Fabricant : Goodman Mfg
Taille : 977.43 kb
Nom Fichier :
|
Facilité d'utilisation
They are not intended to describe complete systems, nor any particular system. It is the responsibility of the system designer, not Grant Engineering UK Ltd., to determine the necessary components for and configuration of the particular system being designed including any additional equipment and safety devices to ensure compliance with building and safety code requirements. 4.1 S-Plan Type - Monovalent 4.2 Extended S-Plan Type - Monovalent Heat Pump ATC Heat Pump ATC Flow Flexible pipe Auto Bypass Isolating valve Isolating valve Return CH FlowDHW Flow CH ReturnDHW Return CH ReturnDHW Return Cylinder Stat Room Stat Internal wiring centre Heating Load Heating Load Heating Load Programmer Grant Aerona Heat Pump Primary PumpCondenser CH FlowDHW Flow Cylinder Stat Room Stat Internal wiring centre Programmer Figure 4-1: Monovalent system - with S-Plan type controls Outside wall Outside wall Flow Flexible pipe Auto Bypass Isolating valve Isolating valve Return Grant Aerona Heat Pump Primary PumpCondenser The following system diagrams are only concept drawings and not detailed engineering drawings. They are not intended to describe complete systems, nor any particular system. It is the responsibility of the system designer, not Grant Engineering UK Ltd., to determine the necessary components for and configuration of the particular system being designed including any additional equipment and safety devices to ensure compliance with building and safety code requirements. 4 Hydraulic Diagrams IMPORTANT The following are examples of suitable systems Hydraulic Figure 4-2: Monovalent system - with extended S-Plan type controls 4 Hydraulic Diagrams 10 Hydraulic Diagrams 4.3 S-Plan Type - Bivalent CH Flow DHW Flow Heating Load DHW Return CH Return Room Stat Internal wiring centre Programmer Boiler 200mm minimum R F Cylinder Stat The following are examples of suitable systems Figure 4-4: Bivalent system - with boiler manifold and S-Plan type controls Outside wall Auto Bypass Boiler manifold Flow Flexible pipe Isolating valve Isolating valve Return Grant Aerona Heat Pump Primary PumpCondenser Heat Pump ATC IMPORTANT The following system diagrams are only concept drawings and not detailed engineering drawings. They are not intended to describe complete systems, nor any particular system. It is the responsibility of the system designer, not Grant Engineering UK Ltd., to determine the necessary components for and configuration of the particular system being designed including any additional equipment and safety devices to ensure compliance with building and...
Ce manuel est également adapté pour les modèles :matériel de pompage - HPAW110 (977.43 kb)
matériel de pompage - HPAW130 (977.43 kb)
matériel de pompage - HPAW130 (977.43 kb)
matériel de pompage - HPAW155 (977.43 kb)