If pump runs but does not pump water: 1. Check for airlock. Be sure that outlet hose runs upward to the thru-hull connector, with no dips. (Figure 1) 2. Remove pump housing from base. Remove debris from chamber and impeller. Be sure impeller is firmly attached to shaft and is not cracked or broken. (Figure 2) If pump does not run: 1. Check fuse. Be sure electrical connections and fuse are waterproof and haven’t loosened. (Figure 3) To replace motor cartridge: 1. Hold pump housing, depress motor

Téléchargements : 0   Taille : 460 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

Twist counter-clockwise and remove pump housing from base. It is not necessary to remove motor cartridge for installation. (Figure 2) Figure 2 Press Tab To Unlock Motor Cartridge ReplacementMotor Cartridge Tab UnlockLock Lock Unlock Pump Housing (3) #8 Fasteners Base Strainer 1/8" Pilot Holes 2. Use base as template to mark 3 mounting holes in mounting pad. CAUTION: Do not drill through hull. Before drilling be sure mounted pump will be correctly positioned with pump nozzle pointing toward thru-

Téléchargements : 16   Taille : 460 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

To prevent personal injury, disconnect the power source when installing or servicing this product. Always remove the boat from the water before using 120V AC power tools. DO NOT use pump to remove gasoline, oil or other flammable liquids. Always use the fuse amperage rating specified for your pump model. Failure to do so could result in serious personal injury or fire hazards. Attwood bilge pumps are designed to exhaust STANDING WATER ONLY. They are not intended to prevent rapid accumulation of

Téléchargements : 0   Taille : 460 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

Position pump in the lowest accessible part of the bilge. On sailboats, location should be centered over keel. (Figure 1) Thru-Hull Connector Hose & Clamp Hose MUST Rise Upward with NO DIPSuitable Mounting Pad Base Strainer 12" min. Above Water Line 2. Do not mount pump directly to hull. Attach base strainer to a marine plywood mounting pad that is fiberglassed to the hull. HOSE CONNECTION INSTRUCTIONS IMPORTANT: To prevent airlock, hose must rise continually upward to the thru-hull connector wi

Téléchargements : 5   Taille : 460 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

4. Replace base. Attach with #8 stainless steel fasteners. 5. Re-attach pump to base. Insert into base, twist clockwise until tab snaps in and prevents turning. (Figure 2) WIRING INSTRUCTIONS Make all wire connections above the highest water level. Use marine grade wire connectors only. Waterproof all connections with suitable materials. (Figure 3) NOTE: Failure to make waterproof connections and fuse pump properly will void the product warranty. Figure 3 (neg) (pos) 2-Terminal On/Off Switch Bro

Téléchargements : 1   Taille : 459 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

Attwood products are warranted for use on pleasure boats. Any other use — including but not limited to commercial, racing, or non-marine use — are not covered under this warranty. Attwood’s obligation under this warranty is limited to repair of the product at Attwood’s plant or replacement of the products at Attwood’s option without expense to the original consumer purchaser. Any expenses involved in the removal, reinstallation or transportation of the product are not covered by this warranty. T

Téléchargements : 0   Taille : 459 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

REQUIRED FOR INSTALLATION • Adjustable wrench • Sabre saw • Length of 3/8" (9.5mm) I.D. hose • Screwdriver • Cordless drill and bits • Marine sealant WARNING: To prevent personal injury, always disconnect the power source when installing or servicing this product. Always remove the boat from the water before using any power tools. LOCATION Select an installation location that meets the following criteria: • Location on vessel must be able to withstand loads specified in application section. See

Téléchargements : 2   Taille : 459 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

G 04-04 APPLICATION Attwood flush pull-up cleats provide easy fittings NOTE: It is recommended that the installation of the Attwood boat builder, boat dealer, or a qualified marine mechanic. REQUIRED FOR INSTALLATION • Adjustable wrench • Sabre saw • Length of 3/8" (9.5mm) I.D. hose • Screwdriver • Cordless drill and bits • Marine sealant WARNING: To prevent personal injury, always disconnect the power source when installing or servicing this product. Always remove the boat from the water before

Téléchargements : 3   Taille : 459 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

Studded Version 1. After the cleat has been #8 self-tapping screws 2. Connect 3/8" inner diameter bilge or to a drain fitting. Figure 4 Water Receptacle (Sold Separately) Self-Tapping Screws• Hose Fitting • • • Marine Sealant• Studs• Backing Plate Nut • Lock Washer Studded Flush Cleat• Cut-Out Hole• • MAINTENANCE •A silicone based lubricant maybe used on cleat shafts to increase the ease of travel. If Attwood is unable to replace the product and repair is not commercially practical or cannot be

Téléchargements : 0   Taille : 459 kb   Fabricant : Attwood  
Catégorie : Bateaux
@name

REQUIRED FOR INSTALLATION • Adjustable wrench • Sabre saw • Length of 3/8" (9.5mm) I.D. hose • Screwdriver • Cordless drill and bits • Marine sealant WARNING: To prevent personal injury, always disconnect the power source when installing or servicing this product. Always remove the boat from the water before using any power tools. LOCATION Select an installation location that meets the following criteria: • Location on vessel must be able to withstand loads specified in application section. See