Log:
Évaluations - 2, GPA: 3 ( )

Instructions Roland, Modèle JSQ-60

Fabricant : Roland
Taille : 683.37 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


By using the REST and TIE Buttons, fairly complicated music pieces can be loaded. Therefore, you can chose either Step Load or Real time load mode. • It is possible to overdub on the existing data up to three times in Real time mode. • The Patch Shift of the Juno-60 or Patch Preset of the JP-8 can be memorized. • Tape Interface allows loading the data in the JSQ-60's memory onto an ordinary audio tape for storage and later retrieval. Features....................................................P- 2 Important Notes Power Supply ..............................................P- 3 Location..................................................P- 3 Cleaning..................................................P- 3 Others ...................................................p- 3 Fi ont Panel..................................................P. 4 Panel Description..............................................P. 5 Connection..................................................P. 6 Load and Playback.............................................P. 7 Real Time Load.............................................P. 7 Play/Repeat................................................P. 8 Tempo/Me tionome...........................................P. 8 Step Load.................................................P- 9 Edit....................................................P- 1 1 Continue Load.............................................P. 12 Overdub.................................................P. 13 Tape Interface...............................................P. 14 Save....................................................P. 1 5 Verify ..................................................P- 15 Load ...................................................P- 16 Application.................................................P. 16 Patch Shift ...............................................P. 1 7 Patch Preset..................................... ......P. 17 Start/Stop.............................................. ■ • P- 18 SYNC...................................................P- 18 MIDI .....................................................P. 18 Error.....................................................P. 19 Specifications ................................................P. 20 • Two Sync Out Jacks (DIN) allowing synchronization with another sequencer or the rhythm machine featuring Sync In, • Up to 2000 notes can be written into the JSQ-60, and the Memory Indicator tells you how much memory has been consumed so far. 2 IMPORTANT POWER SUPPLY LOCATION CLEANING OTHERS • The JSQ-60 adapts AC powered system. Be sure to use the supplied AC Adaptor Using any other adaptor will cause malfunction or even break down. • Do not turn the JSQ-60 on, before connecting the AC Adaptor to it. • This unit might not work properly if turned on immediately after turned off. If this happens, simply turn it off again and turn it on a few seconds later. • Before setting up the JSQ-60 with an external synthesizer, be sure to turn both of them off. • Using the JSQ-60 near a neon or fluorescent lamp may cause noise interference, If so, change the angle or position of the JSQ-60. • Avoid using the JSQ-60 in extreme heat or humidity or where it may be affected by dust. • Use a soft cloth and clean only with a mild detergent. • Do not use solvents such as paint thinner. • If the AC Adaptor is connected, turning the Power Switch off does not erase the data in memory, but in about a day after the AC Adaptor is disconnected, its data will be completely erased. So it may be a good idea to load all data onto a cassette tape for precaution. • Do not pull the DCB cord hard. 3 © Power Switch ô I Reset/Verify Button ) Mode Switch ) Tempo Knob Metronome Level Switch : Memory Indicators POWER MODE PLAY ONLY (PROTECT) TEMPO LOAD/ PLAY METRONOME LEVEL HIGH -LOW -OFF MEMORY 25 5 0 75 90 FULL SLOW LOAD MODE over ; 4/4 3/4 DUB . I—I I—I I—i I—I I—1 H=l- RESET LOAD STOP PLAY REPEAT PLAV REALTIME Ô Ô O MODE SELECT @ Repeat/Play Switch Play/Save Button I Stop Button (7) Load Button > Load Mode Indicators ' Measure End Button Rest Button I Tie Button @ Load Mode Selector Button 4 © Power Switch Pushing this switch on will light up the Indicator and turns the JSQ-60 on. @ Mode Switch The JSQ-60 includes two modes for sequencer, and a mode for loading the sequencer data onto a tape as follows. • Play Only (Protect) mode This mode is to playback the data you have written into the-sequencer, but writing is not possible in this mode. To protect the data from accidental loss, always turn the JSQ-60 into this mode except when loading. • Load/Play mode This mode is for loading, playing back, editing and overdubbing. • Tape mode This mode is for saving sequencer data onto a tape, and later loading it back to the sequencer. < NOTE > Be sure that the JSQ-60 is not running while changing the modes. The data will be erased if ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories