Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Pentair, Modèle HP 400, HP 600, HP 800, HP 1000, HP 230

Fabricant : Pentair
Taille : 422.14 kb
Nom Fichier : 8e9933e6-b597-43ab-a02d-e403bb4e3d90.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Installation and service must be performed by a qualified technician or service agency. Models: MiniMax Plus HP 400 (XLS400) MiniMax Plus HP 600 (XLS600) MiniMax Plus HP 800 (XLS800) MiniMax Plus HP 1000 (XLS1000) MiniMax Plus HP 230 (CP12) Part #471949 Revision #A © 2001 HydroTemp Manufacturing Co., Inc. Note: Specifications may change without notice. Owners Operational Information Only Technicians See Separate Installation Manual OWNERS SECTION - TABLE OF CONTENTS 1. OPERATIONAL INSTRUCTIONS ..............................................................................................3 - 7 a. Introduction & Design Features b. Heater Control Panels & L.E.D. Status Lights 2. START UP PROCEDURES ...........................................................................................................8 - 13 a. Compressor Warm Up Time b. Filter System Cleaning c. Operational Description c. Circulation Pump Timer d. Thermostat Setting e. Heat Loss & Pool Covers 3. OWNERS CARE .............................................................................................................................14 - 17 a. Placement Area b. Sprinkler Placement & Plants & Condensation Run Off c. Clearance and Air Flow. d. Cleaning The Unit e. Pool Circulation System Maintenance f. Auto Vacuum's & Vacuuming 4. PLUMBING & WATER FLOW ....................................................................................................18 - 19 a. Plumbing Connections & Auto Bypass b. Large Water Pump Plumbing Bypass c. Mandatory Chlorinator Loop & Check Valve 5. CHEMICAL & CHLORINATOR APPLICATION & USE ......................................................20 -24 a. Water Quality and Testing Values a. Heat Exchanger Protection & Sacrificial Water Fittings b. Chemical Feeder Placement & Use & Hand Feeding Chemicals c. Commercial Feeders d. Spa Chemical Application. 6. SHUT DOWN AND FREEZE PROTECTION PROCEDURES ................................................25 a. Seasonal Shut Down b. Short Term and Long Term Freezing Protection 7. OWNERS TROUBLE SHOOTING GUIDE................................................................................ 26 - 27 8. ELECTRICAL WIRING SPECIFICATIONS BY MODEL NUMBER .................................... 28 8. HOW TO GET SERVICE ............................................................................................................. 29 10. GLOSSARY OF TERMS ............................................................................................................. 30 - 33 ADDITIONAL MANUALS AVAILABLE: INSTALLATION MANUAL - TECHNICIAN ONLY OPTIONS/ACCESSORY MANUAL - TECHNICIANS ONLY OWNERS MANUALS Manufactured for Pentair Pool Products by HydroTemp Mfg. Co., Inc. THE MISUSE OF THIS PRODUCT CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. BE ADVISED OF THE FOLLOWING CONDI- TIONS THAT MAY EXIST: 1. ELECTROCUTION AND/OR FIRE DUE TO IMPROPER WIRING. 2. HAND AND HAIR ENTRAPMENT MAY OCCUR NEAR THE FAN LO- CATED ON THE TOP OF THIS UNIT. 3. LOSS OF POOL WATER AND/OR FLOODING AND/OR PROPERTY DAM- AGE. 4. DAMAGE AND/OR MISUSE TO THE PRODUCT RESULTING IN FAILURE OR EXCESSIVE WEAR. 5. ALL ELECTRICAL WORK BY LICENSED PROFESSIONAL ONLY. WARNING Owners/users should contact the factory service department for advice at: HYDROTEMP MANUFACTURING CO., INC. 12155 Metro Pkwy, Ste. 5 Ft Myers, FL 33912 (941) 768-1555 (941) 768-2856 (fax) HEAT PUMP EFFICIENCY Your new highly efficient heat pump pool/spa heater will deliver warm pool water for your comfort for pennies a day. For every dollar you spend to run your heat pump, you will receive between $4.00 and $5.00 worth of heat in return. The heat pump transfers the heat from the outside air to your pool or spa. Your heat pump costs about 60 to 75 percent less than L.P. Gas heaters to operate with less maintenance and gas storage tank is not needed. Your heat pump produces no pollution and no pilot lights to deal with. Approximate $2.34 Cost Per 100,000 Btu's of Heat Gas Pump $ 0.32 $1.65 LP Gas Natural $1.10 $ 0.96 Electric Oil Heat RETURN ON INVESTMENT The costs of installing a heat pump are somewhat higher than a gas heater but you will save enough in operational costs to offset the difference, probably in the first year or two. After a few heating seasons you will have saved enough, compared to LP gas heat, to pay for the entire heat pump and installation . LONGER SWIMMING SEASON A heat pump is the least expensive way to heat your pool. It will out perform solar by delivering heat on demand, no matter how much sunshine is available. A solar system with a gas back L.P. Gas back up will cost more to operate than the heat pump alone. In Florida, a heat pump offers a full 12 months of swimming season compared to a solar systems 10 month swimming season. A heat pump will provide higher temperatures than a solar system. Solar will not heat a spa on demand after sundown & during inclement weather. LOW MAINTENANCE Maintenance cost can be more for a gas h...

Ce manuel est également adapté pour les modèles :
matériel de pompage - XLS600 (422.14 kb)
matériel de pompage - XLS800 (422.14 kb)
matériel de pompage - MiniMax Plus CP12 (422.14 kb)
matériel de pompage - MiniMax Plus XLS1000 (422.14 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories