|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
It receives the volume value of the selected display from the sets and displays it in the slider. (When you cancel the selection or choose Select All, the value returns to the default value 10) 3) Mute On/Off -Turns the mute of the selected display On/Off . When selecting one set at a time, if the selected set is already set to MUTE, you must mark the MUTE display. (If you choose undo the selections or choose Select All, the values return to default settings.) Power Control applies to all displays. The Volume and Mute functions are available only for the displays for which the power status is ON. 5. Input Source Control 1. Click Input Source of the main icons and the Input Source control screen appears. Click Select All or use Check Box to select a display to control. Info Grid shows some basic information necessary to Input Source Control. 1) Power Status -Shows the power status of the current display. 2) Input Source -Shows the Input Source currently in use. 3) Choose Input Source -Change Input Source of the selected display. • RGB 1 : Changes the Input Source of the selected display to RGB 1. • RGB 2 : Changes the Input Source of the selected display to RGB 2. • BNC(RGB 3) : Changes the Input Source of the selected display to RGB 3. • BNC(Component) : Changes the Input Source of the selected display to Component. • Video 1 : Changes the Input Source of the selected display to Video 1. • Video 2 : Changes the Input Source of the selected display to Video 2. Input Source Control applies only to the displays for which the power status is ON. Multiple Display Control (MDC) Info Grid shows some basic information necessary to Image Size Control. 1) Power -Shows the power status of the current display. 2) Aspect -Shows the current Image Size of the display in use. 3) Input Source -Shows the current Input Source of the display in use. 4) Info Grid displays only the displays whose Input Source is RGB 1, 2, 3. 5) When you click Image Size, the RGB 1, 2, 3 tabs first appear. -The Image Size Control button controls Image Size available for RGB 1, 2, 3. 6) Click the Video 1, 2, Component tab to control Image Size for respective Input Source. 7) Click to change Image Size of the selected display. Image Size Control is available only for the displays for which power status is ON. Multiple Display Control (MDC) 6. Image Size Control - Video 1, 2, Component 1. Click Image Size of the main icons and the Image Size control screen appears. Info Grid shows some basic information necessary to Image Size Control. 1) Click the Video 1, 2, Component tab to adjust Image Size for Video 1, 2, Component. Click Select All or use Check Box to select a display to control. 2) Info Grid displays only the display having Video 1, 2, Component as input source. 3) Switch Image Size of the selected display randomly. 4) You can also adjust Image Size for RGB 1, 2, 3 if you click on the RGB 1, 2, 3 tab. 5) Click to change Image Size of the selected display. Image Size Control is available only for the displays for which power status is ON. 7. Time Control 1. Click Time of the main icons and the Time Control screen appears. Info Grid shows some basic information necessary to Time Control. 1) Current Time -Set the current time for the selected display (PC Time). -To change the current time, first change the PC Time. Multiple Display Control (MDC) Current time is equivalent to PC time, If the Current time is not correct set the PC time The shown current time will not be applien before pressing Apply button. 2) On Time Setup -Set the hour, minute, AM/PM of On Time, Status, Source, volume of the selected display. 3) Off Time Setup -Set the hour, minute, and AM/PM, Status for Off Timer of the selected display. 4) Shows the On Timer settings. 5) Shows the Off Timer settings. Time Control is available only for the displays for which the power status is ON. 8. PIP Control - PIP Size 1. Click PIP of the main icons and the PIP control screen appears. Click Select All or use Check Box to select a display to control. Info Grid shows some basic information necessary to PIP Size Control. 1) Power -Shows the power status of the current display. 2) PIP Size -Shows the current PIP Size of the display in use. 3) PIP Source -Shows the current PIP Source of the display in use. 4) When you click PIP, the PIP Size tabs first appear. -The PIP Control button controls PIP Size available for RGB 1, 2, 3, Video 1, 2. 5) Click the PIP Source tab to control PIP Source for respective Input source. 6) Click to change PIP Size of the selected display. • OFF : Turns off the PIP of the selected display. • PIP 1 : Turns on the PIP of the selected display and changes the size to PIP 1. • PIP 2 : Turns on the PIP of the selected display and changes the size to PIP 2. • Double 1 : Turns on the PIP of the selected display and changes the size to Double 1. • Double 2 : Turns on the PIP of the selected display and changes the size to Double 2. PIP Size can be controlled with turning on...
Ce manuel est également adapté pour les modèles :Moniteurs - 323T (5.71 mb)
Moniteurs - S/M403T (5.71 mb)