Log:
Évaluations - 5, GPA: 4.4 ( )

Instructions Roland, Modèle MT-90S

Fabricant : Roland
Taille : 86.82 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


2000 Model: MT-90s MIDI IMPLEMENTATION Version: 1.00 MUSIC PLAYER Date: Oct. 27. 2000 Model: MT-90s MIDI IMPLEMENTATION Version: 1.00 .Modulation (Controller number 1) Section 1. Receive data Status 2nd bytes 3rd byte BnH 01H vvH Channel Voice Messages n = MIDI channel number: 0H-FH (ch.1-ch.16) Note off vv = Modulation depth: 00H-7FH (0-127) Status 2nd byte 3rd byte 8nH kkH vvH * Not received when Rx.MODULATION = OFF. (Initial value is ON) 9nH kkH 00H * The resulting effect is determined by System Exclusive messages. With the initial settings, this is Pitch Modulation Depth. n = MIDI channel number: 0H-FH (ch.1-ch.16) .Portamento Time (Controller number 5) kk = note number: 00H-7FH (0-127) vv = note off velocity: 00H-7FH (0-127) Status 2nd bytes 3rd byte BnH 05H vvH * For Drum Parts, these messages are received when Rx.NOTE OFF = ON for each Instrument. n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Portamento Time: 00H-7FH (0-127), Initial value = 00H (0) * The velocity values of Note Off messages are ignored. Note on * This adjusts the rate of pitch change when Portamento is ON or when using the Portamento Control. A value of 0 results in the fastest change. Status 2nd bytes 3rd byte 9nH kkH vvH .Data Entry (Controller number 6, 38) Status 2nd bytes 3rd byte n = MIDI channel number: 0H-FH (ch.1-ch.16) BnH 06H mmH kk = note number: 00H-7FH (0-127) BnH 26H llH vv = note on velocity: 01H-7FH (1-127) n = MIDI channel number: 0H-FH (ch.1-ch.16) * Not received when Rx.NOTE MESSAGE = OFF. (Initial value is ON) mm, ll = the value of the parameter specified by RPN/NRPN * For Drum Parts, not received when Rx.NOTE ON = OFF for each Instrument. .Volume (Controller number 7) Polyphonic Key Pressure Status 2nd bytes 3rd byte BnH 07H vvH Status 2nd bytes 3rd byte AnH kkH vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Volume: 00H-7FH (0-127), Initial Value = 64H (100) n = MIDI channel number: 0H-FH (ch.1-ch.16) kk = note number: 00H-7FH (0-127) * Volume messages are used to adjust the volume balance of each Part. vv = key pressure: 00H-7FH (0-127) * Not received when Rx.VOLUME = OFF. (Initial value is ON) * Not received when Rx.POLY PRESSURE (PAf) = OFF. (Initial value is ON) .Pan (Controller number 10) * The resulting effect is determined by System Exclusive messages. With the initial Status 2nd bytes 3rd byte settings, there will be no effect. BnH 0AH vvH Control Change n = MIDI channel number: 0H-FH (ch.1-ch.16) * When Rx.CONTROL CHANGE = OFF, all control change messages except for Channel vv = pan: 00H-40H-7FH (Left-Center-Right), Mode messages will be ignored. Initial Value = 40H (Center) * The value specified by a Control Change message will not be reset even by a Program Change, etc. * For Rhythm Parts, this is a relative adjustment of each Instrumentspansetting.' * Not received when Rx.PANPOT = OFF. (Initial value is ON) .Bank Select (Controller number 0, 32) Status 2nd bytes 3rd byte .Expression (Controller number 11) BnH 00H mmH Status 2nd bytes 3rd byte BnH 20H llH BnH 0BH vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) n = MIDI channel number: 0H-FH (ch.1-ch.16) mm, ll = Bank number: 00H, 00H-7FH, 7FH (bank.1-bank.16384), vv = Expression: 00H-7FH (0-127), Initial Value = 7FH (127) Initial Value = 00 00H (bank.1) * It can be used independently from Volume messages. Expression messages are used for * Not received when Rx.BANK SELECT = OFF. musical expression within a performance; e.g., expression pedal movements, crescendo * "Rx.BANK SELECT" is set to OFF by "GM1 System On," and Bank Select message will be and decrescendo. ignored. * Not received when Rx.EXPRESSION = OFF. (Initial value is ON) * "Rx.BANK SELECT" is set to ON by "GM2 System On." .Hold 1 (Controller number 64) * "Rx.BANK SELECT" is set to ON by power-on Reset or by receiving "GS RESET." Status 2nd bytes 3rd byte * When Rx.BANK SELECT LSB = OFF, Bank number LSB (llH) will be handled as 00H BnH 40H vvH regardless of the received value. However, when sending Bank Select messages, you have to send both the MSB (mmH) and LSB (llH, the value should be 00H) together. n = MIDI channel number: 0H-FH (ch.1-ch.16) * Bank Select processing will be suspended until a Program Change message is received. vv = Control value: 00H-7FH (0-127) * The GS format "Variation number" is the value of the Bank Select MSB (Controller number 0) expressed in decimal. * Not received when Rx.HOLD1 = OFF. (Initial value is ON) * Some other GS devices do not recognize the Bank Select LSB (Controller number 32). .Portamento (Controller number 65) Status 2nd bytes 3rd byte BnH 41H vvH n = MIDI channel number: 0H-FH (ch.1-ch.16) vv = Control value: 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON * Not received when Rx.PORTAMENTO = OFF. (Initial value is ON) Copyright © 2001 ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION. .Sostenuto (Controller number 66) Status 2nd bytes 3rd byte ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories