Log:
Évaluations - 3, GPA: 4 ( )

Instructions Delta, Modèle DTH2450

Fabricant : Delta
Taille : 861.29 kb
Nom Fichier : 0b91abae-6775-2954-c5b0-2b0df7ab7fab.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Reassemble the nozzle to the wand. Tighten securely to prevent leaks. 10. Reconnect wand to gun and turn on water supply. 11. Start pressure washer and place wand into high pressure setting to test. HOW TO CLEAN THE WATER INLET FILTER This screen filter should be checked periodically and cleaned if necessary. 1. Remove filter by grasping end and removing it from water inlet of pump as shown. 2. Clean filter by flushing it with water on both sides. 3. Re-insert filter into water inlet of pump. NOTE: Cone side faces out. Filter Screen NOTE: Do not operate pressure washer without filter properly installed. 11- ENG STORAGE ENGINE Consult the Engine Owners Manual for the manufacturer's recommendations for storage. PUMP The manufacturer recommends using a pump protector/winterizer when storing the unit for more than 30 days and/or when freezing temperatures are expected. If a pump protector/winterizer is not available, *RV antifreeze needs to be run through the pump as outlined in the steps below. NOTE: Using a pump protector/winterizer or *RV antifreeze is to provide proper lubrication to the internal seals of the pump regardless of temperature or environment. 1. Obtain a funnel, six ounces of *RV antifreeze, and 16 - 36 inches of garden hose with a male hose connector attached to one end. Use only RV antifreeze. Any other antifreeze is corrosive and can damage pump. 2. Disconnect spark plug wire. 3. Connect length of garden hose to water inlet of pump. 4. Add *RV antifreeze to hose as shown. 5. Pull engine starter rope slowly several times until antifreeze comes out of high pressure hose connection of pump. 6. Remove garden hose from water inlet of pump. 7. Reconnect spark plug wire. *Windshield washer fluid may also be used PRESSURE WASHER 1. Drain all water from high pressure hose, coil it, and store it in cradle of the pressure washer handle. 2. Drain all water from spray gun and wand by holding spray gun in a vertical position with nozzle end pointing down and squeezing trigger. Store in gun holder. 3. Store chemical hose so it is protected from damage. A00521 12- ENG TROUBLE SHOOTING GUIDE PROBLEM CAUSE CORRECTION Engine will not start (see Engine Manual for further engine troubleshooting) No fuel. Pressure builds up after two pulls on the recoil starter or after initial use. Choke lever in the “No Choke” Add Fuel. Squeeze gun trigger to relieve pressure. Move choke to the “Choke” position. position. Spark plug wire not attached. Attach spark plug wire. Engine ON/OFF switch in OFF position. Place engine ON/OFF switch in on position. Choke lever in the “Choke” Move choke to the “No Choke” position on a “hot” engine or an position. engine that has been exposed to thermal heat for a long period of time. Fuel valve closed. Move the fuel valve lever to the “Open” position. No or low pressure (initial use) Spray wand not in high pressure. Low water supply. Leak at high pressure hose fitting. Nozzle obstructed. Water filter screen clogged. Defective E-Z start valve. Air in hose. Choke lever in the “Choke” position. High pressure hose is too long. See How to Use Spray Wand instructions in the Operation section. Water supply must be at least 5 GPM @ 20 PSI. Tighten fitting. Apply sealant tape if necessary. See Nozzle Cleaning instructions in the Maintenance section. Remove and clean filter. Check with Authorized Warranty Service Center (AWSC.) Turn off the engine, then the water source. Disconnect the water source from the pump inlet and turn the water source on to remove all air from the hose. When there is a steady stream of water present, turn water source off. Re-connect water source to pump inlet and turn on water source. Squeeze trigger to remove remaining air. Move choke to the “No Choke” position. Use high pressure hose under 100 feet. 13- ENG A00521 PROBLEM CAUSE CORRECTION Will not draw chemicals Spray wand not in low pressure. Chemical screen not in cleaning solution. Chemical too thick. Pressure hose is too long. Chemical build up in chemical injector. Chemical filter clogged. See How to Use Spray Wand instructions in the Operation Section. Clean filter. Dilute chemical. Chemical should be the same consistency as water. Lengthen water supply hose instead of high pressure hose. Have parts cleaned or replaced by AWSC. Make sure end of chemical hose is fully submerged into cleaning solution. No or low Worn seal or packing Have replaced by AWSC. pressure Worn or obstructed valves. Have replaced by AWSC. (after period of normal use) Worn unloader piston. Worn E-Z start valve. Have replaced by AWSC. Have replaced by AWSC. Water leaking at gun/spray wand connection Loose hose connection. Worn or broken o-ring. Check and replace. Tighten. Water leaking Loose connections. Tighten. at pump Piston packings worn. Worn or broken o-rings. Pump head or tubes damaged from freezing. Have replaced by AWSC. Have replaced by AWSC. Have replaced by AWSC. Pump Pulsates Nozzle obstructed. See Nozzle Cleaning instruction in th...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories