The hood will be installed in one of two ways. New VGG’s may be ordered with the hood already assembled (mounted to the top of the Rotisserie) or shipped with it for installation at the store location. VGG’s already in service may be fitted with the hood at a store location as a retro-fit installation. Disconnect VGG rotisserie from the electrical supply before attempting installation. VGH-8 Hood for use only with BKI Models VGG-8 or VGG-16 rotisseries. VGH-5 Hood for use only with BKI Model VGG-5 rotisserie. Detailed Installation Instructions 1. Remove side panel on the control side of the VGG and both side panels on the VGH. 2. Unscrew the 4 philips head screws of the access plate on the ceiling of the VGG and turn it around allowing hole to access the VGG control compartment. Reattach the plate with the 4 philips head screws. 3. Install the F0155 bushing provided into access hole of VGG. 4. Attach 1 of the FB68943018 (Appliance Lifting/Installation Bracket) handles on each side of the VGH using the bottom two holes that the side panels attach to and with screws removed from the side panels. The hood lifting/installation brackets (FB68943018) are used as lifting mechanism and are attached to the sides of the hood with side panels removed for placing the hood on top of the oven. Failure to install this part could cause damage to the hood and/or oven. 5. Pick up and place the VGH on the VGG making sure the controls are on the same side as the VGG controls. 6 Rotisserie Ventless Hood Installation Wiring Electrocution, equipment failure or property damage could result if an unlicensed electrician performs the electrical installation. Ensure that a licensed electrician perform the electrical installation. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is powered from a source other than the oven. The hood MUST receive its input power from the rotisserie for which it is mounted on. 1. Feed power wires and interlock wires through access hole into VGG. 2. The power wires # 14, 15, and ground are wired as follows: 3 phase, 3 wire 3 phase, 4 wire 3. For interlock, remove #5 wire from VGG Power Switch. Crimp male connector provided with VGH onto #5 wire and plug into female connector of VGH wire #11. Place VGH wire #10 into VGG Power Switch where #5 wire was. 4. Replace all side panels. 7 Rotisserie Ventless Hood Baffle Grease / Odor Filter These filters will come already installed in the hood. If not, follow the steps below to install the filters. 1. Remove the filter(s) from the plastic bag. 2. Open the hood and filters doors on the front of the unit by pulling on the handles. 3. Observing the “FRONT” marking on the grease filter and facing the control side of the hood away from the blower, slide the filter into the unit as shown. Repeat for the Charcoal filter with the “ARROW” mark showing air flow direction pointing towards the blower. 4. Close the filters and hood doors. 8 Rotisserie Ventless Hood Operation Operation Principles of Operation The hood requires a VGG rotisserie power supply, a two-wire connections tapped into the control circuits of the VGG it is mounted to, and the activation of a simple On / Off switch to operate. The wiring change to the VGG ensures that the rotisserie is inoperable until the filter and door switch circuits are satisfied (that is, the filters are present and the door(s) are closed). A blower inside the ventless hood draws cooking vapors through a grease baffle. Inside the baffle, the air reverses direction two times capturing particles of moisture, grease, and dirt. Material collecting on the baffle drains into the condensation trough located below the baffle. After air passes through the baffle, it then enters a charcoal odor filter. The charcoal odor filter helps to remove cooking odors from the air. The filtered air then passes through the blower and is returned to the room. The VGG oven may now be energized and operated normally. Refer to the Rotisserie manual on operations of the VGG. If a hood door is opened, the ”Door Latch” pilot light illuminates and a relay opens the control circuit in the VGG causing the VGG to immediately power off. If either filter is removed, the “Check Filters” pilot light illuminates and neither the hood or VGG will operate. Controls and Indicators 1 4 3 2 Item Label Description Function 1 Replace Filters Light Indicator This light illuminates to indicate time to change out the old filters to new ones. 2 Check Filters Light Indicator This light illuminates if either of the two filters or both are not in place. The hood will not run with this light on. 3 Door Latch Light Indicator This light illuminates if either of the hood front or rear glass door or both is open. The hood will not run if this light is on. 4 Power (0/1) Main Power Switch / Light Indicator Turns power to the entire unit ON (1) or OFF (0). 9 Rotisserie Ventless Hood Operation Preparation The following conditions must be me...