Log:
Évaluations - 3, GPA: 4.3 ( )

Instructions York, Modèle SUNLINE 2000 B1CH240

Fabricant : York
Taille : 769.74 kb
Nom Fichier : 6e0890d9-e570-4f21-970c-9c1daccd1ea1.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


511.06-N3Y 4 POINT LOADS . 6 POINT LOADS FIG. 8- FOUR AND SIX POINT LOADS TABLE 5 - FOUR AND SIX POINT LOADS UNIT 4 - POINT LOADS (LBS) TOTAL A B C D 180 2,190 513 535 583 559 240 2,390 514 538 684 654 NOTE: These weights are with economizer and 36kW electric heat. UNIT 6 - POINT LOADS (LBS) TOTAL A B C D E F 180 2,190 342 358 373 388 372 357 240 2,390 343 359 407 456 436 389 NOTE: These weights are with economizer and 36kW electric heat. Unitary Products Group 511.06-N3Y TABLE 6 -SUPPLY AIR BLOWER PERFORMANCE (15 TON) 180 MBH - BOTTOM DUCT CONNECTIONS BLOWER SPEED, (RPM) MOTOR PULLEY (TURNS OPEN)* CFM 4500 5250 6000 6750 7200 ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 208 VOLT AND STANDARD DRIVE 850 870 915 965 980 1010 1040 6.0** 5.5 4.5 3.5 3.0 2.0 1.0 0.9 1.0 1.1 1.2 1.3 1.4 1.5 2.4 2.5 2.6 2.9 3.0 3.1 3.2 2.2 2.3 2.4 2.6 2.7 2.8 2.9 0.7 0.8 0.9 1.0 1.1 1.2 1.3 3.0 3.1 3.4 3.6 3.7 3.8 3.9 2.7 2.8 3.0 3.2 3.3 3.4 3.5 0.5 0.6 0.7 0.8 0.9 1.0 1.1 3.2 3.5 3.7 4.0 4.1 4.2 4.5 2.9 3.1 3.3 3.6 3.7 3.8 4.0 - 0.2 0.3 0.5 0.6 0.7 0.9 - 4.1 4.4 4.7 4.8 5.0 5.2 - 3.7 3.9 4.2 4.3 4.5 4.7 - - 0.2 0.4 0.5 0.6 0.7 - - 4.5 4.9 5.1 5.4 5.7 - - 4.0 4.4 4.6 4.8 5.1 208 VOLT AND HIGH SPEED DRIVE ACCESSORY 965 980 1025 1065 1095 1130 1170 6.0 5.5 4.5 3.5 3.0 2.0 1.0 1.2 1.3 1.5 1.6 1.7 1.9 2.1 2.9 3.0 3.2 3.4 3.5 3.7 3.9 2.6 2.7 2.9 3.0 3.1 3.3 3.5 1.0 1.1 1.3 1.4 1.5 1.7 2.0 3.6 3.7 3.9 4.0 4.2 4.5 4.7 3.2 3.3 3.5 3.6 3.8 4.0 4.2 0.8 0.9 1.1 1.2 1.3 1.5 1.8 4.0 4.1 4.5 4.7 4.9 5.1 5.5 3.6 3.7 4.0 4.2 4.4 4.6 4.9 0.5 0.6 0.8 1.0 1.2 - - 4.7 4.8 5.1 5.5 5.7 - - 4.2 4.3 4.6 4.9 5.1 - - 0.4 0.5 0.7 - - - - 5.0 5.1 5.6 - - - - 4.4 4.6 5.0 - - - - 230/460/575 VOLT AND STANDARD DRIVE 870 915 965 980 1040 1065 6.0** 5.0 4.0 3.5 2.0 1.0 1.0 1.1 1.2 1.3 1.5 1.6 2.4 2.6 2.9 3.0 3.2 3.3 2.2 2.4 2.6 2.7 2.9 3.0 0.8 0.9 1.0 1.1 1.3 1.4 3.1 3.3 3.6 3.7 3.9 4.0 2.8 3.0 3.2 3.3 3.5 3.6 0.6 0.7 0.8 0.9 1.1 1.2 3.5 3.7 4.0 4.1 4.5 4.7 3.1 3.3 3.6 3.7 4.0 4.2 0.2 0.3 0.5 0.6 0.9 1.0 4.1 4.4 4.7 4.8 5.3 5.5 3.7 3.9 4.2 4.3 4.7 4.9 - 0.2 0.4 0.5 0.7 - - 4.5 5.0 5.1 5.7 - - 4.0 4.4 4.6 5.1 - 230/460/575 VOLT AND HIGH SPEED DRIVE ACCESSORY 980 1040 1065 1095 1130 1170 1190 6.0 4.5 4.0 3.5 2.5 1.5 1.0 1.3 1.5 1.6 1.7 1.9 2.1 2.2 2.9 3.2 3.4 3.5 3.7 3.9 4.0 2.6 2.9 3.0 3.1 3.3 3.5 3.6 1.1 1.3 1.4 1.5 1.7 2.0 2.1 3.7 3.9 4.0 4.2 4.5 4.7 4.8 3.3 3.5 3.6 3.8 4.0 4.2 4.3 0.9 1.1 1.2 1.3 1.5 1.8 2.0 4.1 4.5 4.7 4.9 5.1 5.5 5.7 3.7 4.0 4.2 4.4 4.6 4.9 5.1 0.6 0.9 1.0 1.2 - - - 4.8 5.3 5.5 5.7 - - - 4.3 4.7 4.9 5.1 - - - 0.5 0.7 - - - - - 5.1 5.7 - - - - - 4.6 5.1 - - - - - NOTES: 1. Blower performance includes fixed outdoor air, 2" T/A filters, a dry indoor coil and no electric heat. 2. Refer to Page 12 for additional static resistances. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. * Do NOT close the pulley below 1 turn open. ** Factory setting. Unitary Products Group 511.06-N3Y TABLE 7 - SUPPLY AIR BLOWER PERFORMANCE (20 TON) 240 MBH - BOTTOM DUCT CONNECTIONS BLOWER SPEED, (RPM) MOTOR PULLEY (TURNS OPEN)* CFM 6000 7000 8000 9000 9400 ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 208 VOLT AND STANDARD DRIVE 870 900 930 950 980 1015 6.0** 5.0 4.0 3.0 2.0 1.0 0.4 0.8 1.1 1.3 1.6 1.9 2.1 3.2 4.1 4.6 5.3 5.9 1.8 2.7 3.4 3.9 4.5 5.0 0.1 0.5 0.9 1.1 1.4 1.7 2.3 3.5 4.5 5.1 5.8 6.5 2.0 2.9 3.8 4.3 4.9 5.5 - 0.2 0.6 0.8 1.2 1.5 - 3.8 4.9 5.5 6.3 7.0 - 3.2 4.1 4.6 5.3 5.9 - - 0.1 0.4 0.7 1.0 - - 5.1 5.9 6.9 7.7 - - 4.3 5.0 5.8 6.5 - - - - 0.2 0.6 - - - - 7.3 8.2 - - - - 6.1 6.9 208 VOLT AND HIGH SPEED DRIVE ACCESSORY 950 980 1010 1020 1035 1050 1075 1100 6.0 5.0 4.0 3.5 3.0 2.5 2.0 1.0 1.3 1.6 1.8 1.9 2.0 2.1 2.3 2.4 4.6 5.3 5.8 6.1 6.2 6.4 6.6 6.7 3.9 4.5 4.9 5.1 5.2 5.4 5.5 5.6 1.1 1.4 1.7 1.8 1.9 2.0 2.1 2.2 5.1 5.8 6.3 6.5 6.8 7.0 7.2 7.3 4.3 4.9 5.3 5.5 5.7 5.9 6.0 6.1 0.8 1.2 1.5 1.6 1.7 1.8 1.9 2.1 5.5 6.3 6.9 7.1 7.4 7.6 7.8 7.9 4.6 5.3 5.8 6.0 6.2 6.4 6.6 6.7 0.4 0.7 1.0 1.1 1.2 1.3 1.5 - 5.9 6.9 7.5 7.8 8.1 8.3 8.6 - 5.0 5.8 6.3 6.6 6.8 7.0 7.2 - - 0.2 0.5 0.6 0.7 - - - - 7.3 7.9 8.3 8.6 - - - - 6.1 6.7 7.0 7.3 - - - 230/460/575 VOLT AND STANDARD DRIVE 870 900 930 950 980 1015 1025 6.0** 5.0 4.0 3.5 2.5 1.5 1.0 0.4 0.8 1.1 1.3 1.6 1.9 2.0 2.1 3.2 4.1 4.6 5.3 5.9 6.1 1.8 2.7 3.4 3.9 4.5 5.0 5.1 0.1 0.5 0.9 1.1 1.4 1.7 1.8 2.3 3.5 4.5 5.1 5.8 6.5 6.6 2.0 2.9 3.8 4.3 4.9 5.5 5.6 - 0.2 0.6 0.8 1.2 1.5 1.6 - 3.8 4.9 5.5 6.3 7.0 7.3 - 3.2 4.1 4.6 5.3 5.9 6.1 - - 0.1 0.4 0.7 1.0 1.1 - - 5.1 5.9 6.9 7.7 7.9 - - 4.3 5.0 5.8 6.5 6.7 - - - - 0.2 0.6 0.7 - - - - 7.3 8.2 8.6 - - - - 6.1 6.9 7.3 230/460/575 VOLT AND HIGH SPEED DRIVE ACCESSORY 950 980 1015 1035 1050 1080 1100 1120 6.0 5.0 4.0 3.5 3.0 2.0 1.5 1.0 1.3 1.6 1.9 2.0 2.1 2.3 2.4 2.5 4.6 5.3 5.9 6.2 6.4 6.6 6.7 6.8 3.9 4.5 5.0 5.2 5.4 5.5 5.6 5.7 1.1 1.4 1.7 1.9 2.0 2.1 2.2 2.3 5.1 5.8 6.5 6.8 7.0 7.2 7.3 7.4 4.3 4.9 5.5 5.7 5.9 6.0 6.1 6.2 0.8 1.2 1.5 1...

Ce manuel est également adapté pour les modèles :
matériel de pompage - SUNLINE 2000 B1CH180 (769.74 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories