Log:
Évaluations - 4, GPA: 4.3 ( )

Instructions Roland, Modèle SP-404

Fabricant : Roland
Taille : 2.64 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Par ce dispositif a également d'autres instructions :

Facilité d'utilisation


Check the connected equipment and the connections. (p. 10) If you’re using a memory card, is it inserted correctly? Check the memory card. (p. 11) If you’re trying to play a sample, is the sample’s pad lit? When you press the pad of a sample, that sample will sound. If a pad does not light when you press it, no sample has been assigned to that pad. A Specific Sample Fails to Sound Could the sample level be lowered? Adjust the level of the sample. (p. 29) Could the effect level be lowered? For some types of effects, an effect control knob adjusts the level. For details on the effect types and control knobs, refer to p. 20. Sound from a Device Connected to LINE IN Is Inaudible or Too Soft Is [EXT SOURCE] lit? In order to hear the sound from the line inputs, you must press [EXT SOURCE] so its LED is turned on. Could the level of the external input be lowered? Turn the CTRL 3 knob to adjust the level appropriately. (p. 17) Could the volume of the device connected to LINE IN be lowered? Adjust the level appropriately. Are the audio cables connected correctly? Check the connections. (p. 10) Could the audio cables be broken? Could you be using an audio cable with a built-in resistor? Use connection cables that do not contain resistors (such as one from the Roland PCS series). Sound from the Mic Is Inaudible or Too Soft Is [EXT SOURCE] lit? In order to hear the sound from the mic input, you must press [EXT SOURCE] so its LED is turned on. Is [MIC] lit? In order to hear the sound from the mic input, you must press [MIC] so it’s lit. Could the external input level be lowered? Turn the CTRL 3 knob to adjust the level appropriately. (p. 17) Could the level of the mic connected to MIC IN or the SP-404’s internal mic be lowered? Turn the MIC LEVEL knob to adjust the level appropriately. Is the mic cable connected correctly? Check the connections. (p. 10) Could the mic cable be broken? Appendices Appendices Could you be out of memory? If you are out of memory, “FUL” (Memory Full) appears in the display when you attempt to sample. Delete unwanted samples to increase the amount of free memory. (p. 27) If you’re sampling into sample banks C–J, is the memory card inserted correctly? Check the memory card. (p. 11) If you’re sampling into sample banks C–J, has the memory card been formatted by the SP404? Format the memory card on the SP-404. (p. 38) Could samples already be assigned to all pads? You can’t sample if there are no vacant pads. Delete unwanted samples to free up some of the pads. (p. 27) Could [PATTERN SELECT] be lit? If [PATTERN SELECT] is lit, you will be selecting patterns; you cannot sample in this state. Press [PATTERN SELECT] so its LED is switched off. Could [DEL] be lit or blinking? If [DEL] is lit or blinking, you are deleting samples; you cannot sample in this state. Sampled Sound Is Noisy or Distorted Is the input level appropriate? If the input level is too high, the sampled sound will be distorted. If the input level is too low, the sampled sound will be noisy. Adjust the level so that the PEAK indicator lights occasionally. Are the effect settings appropriate? Some types of effect boost the level higher than the original sample, or intentionally distort the sound. Some effects may also emphasize any noise that is present. Try turning the effect off temporarily to see whether the original sample itself contains noise or distortion. Then change the effect settings as appropriate. Could you be playing multiple samples simultaneously? Even if the level of each individual sample is appropriate, playing multiple samples simultaneously may raise the overall level to a point where distortion occurs. Lower the level of each sample so that distortion does not occur. Problems with Memory Data Is Not Correctly Saved in Internal Memory You may have turned off the power while data was being written into internal memory (while the dot in the display was blinking). The lost data cannot be recovered. In this case, it is possible that all of the data in internal memory has been damaged. Since there is a danger that the SP-404 will not operate correctly if you continue using it in this state, please initialize the internal memory. (p. 43) * All data in the SP-404’s internal memory will be lost when you initialize. Data Is Not Correctly Saved in a Memory Card You may have turned off the power while data was being written into the memory card (while the dot in the display was blinking). The lost data cannot be recovered. In this case, it is possible that all of the data in the memory card has been damaged. Since there is a danger that the SP-404 will not operate correctly if you continue using the card in this state, please format the memory card. (p. 38) * All data in the memory card will be lost when you format it. Memory Card Is Not Detected When You Insert It Can’t Select Data from the Memory Card Is the memory card inserted correctly? Check the memory card. (p. 11) Is the memory card the correct type? The SP-404 can ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories