|
Facilité d'utilisation
· Press Enter. 3-30 A-61074 April 1997 Detection range Detection range defines the amount of tolerable skew. The default for all modes is 10–30 degrees. The options are: — 5–30 degrees—results in an error being reported if the amount of document skew is between 5 and 30 degrees. — 10–30 degrees—results in an error being reported if the amount of document skew is between 10 and 30 degrees. · Select Detection Rangefrom the Skew Monitor menu. Mode Number: 01 Mode Name: MODE01 Item #: 8.2 Mode Configuration Single Index Format Patch Reader Off 6006 IA Field Width COIN2 Port Select n/a 3111 Level Rules OCR n/a Supprs IA Display Format Bar Code Reader Off FthenR Adjoining IA Printr Controller Supprs None Batching Front Printer Off Off Length Monitor Rear Printer Off Off Skew Monitor Mode Name MODE0 NA NA Footswitch Overrides No Sav Don't Save & End Session Save & End Session Don't Save & Prev Menu Save & Prev Menu Skew Monitor On/Off Detection Range Error Response Previous Menu Detection Range 5 – 30 Degrees 10 – 30 Degrees Previous Menu · Select the desired skew detection range. · Press Enter. A-61074 April 1997 Error response Error response defines the action taken when a document skew is detected. The default for all modes is Display and Beep. The options are: —Display Error Message—results in an error message appearing on the Operator Control Panel (E107–Doc Skew Monitor Warning). — Display and Beep—results in an error message appearing on the Operator Control Panel (E107–Doc Skew Monitor Warning), accompanied by an error tone. — Stop, Display, & Beep—results in the transport shutting down, and an error message appearing on the Operator Control Panel (E204–Re-Scan-Skew Moniotr Er), accompanied by an error tone. · Select Error Responsefrom the Skew Monitor menu. Mode Number: 01 Mode Name: MODE01 Item #: 8.3 Mode Configuration Single Index Format Patch Reader Off 6006 IA Field Width COIN2 Port Select n/a 3111 Level Rules OCR n/a Supprs IA Display Format Bar Code Reader Off FthenR Adjoining IA Printr Controller Supprs None Batching Front Printer Off Off Length Monitor Rear Printer Off Off Skew Monitor Mode Name MODE0 NA NA Footswitch Overrides No Sav Don't Save & End Session Save & End Session Don't Save & Prev Menu Save & Prev Menu Skew Monitor On/Off Detection Range Error Response Previous Menu Error Response Display Error Message Display and Beep Stop, Display, & Beep Previous Menu · Select the desired error response. · Press Enter. 3-32 A-61074 April 1997 Footswitch Footswitch defines the options required when using the footswitch accessory. · Select Footswitchfrom the Mode Configuration window. Mode Number: 01 Mode Name: MODE01 Item #: 9.0 Mode Configuration Single Index Format Patch Reader Off 6006 IA Field Width COIN2 Port Select n/a 3111 Level Rules OCR n/a Supprs IA Display Format Bar Code Reader Off FthenR Adjoining IA Printr Controller Supprs None Batching Front Printer Off Off Length Monitor Rear Printer Off Off Skew Monitor Mode Name MODE0 NA NA Footswitch Overrides No Sav Save & End Session Don't Save & End Session Save & Prev Menu Don't Save & Prev Menu Footswitch Press Definition Confirmation Tone Release Definition Previous Menu The following pages provide instructions on how to define the footswitch options. When the footswitch definitions are complete, you will automatically be returned to this window. To close the Footswitchmenu: · Select Previous Menu. Proceed to make any additional mode configuration definitions. A-61074 April 1997 Press definition Press definition defines the action which is taken when the footswitch is pressed. The default for all modes is No Action. The options are: —Level 0—document Level 0 will be assigned to the next document. — Level 1—document Level 1 will be assigned to the next document. — Level 2—document Level 2 will be assigned to the next document. — Level 3—document Level 3 will be assigned to the next document. — Increment—results in the next document being assigned the next document level, based upon the Level Rules established using the Level Rules option. — No Action—results in no action taking place when the footswitch is pressed. · Select Press Definitionfrom the Footswitch menu. Mode Number: 01 Mode Name: MODE01 Item #: 9.1 Single 6006 3111 Supprs FthenR None Off Off NA NA Index Format IA Field Width Level Rules IA Display Format Adjoining IA Batching Length Monitor Skew Monitor Footswitch Patch Reader COIN2 Port Select OCR Bar Code Reader Printr Controller Front Printer Rear Printer Mode Name Overrides Off n/a n/a Off Supprs Off Off MODE0 No Sav Save & End Session Save & Prev Menu Don't Save & End Session Don't Save & Prev Menu Mode Configuration Footswitch Press Definition Confirmation Tone Release Definition Previous Menu Press Definition Level 0 Level 1 Level 2 Level 3 Increment No Action Previous Menu · Select the desired action. · Press Enter. 3-34 A-61074 April 1997 Confirmation tone Confirmation tone enables or disables the Confirmation Tone wh...
Ce manuel est également adapté pour les modèles :matériel de pompage - 5500 (384.6 kb)
matériel de pompage - 5500 (384.6 kb)
matériel de pompage - 7500 (384.6 kb)