Log:
Évaluations - 2, GPA: 4 ( )

Instructions Desa, Modèle VANGUARD VDLCR30

Fabricant : Desa
Taille : 3.76 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


1. Remove logs, hearth kit, pan materials, and hardware from carton. 2. Remove all protective packaging applied to logs and base for shipment. 3. Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product. PRODUCT FEATURE ON/OFF SAFETY VALVE/PILOT Unit is tested and approved to ANSI Z21.60a-2000 and CSA 2.26a2000 as a vented decorative appliance. It is supplied with the parts and instructions to convert to propane/LP gas use. For more information, visit more information, visit 901268-01D 4 4 INSTALLATION Flue Opening Specifications Check Gas Type Venting Specifications for Installation INSTALLATION WARNING: The Massachusetts State Board requires all installations be performed by a Licensed Plumber or Gas Fitter. Massachusetts state code requires all vent dampers be welded open or removed. CAUTION: Do not remove the data plates attached to the burner pan. The data plates contain important warranty and safety information. WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. NOTICE: Installation, service, and repair of this appliance must be performed by a qualified installer, service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition. DESCRIPTION 18" Single Burner 50,000 40,000 .116 32 .081 46 24" Single Burner 60,000 50,000 .120 31 .082 45 18" Dual Burner 55,000 45,000 .116 32 .082 45 24" Dual Burner 65,000 55,000 .138 29 .086 44 30" Dual Burner 70,000 60,000 .1405 28 .089 43 Btu Input Natural Gas Btu Input Propane/LP Gas MINIMUM FIREBOX SIZES LOG FRONT BACK MINIMUM SIZE WIDTH WIDTH* DEPTH HEIGHT FLUE SIZE 18" 34" 16" 14" 18" 8" diam. 24" 35 3/4" 17" 15 1/2" 18" 8" diam. 30" 42" 27" 18" 18" 9" diam. *At depth indicated Figure 2 - Technical Information Charts Burner Orifice Natural Propane/LP In. Num. In. Num. SPECIFICATIONS (W.C.) FUEL INLET PRESSURE MANIFOLD PRESSURE Min. Max. NG 7 10.5 6 LP 11 14 10 FLUE OPENING SPECIFICATIONS Note:This vented appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted. The fireplace must include a working flue and venting system with the minimum openings shown in the Figure 2. CHECK GAS TYPE Use only natural gas. If your gas supply is not natural gas, you must convert the appliance to propane/LP. Follow the instructions on pages 6 and 7. If the fireplace does not have a gas supply shut-off valve, one must be installed. VENTING SPECIFICATIONS FOR INSTALLATION The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved. The chimney flue damper must be fixed open to provide a minimum of 81 sq. in. of free air opening during operation of this log set. A multipurpose damper clamp is provided to fix the damper in position. The minimum flue sizes shown in Figure 2 are based on a 6...

Ce manuel est également adapté pour les modèles :
équipement pour bateaux - VANGUARD FVDA18M (3.76 mb)
équipement pour bateaux - VANGUARD FVDA24M (3.76 mb)
équipement pour bateaux - VANGUARD FVDA30M (3.76 mb)
équipement pour bateaux - VANGUARD FVSA18M (3.76 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories