Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15 RAK204D15P 20 RAK204D20P 30 RAK204D30P* 14 Installation Instructions 265 VOLT ELECTRICAL SUPPLY JUNCTION BOX Remove the junction box cover by taking out the Remove the junction box by taking out the top rear . Note how the tab on the lower right corner ves to hold the side in place. This will help when the box is being reinstalled. The cord will be coiled up inside the junction box. 1 Unit connector Junction box cover Junction box Tab on unit Slot in junction box WARNING: Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electric Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code. These models must be installed using the appropriate GE power supply kit for the branch circuit amperage and the electrical resistance heater wattage desired. See the POWER CONNECTION CHART in these Installation Instructions. One of the following installation methods must be used: A Electrical subbase kits are available to provide a flexible enclosure for direct connection. The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. B For direct connection to branch circuit wiring inside the provided junction box without using a subbase kit, cut the cord, strip the wire ends and connect as follows. Branch Circuit and Proper GE Power Unit Amperage Rating Subbase Kit Supply Kit 15 RAK204E15 RAK5172 20 RAK204E20 RAK5202 30 RAK204E30 RAK5302 2 ATTACH CONDUIT 1 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box. Leave 6. of wire free at the end of the conduit to allow connections to be made. 3 Conduit NOTE: Order Kit RAK4002CW to enable a quick disconnect inside the junction box. CUT AND STRIP THE CORDSET 1 Remove the cordset from the power supply kit. Measure 6. down the cord from where it emerges from the back of the nylon plastic connector and cut the cord through at this point. 2 Carefully remove 3. of the cordset insulation so as to expose the three insulated wires. 3 Strip 3/4. of the insulation away at the end of each of the three wires (L1, Neutral and Ground). Plug the connector fully into place in the unit mating connector. Be sure the locking tabs at the sides are engaged. Connector 3/4. 3. 6. 2 If a fuse and fuseholder are to be used, the knockout at the top of the box is for mounting a Buss Fuseholder. Be sure the fuse and fuseholder are of the same rating as the branch circuit. Leadwires at the fuse can be either soldered in place or attached using UL-listed 1/4. female (receptacle) crimp connectors. 15 Installation Instructions 265 VOLT ELECTRICAL SUPPLY 4 REINSTALL JUNCTION BOX • Reinstall the junction box by engaging the tab at the lower rear, aligning the screw hole at the top and driving the one screw until secure. Be sure that all wire leads are inside the box and not pinched between the box and the unit. The green insulated ground wire from the unit MUST be connected to the branch circuit ground wire. Make all wire connections by using appropriate UL-listed electrical connectors and techniques (black to black, white to white and green to green). 5 REINSTALL JUNCTION BOX COVER 1 Carefully tuck all wires and connections back inside the junction box. Be sure there are no loose connections or stray uninsulated wires exposed. 2 Place the junction box cover in place. Replace the two screws removed earlier and tighten securely. 3 Discard the unused portion of the plug and the cordset. POWER CONNECTION CHART 230/208 Volt Power Wall Plug Heater Wattage Supply Kits Configuration Circuit Protective Device @ 230/208 Volts RAK3153 Tandem 15 Amp Time Delay Fuse or Breaker 2.55/2.09 KW RAK3203 Perpendicular 20 Amp Time Delay Fuse or Breaker 3.45/2.82 KW RAK3303* Large Tandem 30 Amp Time Delay Fuse or Breaker 5.00/4.10 KW 265 Volt Power Wall Plug Heater Wattage Supply Kits Configuration Circuit Protective Device @ 265 Volts RAK5172 Does Not Apply 15 Amp Time Delay Fuse or Breaker 2.55 KW RAK5202 Does Not Apply 20 Amp Time Delay Fuse or Breaker 3.45 KW RAK5302* Does Not Apply 30 Amp Time Delay Fuse or Breaker 5.0 KW * Not recommended for use on 7000 BTUH units. 16 Installation Instructions 17 INSTALL THE WALL CASE AND EXTERIOR GRILLE 1 The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case. 2 Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out. 3 Install the exterior grille from the room side following instructions packed with the grill. Insulated Wall Case This unit is designed to be installed in a GE plastic or an insulated steel ...