Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Sony, Modèle CMT-SE9

Fabricant : Sony
Taille : 1.04 mb
Nom Fichier : 4247824111.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


1 Press FUNCTION repeatedly to switch the function to MD. 2 Press MENU/NO. 3 Press . or > repeatedly until “Setup?” appears, then press ENTER. 4 Press . or > repeatedly until “T.Mark Off” (or “T.Mark LSync”) appears, then press ENTER. 5 Press . or > repeatedly until “T.Mark LSync” appears, then press ENTER. “L-SYNC” lights up. MD – Recording continued 47GB 6 Press MENU/NO. To continue recording, follow the procedures described for each type of recording. Other operations To Do this Turn off the Level In step 5, press . or > Synchro Recording repeatedly until “T.Mark Off” Function appears, then press ENTER. Change the trigger After step 3, press . or > lever for Level repeatedly until “LS(T)” Synchro appears, then press ENTER. Recording* Press . or > repeatedly to select the level between –72 dB and 0 dB (in 2 dB steps), press ENTER, then press MENU/NO. * When the recording source is tape or radio program and the track numbers are not marked properly because of noise, set this level higher so that track numbers are marked easily. The factory setting is “–50 dB”. Notes • Track numbers are not marked depending on the track. • Track numbers are not marked automatically if the source sound to be recorded is noisy (e.g., tapes or radio programs). • When recording a CD, track numbers are marked where you paused recording. In addition, the tracks might be recorded as the same single track with a single track number when the same single track of the same CD is recorded repeatedly. Making a space between tracks 3 seconds long automatically —Smart Space Smart Space: Lets you make the blank spaces between tracks 3 seconds long automatically while making a digital recording from a CD. For other types of recording, if the Smart Space Function is on and there is no sound input for about 3 seconds or more (but less than 30 seconds) while recording, the MD deck replaces this silence with a blank of about 3 seconds and continues recording. The Smart Space Function is factory set to on. No sound input for less than 30 seconds Off On Replaced with a blank of 3 seconds and recording continues Auto Cut: When the Smart Space Function is on, if there is no sound input for 30 seconds or more, the MD deck replaces this silence with a blank of about 3 seconds and enters recording pause. No sound input for 30 seconds or more Off On Replaced with a blank of 3 seconds and recording pauses 48GB 1 Press FUNCTION repeatedly to switch the function to MD. 2 Press MENU/NO. 3 Press . or > repeatedly until “Setup?” appears, then press ENTER. 4 Press . or > repeatedly until “S.Space Off” (or “S.Space On”) appears, then press ENTER. 5 Press . or > repeatedly until “S.Space On” appears, then press ENTER. 6 Press MENU/NO. To continue recording, follow the procedures described for each type of recording. To turn off the Smart Space Function In step 5, press . or > repeatedly until “S.Space Off” appears, then press ENTER. Adjusting the recording level When recording on an MD, you can adjust the recording level to the desired volume. You can adjust the recording level not only when making an analog recording, but also when making a digital recording from a CD, etc. 1 Press FUNCTION repeatedly to select the desired source to record. 2 Press REC/REC IT on the MD deck. The MD deck stands by for recording. 3 Start playing the desired source to record. 4 Press MENU/NO to display “Setup?”, then press ENTER. 5 Press . or > repeatedly until “LevelAdjust?” appears, then press ENTER. 6 Press . or > repeatedly to adjust the recording level. Adjust to the optimum level while making sure that “OVER” does not appear in the display at the loudest portion. MD – Recording Adjust the level so as not to light up “OVER”. 7 Press ENTER. 8 Press MENU/NO. 9 Stop playing the sound source. The MD deck stops. To continue recording, follow the procedures described for each type of recording. Tips • You can also adjust the recording level during recording. • Once adjusted, the recording level is maintained until you adjust it again. • You cannot adjust the recording level during CDMD Synchro Recording. 49GB MD Editing Editing tips MD Editing Editing tips Before you start editing You can edit an MD only when: • The MD is recordable. • The MD play mode is Normal Play. Check the following, before editing. 1 Check the tab of the MD to be edited. Slide the tab to close the slot. If the MD is protected, you cannot edit the MD. 2 Press PLAY MODE repeatedly until both “SHUF” and “PGM” disappear. You can edit the MD only in Normal Play mode. You cannot edit the MD in Shuffle or Program Play mode. To quit while editing Press MENU/NO. After editing Press Z MD on the MD deck to remove the MD or press ?/1 (power) to turn off the system. “TOC” starts flashing. The TOC is updated and editing is completed. Before pulling out the mains lead MD editing is completed when the MD Table of Contents (TOC) is updated. The TOC is updated when you eject the MD or press ?/1 to turn off the system. Do not ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories