils utilize a TXV to provide our customers with the optimum performance and refrigerant control required for 13+ SEER systems. Air handlers can be ordered with R410A TXV factory installed. Air handlers are also available with “Flex-coils” without a factory installed metering device. For added flexibility, an R22 or R410A TXV can be field installed to meet your refrigerant choice. FEATURES Thermal Expansion Valve - Provides the ultimate refrigerant control required for today's high efficient product. The UPG bolton TXV provides the added flexibility to convert the air handler to the required refrigerant. The UPG TXV is a true bolt-on which does not require brazing to replace or install. Insulated Cabinet - All air handler cabinets are thermally insulated with 1” foil faced insulation (R-4.2) to prevent sweating. For applications in extreme humidity conditions an optional, field installed, external insulating wrap kit is also available. Factory - Sealed to achieve 2% or less leakage rate with or without field installed filter at 1.0” water gauge external static pressure. Durable Finish Inside and Out - Air handler casings are made of pre-painted galvanized steel which provides a better paint to steel bond that resists corrosion and rust creep. All internal coil sheet metal parts are made of G90 galvanized. High Efficiency - 5 ton unit has high efficiency DC motor. 4 HK Heat Kit - Installation friendly, easy service, more robust, unique to new design. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 255029-YT G-M-0610 DIMENSIONS BOTTOM INLET DIMENSIONS FOR HORIZONTAL APPLICATIONS Dimensions Dimensions Wiring Knockouts1 Refrigerant Connections Line Size MODELS A B C D E F J K Height Width Depth Power Control Liquid Vapor AHP18B3XH21 AHP18B4FH21 46 17.5 12-3/8 13-29/32 14-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 3/4” AHP24B3XH21 AHP24B4FH21 46 17.5 12-3/8 13-29/32 14-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 3/4” AHP30B3XH21 AHP30B4GH21 AHP30B4HH21 AHP30B4FH21 46 17.5 12-3/8 13-29/32 14-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 3/4” AHP36C3XH21 AHP36C4GH21 AHP36C4HH21 AHP36C4FH21 52 21 21.5 17-1/8 17-13/32 18-3/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 7/8” AHP42C3XH21 AHP42C4HH21 52 21 17-1/8 17-13/32 18-3/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 7/8” AHP48D3XH21 AHP48D4HH21 AHP48D4JH21 57 24.5 22-1/8 20-29/32 21-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 7/8” AHP60D3XH21 AHP60D4JH21 57 24.5 22-1/8 20-29/32 21-19/32 7/8” (1/2”) 1 3/8” (1”) 1 23/32” (1 1/4”) 7/8” (1/2”) 3/8” 7/8’ 1. Actual size (Conduit size). H indicates 4 position model. 2 Johnson Controls Unitary Products 255029-YTG-M-0610 COIL TECHNICAL DATA Models Application Refrig. Conn. Types Face Area (Sq. Ft.) Rows Deep Fin Per In. Coil Size Tube Geometry Tube Dia. Fin Type TXV AHP18B3XH21 Cooling / Heat Pump Sweat 3.40 2 14 (2) 14 x 17.5 1 x 0.866 3/8 Enhanced None AHP18B4FH21 4E AHP24B3XH21 Cooling / Heat Pump Sweat 3.89 2 14 (2) 16 x 17.5 1 x 0.866 3/8 Enhanced None AHP24B4FH21 4F AHP30B3XH21 Cooling / Heat Pump Sweat 3.89 3 12 (2) 16 x 17.5 1 x 0.866 3/8 Enhanced None AHP30B4GH21 4G AHP30B4HH21 4H AHP30B4FH21 4M AHP36C3XH21 Cooling / Heat Pump Sweat 4.86 3 12 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced None AHP36C4GH21 4G AHP36C4HH21 4H AHP36C4FH21 4M AHP42C3XH21 Cooling / Heat Pump Sweat 4.86 3 12 (2) 20 x 17.5 1 x 0.866 3/8 Enhanced None AHP42C4HH21 4H AHP48D3XH21 Cooling / Heat Pump Sweat 5.83 3 11 (2) 24 x 17.5 1 x 0.866 3/8 Enhanced None AHP48D4HH21 4H AHP48D4JH21 4J AHP60D3XH21 Cooling / Heat Pump Sweat 5.83 3 11 (2) 24 x 17.5 1 x 0.866 3/8 Enhanced None AHP60D4JH21 4J Note: H models are available with a factory installed horizontal drain pan. COOLING CAPACITY Models Rated CFM Entering Air °F (Dry / Wet Bulb) MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG 3б I 61.6 40 I 6S.6 4б I 76.0 б0 I S4.0 FULL-CASED “A” TYPE MULTI-POSITION AHP18B**H21 650 85/72 24.5 22.3 19.9 17.3 80/67 22.6 20.3 18.0 15.6 75/62 18.5 16.4 14.2 12.0 70/57 15.0 13.1 10.9 8.5 AHP24B**H21 800 85/72 35.0 31.8 28.4 24.7 80/67 32.2 29.1 25.7 22.3 75/62 26.4 23.4 21.0 17.1 70/57 21.4 18.6 20.2 12.1 AHP30B**H21 1050 85/72 41.5 37.8 33.7 29.5 80/67 36.2 32.4 28.6 24.5 75/62 29.1 25.3 24.0 19.2 70/57 24.1 21.5 18.7 15.8 AHP36C**H21 1200 85/72 51.3 46.7 41.7 36.8 80/67 41.1 36.3 31.8 27.1 75/62 32.1 27.0 29.4 21.9 70/57 27.6 25.4 23.5 18....


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories