|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
This is not received when MIDI PROGRAM CHANGE TABLE = OFF. When an On message is received, the controller values will be reset, and the voice number will be 09.REVERB and CHORUS settings will be the settings of voice number 09. 3.1.3 XG Native Parameter Changes 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0001nnnn 1n Device No. 01001100 4C XG Model ID 0aaaaaaa aa Address High 0aaaaaaa aa Address Mid 0aaaaaaa aa Address Low 0ddddddd dd Data | | 11110111 F7 End of Exclusive Parameters with a Data Size of 2 or 4 transmit data of the corresponding size. 3.1.3.1 XG Sytem On 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0001nnnn 1n Device No. 01001100 4C XG Model ID 00000000 00 Address High 00000000 00 Address Mid 01111110 7E Address Low 00000000 00 Data 11110111 F7 End of Exclusive This is not received when MIDI PROGRAM CHANGE TABLE = OFF. When an On message is received, the controller values will be reset, and the voice number will be 09. REVERB and CHORUS settings will be the settings of voice number 09. 3.1.3.2 XG System Data parameter change Refer to tables <1-1> and <1-2>. 3.1.3.3 Multi Effect1 Data parameter change Refer to tables <1-1> and <1-3>. 3.1.3.4 Part Data parameter change Refer to tables <1-1> and <1-4>. 3.1.4 P50-m Native Parameter Changes 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0001nnnn 1n Device No. 01010101 55 P50-m Model ID 0aaaaaaa aa Address High 0aaaaaaa aa Address Mid 0aaaaaaa aa Address Low 0ddddddd dd Data | | 11110111 F7 End of Exclusive Parameters with a Data Size of 2 or 4 transmit the corresponding amount of data. 3.1.4.1 P50-m System Data parameter change Refer to tables <2-1> and <2-2>. 3.1.4.2 Remote Switch Refer to tables <2-1> and <2-3>. 3.1.5 Other parameter changes 3.1.5.1 Master Tuning 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0001nnnn 1n Device No. 00100111 27 Model ID 00000001 30 Sub ID2 00000000 00 00000000 00 0mmmmmmm mm Master Tune MSB 0lllllll ll Master Tune LSB 0ccccccc cc 11110111 F7 End of Exclusive This message modifies the pitch of all channels at once. 3.2 Bulk Dump This instrument receives the following bulk data. [ XG NATIVE ] 1) XG System Data 2) Multi Effect1 Data 3) Part Data [ P50-m NATIVE ] 1) P50-m System data 3.2.1 XG Native Bulk Dump 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0000nnnn 0n Device No. 01001100 4C XG Model ID 0bbbbbbb bb Byte Count 0bbbbbbb bb Byte Count 0aaaaaaa aa Address High 0aaaaaaa aa Address Mid 0aaaaaaa aa Address Low 00000000 00 Data | | 0ccccccc cc Check-sum 11110111 F7 End of Exclusive For the Address and Byte Count, refer to the accompanying tables. Check sum is the value which produces a lower 7 bits of zero when the Start Address, Byte Count, and Check-sum itself are added. 36 SOUND LISTS & MIDI DATA 513 bytes or more shall not be received at one time. Thus, 5.2 When MIDI OUT=ot2 513 bytes or more shall not be received at one time. Thus, 5.2 When MIDI OUT=ot2 3.2.1.1 XG System Data bulk dump Refer to tables <1-1> and <1-2>. 3.2.1.2 Multi Effect1 Data bulk dump Refer to tables <1-1> and <1-3>. 3.2.1.3 Part Data bulk dump Refer to tables <1-1> and <1-4>. 3.2.2 P50-m Native bulk dump 11110000 F0 Exclusive status 01000011 43 YAMAHA ID 0000nnnn 0n Device No. 01010101 55 P50-m Model ID 0bbbbbbb bb Byte Count 0bbbbbbb bb Byte Count 0aaaaaaa aa Address High 0aaaaaaa aa Address Mid 0aaaaaaa aa Address Low 00000000 00 Data | | 0ccccccc cc Check-sum 11110111 F7 End of Exclusive For the Address and Byte Count, refer to the accompanying tables. Check sum is the value which produces a lower 7 bits of zero when the Start Address, Byte Count, and Check-sum itself are added. 513 bytes or more shall not be received at one time. Thus, if a dump request for 513 bytes or more is received, the data must be divided into packets of 512 bytes or less, and the packets transmitted with an appropriate time interval (120 msec or more). 3.2.2.1 P50-m System Data bulk dump Refer to tables <2-1> and <2-2>. 4. Realtime Messages 4.1 Active Sensing Once FE has been received, failure to receive subsequent MIDI messages for an interval greater than approximately 300 msec will cause the same processing to be performed as when SOUND OFF, ALL NOTE OFF, and RESET ALL CONTROLLERS are received, and then the instrument will return to the status of not having received FE. 5. MIDI thru out MIDI data that is received is re-transmitted (thru out) in the following 2 modes. 5.1 When MIDI OUT=ot1 Data received at MIDI IN is re-transmitted (thru out) without change. Data other than Key ON/OFF messages of the receive channel specified by MIDI CH will be re-transmitted (thru out). However if the Receive Channel is set to ALL, or if the voice number is 29 (Silence), all data will be re-transmitted (thru out) without change. When the setting is changed from ot1 to ot2, the change is made simply, without performing any management of notes which may be currently on. In some cases this can cause problems; switching the setting to ot2 while notes...