|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
This manual contains descriptions of the added and changed specifications. Mounting limitation for two-space Premium Rack processor (Reference Manual, p. 127) A two-space Premium Rack processor (U76) can be mounted only in an odd-numbered rack. Addition of PATCHING indicator (Reference Manual, p. 136) A PATCHING indicator has been added to the Function Access Area. The PATCHING indicator appears when a DANTE INPUT PATCH setting or an I/O RACK OUTPUT PATCH setting is changed. While this indicator is lit, a DANTE INPUT PATCH setting or an I/O RACK OUTPUT PATCH setting cannot be changed continuously. Using a Premium Rack with the MIDI PROGRAM CHANGE popup window (Reference Manual, p. 148) The procedure for using a Premium Rack has changed for the MIDI PROGRAM CHANGE popup window. If you have selected PREMIUM RACK in the TYPE field, you can select the rack number in the DESTINATION field and the library number in the LIBRARY NUMBER field. The DESTINATION field and LIBRARY NAME field also appear when you select SCENE in the TYPE field. Addition of options when loading a settings file (Reference Manual, p. 170) In the SAVE/LOAD popup window, you can select whether or not to load Dante settings while loading a settings file. WITH DANTE SETUP AND I/O RACK button When you turn off the button, settings related to DANTE SETUP and the I/O rack are excluded when the settings file is loaded. NOTE The SECONDARY PORT and CONSOLE ID settings in the DANTE SETUP popup window are not changed, even if the WITH DANTE SETUP AND I/O RACK button is on. Display of version information (Reference Manual, p. 184) Version information has been added to the SETUP screen, which is accessed by pressing the SETUP button in the Function Access Area. The following items appear. BATTERY: Status of the internal battery (Normally YES; LOW or NO when the battery runs down) POWER SUPPLY: Whether the currently running power supply is internal (INT) or PW800 (EXT) MAIN: Version number of main CPU SUB: Version number of sub CPU DANTE: Version number of DANTE module Operation when changing NETWORK settings (Reference Manual, p. 191) After changing settings in the NETWORK popup window, which is accessed by pressing the SETUP button in the Function Access Area, then pressing the NETWORK button, the CL series must be restarted. NOTE The NETWORK setting is not changed, even if the CL series is initialized. Operation when changing settings in the DANTE SETUP popup window (Reference Manual, p. 198) . When settings have been changed in the DANTE SETUP popup window, the ACCESS indicator lights while the setting changes are stored on the unit. The ACCESS indicator lights when settings for the following are changed. - Parameters in the DANTE SETUP screen - Parameters in the WORD CLOCK screen - Patch settings, Library operations, and AUTO SETUP button operations in the DANTE INPUT PATCH popup window - Parameters in the OUTPUT tab of the I/O RACK screen In order to apply changes to settings in the DANTE...
Ce manuel est également adapté pour les modèles :Instruments de musique - CL3 (245.88 kb)
Instruments de musique - CL5 (245.88 kb)