|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
Control No. Channel Control No. Channel 1 CH INPUT 1 36 CH INPUT 36 2 CH INPUT 2 37 CH INPUT 37 3 CH INPUT 3 38 CH INPUT 38 4 CH INPUT 4 39 CH INPUT 39 5 CH INPUT 5 40 CH INPUT 40 6 CH INPUT 6 41 CH INPUT 41 7 CH INPUT 7 42 CH INPUT 42 8 CH INPUT 8 43 CH INPUT 43 9 CH INPUT 9 44 CH INPUT 44 10 CH INPUT 10 45 CH INPUT 45 11 CH INPUT 11 46 CH INPUT 46 12 CH INPUT 12 47 CH INPUT 47 13 CH INPUT 13 48 CH INPUT 48 14 CH INPUT 14 49 ST CH INPUT 1 15 CH INPUT 15 50 ST CH INPUT 2 16 CH INPUT 16 51 ST CH INPUT 3 17 CH INPUT 17 52 ST CH INPUT 4 18 CH INPUT 18 53 CH INPUT 49 19 CH INPUT 19 54 CH INPUT 50 20 CH INPUT 20 55 CH INPUT 51 21 CH INPUT 21 56 CH INPUT 52 22 CH INPUT 22 57 CH INPUT 53 23 CH INPUT 23 58 CH INPUT 54 24 CH INPUT 24 59 CH INPUT 55 25 CH INPUT 25 60 CH INPUT 56 26 CH INPUT 26 61 G1/A7 OUT 27 CH INPUT 27 62 G2/A8 OUT 28 CH INPUT 28 63 G3/A9 OUT 29 CH INPUT 29 64 G4/A10 OUT 30 CH INPUT 30 65 G5/A11 OUT 31 CH INPUT 31 66 G6/A12 OUT 32 CH INPUT 32 67 G7/A13 OUT 33 CH INPUT 33 68 G8/A14 OUT 34 CH INPUT 34 69 STEREO OUT 35 CH INPUT 35 70 MONO/C OUT Control No. Mute group 105 MUTE GROUP 1 106 MUTE GROUP 2 107 MUTE GROUP 3 108 MUTE GROUP 4 109 MUTE GROUP 5 110 MUTE GROUP 6 111 MUTE GROUP 7 112 MUTE GROUP 8 36 M2500—Owner’s Manual The Scene Memory function M2500—Owner’s Manual 37 Mute groups By setting the Utility mode item oP (recall operation) to “ ,” you can use the on/off settings of scene memory numbers 1–8 as “mute groups.” In this case, the DIRECT RECALL 1–8 switches will function as “mute group switches” that control mute groups. The differences in operation between the “ ” (direct recall) and “ ” (mute group) settings of the oP (recall operation) item are explained below. Direct recall If you press the DIRECT RECALL 1 switch to recall scene memory 1, and then press the DIRECT RECALL 3 switch to recall scene memory number 3, the on/off settings of scene memory number 1 will be cancelled, and replaced by the on/off settings of scene memory number 3. Mute group If you press the DIRECT RECALL 1 switch to recall scene memory number 1, and then press the DIRECT RECALL 3 switch to recall scene memory number 3, the mute (off) settings of scene memory number 1 will remain, and only the mute settings of scene memory number 3 will be added. (At this time, both DIRECT RECALL switches 1 and 3 will be on.) If you then press the DIRECT RECALL 1 switch once again, the mute settings of scene memory number 3 will remain, and the mute settings of scene memory number 1 will be cancelled. Scene memory number 1 MUTE (OFF) ON ON MUTE (OFF) ON Scene memory number 3 On/off settings of memory number 1 are recalled In the case of Direct Recall Switch to the on/off settings of memory number 3 ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON OFF ON ON OFF ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON MUTE (OFF) ON ON ON MUTE (OFF) ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON OFF ON ON OFF OFF ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Mute group 1 (scene memory number 1) MUTE (OFF) ON ON MUTE (OFF) ON Mute group 3 (scene memory number 3) The mute settings of memory number 1 are recalled ..In the case of Mute Group The mute settings of memory number 3 are added ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON MUTE ON ON MUTE ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON MUTE (OFF) ON ON ON MUTE (OFF) ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON MUTE ON ON MUTE MUTE ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 The mute settings of memory number 1 are cancelled ON ON MUTE MUTE ON/EDIT CHECK ON ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON ON/EDIT CHECK ON 1 2 3 4 5 6 7 8 The Scene Memory function The Scene Memory function About the local control cir 1. In a scene memory number 1–8, store the mute (off) settings of the channels that you wish to cuit use as a mute group. In the unlikely event that the system of the M2500 2. Press the UTILITY switch to move to Utility experiences a malfunction so that the scene memory mode, select the oP (recall operation) item, and circuit cannot be used, it will automatically switch to set its value to “ .” (For details on procedure the local control circuit. When the local control cir in Utility mode, refer to page 34.) cuit is operating, the MEMORY display will go dark, Now scene memory numbers 1–8 can be used as and it will not be possible to operate the scene memmute groups, and the DIRECT RECALL 1–8 switches ory switches. However, the ON/EDIT switches of the will function as mute group switches. input channels and output channels will function as conventional on/off switches, so that you can con 3. Press and ...
Ce manuel est également adapté pour les modèles :Instruments de musique - M2500-24 (1.65 mb)
Instruments de musique - M2500-32 (1.65 mb)
Instruments de musique - M2500-40C (1.65 mb)
Instruments de musique - M2500-48C (1.65 mb)