Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Roland, Modèle GT-8

Fabricant : Roland
Taille : 3.68 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


TRANSMITTED DATA ■CHANNEL VOICE MESSAGE 1. RECOGNIZED RECEIVE DATA •Control Change Status Second Third BnH ccH vvH ■CHANNEL VOICE MESSAGE n = MIDI Channel Number: cc = Controller Number: •Control Change Status Second BnH ccH n = MIDI Channel Number: cc = Controller Number: Third vvH OH - FH (ch.l - ch.16) ООН, 20H (0,32) 01H - 1FH (1 - 31) 40H - 5FH (64 - 95) 00H - 7FH (0 -127) * Control numbers 00H and 20H are recognized as Bank Select messages. 00H: For values of 03H or lower, the Program Change Map will be switched according to the value. For values of 04H or higher, the received data will be ignored. 20H: The received data will be ignored, regardless of the value. * By specifying this as a Source for "Assign Variable" (owner's manual p. 57) you can use these messages to control a Target. •Program Change Status Second CnH ppH n = MIDI Channel Number: pp = Program Number: OH - FH (ch.l - ch.16) 00H - 7FH (No.l - No. 128) Patches will be selected according to the program number that is received. There are three Program Change Maps which are referenced when selecting programs, and these are switched by Bank Select messages. ■SYSTEM REALTIME MESSAGE •Timing Clock Status F8H •Active Sensing Status FEH * When an Active Sensing message is received, the interval of all subsequent messages will begin to be monitored. If an interval greater than 400 msec, between messages, the display will indicate "MIDI Off Line!" OH - FH (ch.l - ch.16) ООН, 20H (0, 32) 01H - 1FH (1 - 31) 21H - 5FH (33 - 95) 00H - 7FH (0 - 127) If you set up a system parameter "MIDI PC OUT" for "On," Bank Select (00H, 20H) is transmitted when switching patch. If you set up a control change number at a system parameter "MIDI EXP OUT," "MIDI EXP SW OUT," "MIDI CTL OUT," "MIDI SubCTLl OUT," and "MIDI SubCTL2 OUT" control change information is transmitted when operating the EXP pedal, EXP pedal switch, CTL pedal, and external EXP pedal/Foot switch. •Program Change Status Second CnH ppH n = MIDI Channel Number: pp = Program Number: OH - FH (ch.l - ch.16) 00H - 7FH (No.l - No. 128) If you set up a system parameter "MIDI PC Out" for "On," program change information is transmitted when switching patch. ■SYSTEM REALTIME MESSAGE •Start Status FAH •Stop Status FCH ■SYSTEM EXCLUSIVE MESSAGE Status Data Byte Status F0H iiH ddH... eeH F7H F0H = System Exclusive ii = Manufacturer ID: 41H (Roland) dd... ее = Data: 00H - 7FH (0 -127) F7H = EOX (End of Exclusive/System common) For more details, please refer to "Roland Exclusive Message." ■SYSTEM EXCLUSIVE MESSAGE Status Data Byte Status F0H iiH ddH... eeH F7H F0H = ii = System Exclusive Manufacturer ID: 41H (Roland) dd... ее = Data: 00H - 7FH (0 -127) F7H = EOX (End of Exclusive/System common) * For more details, please refer to "Roland Exclusive Message." Copyright ©2005 BOSS CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the written permission of BOSS CORPORATION. i MIDI Implementation •MIDI Machine Control (MMC) FOH 7FH 7FH 06H com F7H FOH = 7FH = 7FH = 06H = com = F7H = System Exclusive ID Number (Universal Realtime Message) Device ID (Broadcast) Sub ID#1 (Machine Control Command) Sub ID#2 (MMC Command) EOX (End of Exclusive/System common) * "com" (MMC Command) that I transmit with GT-8 is following. 01H 02H Stop Play 3. EXCLUSICE COMMUNICATION On the GT-8, exclusive messages can be used as follows. - Transmit/receive GT-8 system/ patch data. The model ID for GT-8 exclusive messages is 00H 00H 06H, and you can set up the device ID at 00H-1FH. ■ONE WAY COMMUNICATION •Request Data 1 RQ1 (11H) FOH 41H dev 00H 00H 06H 11H aaH bbH ccH ddH ssH ttH uuH vvH sum F7H FOH = Exclusive Status 41H = Manufacturer ID (Roland) dev = Device ID (Dev=OOH-l FH) 00H = Model ID MSB (GT-8) 00H = Model ID (GT-8) 06H = Model ID LSB (GT-8) 11H = Command ID (RQ1) aaH = Address MSB bbH = Address ccH = Address ddH = Address LSB ssH = Size MSB ttH = Size uuH = Size vvH = Size LSB sum = Checksum F7H = EOX (End of System E This message can only be received, and is not transmitted from the GT-8. When transmitting large Size values spanning fragmented addresses, the data can be transmitted only to those addresses that are contiguous. •Inquiry Message Oldentity Request FOH 7EH ЮН 06H 01H F7H FOH = 7EH = dev = 06H = 01H = F7H = Exclusive Status ID Number Device ID (Dev=00H-lFH) Sub ID#1 Sub ID#2 EOX (End of System Exclusive) * The 7FH (Broadcast) device ID is also supported. * When an Identity Request is received, the GT-8 will transmitted the following Identity Reply. Oldentity Reply FOH 7EH ЮН 06H 02H 41H 06H 02H ООН ООН ООН ООН ООН ООН F7H F0H= Exclusive Status 7ЕН= ID Number (Universal Non-realtime Message) dev = Device ID (Dev=00H-lFH) 06H= Sub ID#1 02H= Sub ID#2 41 H= ID Number (Roland) 06H 02H= Device Family Code ООН 00H= Device Family Number Code ООН ОО...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories