Log:
Évaluations - 5, GPA: 4.2 ( )

Instructions Roland, Modèle M-160MKII

Fabricant : Roland
Taille : 838.73 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


All other servicing should be referred to qualified service personnel. SAVE THESE INSTRUCTIONS f-For the U.K.- WARNING: THIS APPARATUS MUST BE EARTHED IMPORTANT: THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE. GREEN-AND-YELLOW: EARTH, BLUE: NEUTRAL, BROWN: LIVE As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings indentifying the terminals ii\ your plug proceed as follows: The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol ©or coloured GREEN or GREEN-AND-YELLOW. The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK. The wire which is coloured BROWN must be connected to the terminal which is marked with the letter Lor coloured RED. The product which is equipped with a THREE WIRE GROUNDING TYPE AC PLUG must be grounded. 2 Thank you for purchasing the Roland M-160II. The M-160II is a compact yet versatile and high-quality 16 channel line mixer. To get the most out of your M-160II, please read this owner's manual carefully and keep it handy so you can refer to it as necessary. ■FEATURES • 4U rack-mount 16-channel mixer with line inputs. • Wide range of input levels: channels 1 and 2 are mic level (-50 dBm), and the others are adjustable in a range from -30dBm to professional line level (+4 dBm). • Four independent SEND and stereo RETURN jacks, with switchable pre/post fader AUX jacks that can be used in effects loops or for monitoring. • Separate MONITOR OUT and MASTER OUT jacks allowing independent volume control of these signals. • A MONITOR IN jack lets you hear the tempo click from a sequencer through the MONITOR OUT jacks or headphone jack (PHONES). • New signal routing design and components for optimum sound quality, in the tradition of Roland M-series mixers. • Balanced XLR type connectors for professional use. • Peak Signal Indicators for each channel, and a Peak Meter and Pre-Fader Indicator in the Master section for fast and accurate monitoring of levels. Copyright © 1992 by ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the permission of ROLAND CORPORATION. 3 TABLE OF CONTENTS ■ Features.............................................................. 3 ■ Important Notes............................................ 5 |T| Block Diagram and Signal Flow..... 7 1. Channel Section........................................... 7 2. Master Section............................................. 7 [Inputs] a. Return............................................................ 7 b. Monitor In..................................................... 7 [Outputs] c. Master Out................................................... 8 d. Monitor Out.................................................. 8 e. Effect Send................................................... 8 f. AUX Send..................................................... 8 g. Phones........................................................... 8 [~2] Panel Descriptions.................................... 9 1. Channel Section........................................... 9 2. Master Section.............................................10 3. Rear Panel......................................................12 [31 Connections and Operation................14 ■ Basic Procedure...........................................14 1. Basic Setup with a Microphone, Electronic Musical Instrument, Audio Equipment, etc................................14 ■ Mixing a Microphone, Electronic Musical Instrument, Audio Equipment, etc..........14 2. Setup Example with Effects Device..........16 ■ Effects processing with a delay, reverb, etc....................................................16 3. Monitoring (Foldback) with AUX outputs......................................17 4. Monitoring using the MONITOR OUT.......18 [T1 Level Diagram.............................................19 p5] Input/Output Standard..........................20 fel Specifications...............................................21 Information..............................................................22 4 ■ Important Notes In addition to the following: [Power Supply] [Placement] [Maintenance] items listed under Safety Precautions on page 2, please read and adhere to the • When making any connections with other devices, always turn off the power to all equipment first; this will help prevent damage or malfunction. • Do not use this unit on the same power circuit with any device that will generate line noise, such as a motor or variable lighting system. • Using the unit near power amplifiers (or other equipment containing large transformers) may induce hum. • This unit may interfere with radio and television reception. Do not use this unit in the vicinity of such rece...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories