Log:
Évaluations - , GPA: ( )

Instructions La Pavoni, Modèle LP30

Fabricant : La Pavoni
Taille : 2.58 mb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


All of these visualizations, and other eventual warning signs that can appear in particular situations, appear in sequence and with a time programmable from the "Time visualiz. Status” parameter. A characteristic of the board is that to alternate the previous sequence of the status scheme with a certain number of “Spots” . These are full screen graphic images which can be designed using any graphic program on a PC. You will need to create a file for each Spot of the BITMAP type, monochrome with resolution 128x64 and download to the board using the relevant software on a PC with a normal serial cable RS232. At this point it is enough to program the number of seconds of visualization requested for each Spot. Up to 8 Spots can be downloaded to the board and kept at disposition for activation on particular occasions. Available in this menu are other parameters such as an identity number for the machine and a communication address for the programming portal (for the management of more than one machine with the same PC or other method of external supervision). The “Machine model” parameter must be programmed depending on the particular machine so that the board can manage in the appropriate way all specific functions. The “Operator Code” permits a number to be programmed to be used as a password for access to the machine menu. A code equal to 0 deactivates the request for the password whilst it is possible to insert a number using all 10 numbers from 0 to 9. When the password is requested the keypad can be used to digit the value directly. The keys from 1 to 5 have a second function when the "Shift” (7) key is pressed: 1X6 2X7 4X9 5X0 7 Shift» 8 OK II 9 Esc I Note: entering the principal service menu with the appropriate key when a password has been programmed, the introduction of the code is requested. Here there are two possibilities. Pressing directly "OK” (8) enters the principal menu without password and in this case certain menus will not be accessible without later inserting the password. Instead, inserting the correct password using keys “1”-“5” and "Shift” all menus will be accessible up to exiting the service menu. “Clock set-up” Menu > Set time/date > On/off programs “Set time/date” allows the regulation of the date and current time on the machine clock. This clock is used for various machine functions. Apart from visualizing in the pause between vends, the clock is used to update the expiry of the products (when used), to manage the turning on and off of the different parts of the machine according to certain programs and to provide the data-logger records of the time/date information on particular events. “On/off Programs” contains a list of 16 programs to turn on and off the refrigerator group, the display case illumination and the display. If the illumination has been turned off by a program, it is possible to momentarily turn it back on again pressing any key on the keypad and thus allowing a vend. Each on/off program consists of a total of 8 fields of which the first 7 identify a particular condition of time/date whilst the last is of the on/off status desired departing from that time/date. The programs are constantly verified departing from program 1 up to program 16. All programs in which the time/date is verified (the current time/date is the same or more than that of the program excepting the field “Day of the week” which requires the program only of equality) define as valid their on/off status. Consequentially, if more programs see their condition of time/date verified, the valid on/off status will be that of the last verified program and so the priority is more as much as the number of programs is more. In defining the time/date condition of a program the use of the value “whichever” is very important to specify that that field is not important for that condition. Programming the field “Year” to 2099 makes the relevant program un-influential in that, independent of other fields, the condition will not be verified until 2099. Some examples of programs: Example 1. Needs a weekly program the same for all the weeks of all the years: Monday-Friday from 8:30 to 18:30 all access Saturday-Sunday all off Prog. Day of the week Day of the month Month Year Hour Minute Sec. Status on/off 1 * * * * 8 30 * ON-ON-ON 2 * * * * 18 30 * OFF-OFF-OFF 3 Saturday * * * * * * OFF-OFF-OFF 4 Sunday * * * * * * OFF-OFF-OFF 5 * * * 2099 * * * * 6 * * * 2099 * * * * 7 * * * 2099 * * * * 8 * * * 2099 * * * * 9 * * * 2099 * * * * 10 * * * 2099 * * * * 11 * * * 2099 * * * * 12 * * * 2099 * * * * 13 * * * 2099 * * * * 14 * * * 2099 * * * * 15 * * * 2099 * * * * 16 * * * 2099 * * * * Note: the character * signifies “Whichever”. Example 2. Needs a weekly programming the same for every week of every year: Monday-Friday Saturday Sunday from 8:30 from 9:30 to 18:30 to 13:30 all access all access all off Prog. Day of the week Day of the month Month Year Hour Minute Sec. Status on/off...

Ce manuel est également adapté pour les modèles :
transformation des aliments - LP25 (2.58 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories