Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions Global Machinery Company, Modèle MOC6L

Fabricant : Global Machinery Company
Taille : 978.6 kb
Nom Fichier : a5d72182-bfb7-5c24-7534-a45489248b61.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


• Even when the tool is used as prescribed it is not possible to eliminate all residual risk factors. The following hazards may arise in connection with the tool’s construction and design: • Damage to the lungs if an effective breathing mask is not worn. • Damage to hearing if effective earmuffs are not worn. • Damage to the eyes if effective safety goggles or shield are not worn. WARNING. In the event that an air line is cut or broken, the air line needs to be immediately disconnected from the compressor at the quick release fitting. This will automatically stop the air from free flowing. A broken air line which is not supported is extremely dangerous and can whip around very quickly, both with the capability of striking people, and blowing foreign particles into the air. Do not attempt to catch the air line but immediately keep bystanders well clear. Disconnecting the remaining hose from the quick release fitting on the unit will automatically shut off the air supply. Turn off the compressor at the On / Off rocker switch. Unpacking Due to modern mass production techniques, it is unlikely that your GMC Power Tool is faulty or that a part is missing. If you find anything wrong, do not operate the tool until the parts have been replaced or the fault has been rectified. Failure to do so could result in serious personal injury. Components The MOC6L air compressor is supplied with the following components: a. Air compressor b. Blow gun c. Blow gun adaptor d. Tapered inflation fitting e. Tire chuck f. Inflation needle g. Nitto fitted air hose coil h. 1/4” male nitto plugs/adaptors (X2) i. Roll of teflon tape Know your product 1. On/off switch 2. Handle 3. On board removable storage container 4. Fold away handle 5. Cooling air outlets 6. Wheels (X2) 7. Levelling feet (X2) 8. Quick connect regulated outlet valve 9. Regulating knob 10. Safety valve 11. Tank pressure gauge 12. Regulated outlet pressure gauge 13. Drain cock 14. Power cord storage 15. Blow gun 16. Blow gun adaptor 17. Tapered inflation fitting 18. Tire chuck 19. Inflation needle 20. Nitto fitted air hose coil 21. 1/4” Nitto male plugs/adaptors (X2) 1 2 3 20 12 11 18 16 17 7 6 9 21 15 19 8 13 14 5 4 10 To start the air compressor 1. Check the rating label on the compressor indicates 230V-240V. 2. Make sure that the selected location for the compressor is clean, dry, well ventilated and without any obstruction. 3. Conduct a visual check to the make sure that compressor is not damaged and is fully in tack. 4. Make sure that he drain cock (13) is installed and screwed into the closed position. 5. Connect the air hose to the quick coupler located on the air compressor, by pushing back the outer sleeve of the quick coupler (Fig. A) and inserting the end of the hose. Release the outer sleeve and make sure the hose stays in place (Fig. B). 6. Install the desired air accessory into the quick coupler at the end of air hose by pulling back on the outer sleeve of the quick coupler and inserting the accessory into it. Release the outer sleeve and make sure the accessory and hose are securely connected. For instructions on how to assemble the accessories refer to pages 11 and 12. 7. Plug in the mains cable of the compressor to a standard 240V household power point and turn it on. 8. To start the compressor, press the yellow “On/Off” (1) switch to the “on” setting located on top of the compressor (Fig. C). WARNING. Be aware that pressurised air will be discharged from the outlet and care should be taken that this discharge is not directed towards you the operator, or other persons within the area. 9. To stop the compressor, push the yellow “On/Off” (1) switch to the “off” setting. Operating the air compressor 1. The pressure in the tank is controlled by the action of a pressure switch. When the set maximum pressure is reached the pressure switch activates and the motor is switched off. The pressure then decreases as the air is used by the connected tool until the set minimum pressure is reached after which the pressure switch causes the motor to switch on again. The operator of the compressor should be well aware that during use of the compressor the motor will start and stop under the influence of the rising or falling pressure in the tank. The motor will start without any warning. 2. The maximum and minimum pressures are factory set and the operator should not try to change them. 3. All accessories are connected to the regulated outlet valve (8). 4. The pressure of the regulated outlet, as shown on the regulated outlet pressure gauge (12), can be changed by turning the regulating knob (9) (Fig. D). Note. To obtain the correct output reading on the regulated output gauge, the air must be flowing through the regulated outlet valve and the selected air tool/accessory. The air pressure regulating knob should be adjusted and the gauge must be read. Only read the gauge when the regulated outlet valve has the air hose connected with the selected air tool/accessory attach...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories