|
Facilité d'utilisation
Read and understand the Owner's Manual before operating the pump. Failure to do so could result in persona! injury or equipment damage. 1 CONTENTS 1. SAFETY INSTRUCTIONS................................................................................................................3 2. CAUTION LABEL LOCATION......................................................................................................4 3. COMPONENT IDENTIFICATION.............................................................5 4. PREPARATION............................................................................................................................................6 5. STARTING THE ENGINE..................................................................................................................10 6. OPERATION..................................................................................................................................................12 7. STOPPING THE ENGINE ..................................................................................................................13 8. MAINTENANCE ........................................................................................................................................14 9. TRANSPORTING/STORAGE........................................................................................................19 10. TROUBLESHOOTING..........................................................................................................................21 11. SPECIFICATIONS....................................................................................................................................23 12. WARRANTY SERVICE........................................................................................................................24 2 1. SAFETY INSTRUCTIONS ItwARNING To ensure safe operation • To prevent fire hazards and to provide adequate ventilation, keep the pump at least 3 ft away from buildings and other equipment during operation. • Do not place flammable objects such as gasoline, matches, etc.. close to the pump while it is running. • Refuel in a well ventilated area with the pump stopped. Gasoline is flammable and explosive under certain conditions. » Do not overfill the tank. There should be no fuel in the filler neck. Make sure that the filler cap is closed securely. if any fuel is spilled, clean it up completely before starting the engine. • Do not smoke or allow flames or sparks where the pump is refueled or where gasoline is stored. • Exhaust contains poisonous carbon monoxide gas. Avoid inhalation of exhaust gases. Never run the pump in a closed garage or confined area. • Operate the pump on a level surface, tf the engine is tilted, fuel spillage may result. • Nothing should be placed on the engine, it will cause fire hazards. » Know how to stop the pump quickly and understand operation of all the controls. Never permit anyone to operate the pump without proper instructions. • Keep children and pets away from the pump when it is in operation. • Keep away from rotating parts while the pump is running. 3 2. CAUTION LABEL LOCATION PUMP CAUTION LABEL CAUTION! DO NOT RUN WITHOUT PRIMINO WATER. DRY OPERATION WILL BURK THE SEAL PRECAUCIÓN! NO HABA FANCJOKAR SIN CEBADO FUNCIONAMIENTO SECO QUEMA EL SELLO. VDR5ICHTI VOR DEM ANLAUFEN BEI TESTUND LEERLAUF GEHÄUSE MIT WASSER REFQlLEN. TflOCKENAUF ZERSTÖRT DIE DICHTUNGEN. PRÉCAUTION! NE FAITE PAS 1 FONCTIONNER SANS AMOflSAGE. FONCTIONNEMENT AU SEC BRULE LE ! JOINT D'ETANCHEITE. 1........................................................V 4 3. COMPONENT IDENTIFICATION
matériel de pompage - WH15X (479.97 kb)