When the circulation pump timer stops the water flow, the water pressure switch will shut the unit down. When the pump restarts for the next day, the pressure switch will close and allow the heater to run. Water Pressure Switch Location Filter & Trap Locations Warm Air In Cool Air Out CompressorAir Coil Heat Exchanger Plumbing Bypass Manifold Refrigerant Lines Hot Gas transfer the heat from the outside air to the pool water. Orifice Assembly Filter Dryer Warm Air In Cool Air Out CompressorAir Coil Heat Exchanger Plumbing Bypass Manifold Refrigerant Lines Hot Gas transfer the heat from the outside air to the pool water. Orifice Assembly Filter Dryer E WATER FLOW & EXISTING WATER PUMP To filter the pool water each day, the water pump will come on & off according to the existing timer device. The heater will only heat if there is water running through it and it operates long enough. pool or spa WATER PRESSURE SWITCH When water starts flowing through the unit the water pressure switch will activate and allow the unit to run. When the circulation pump timer stops the water flow, the water pressure switch will shut the unit Water Pressure Switch off. When the pump restarts for the next day, the pressure switch will Location activate and allow the heater to run again. THERMOSTAT CONTROL & SETTINGS Turning up the thermostat will start the unit. When the pool water has been heated to the thermostat setting, the unit will shut off. When the pool water temperature loses one to two degrees, the thermostat will activate the unit. There are no temperature graduate numbers printed on the thermostat face. To obtain an exact temperature for a pool, turn the t-stat 3/4's of the way up and then place a pool type thermometer in the pool water itself. Once the water has reached your target temperature on the thermometer, turn the thermostat knob backwards until the heater just shuts off. There fore your thermostat will be set at the thermom eter reading. THERMOSTAT CONTROL & SETTINGS FOR HEAT & COOL MODELS For heating mode on these models, make sure toggle is selected to heat and follow the previous instructions above. For cooling mode, make sure toggle is selected to cool. Turning down the thermostat counter clockwise will start the unit running. When the pool water has been cooled to the thermostat setting, the unit will shut off. When the pool water temperature rises one to two degrees, the thermostat will activate the unit. There are no temperature graduate numbers printed on the thermostat face. To obtain an exact temperature, turn the t-stat all the way down and then place a pool type thermometer in the pool water itself. Once the water has reached your target temperature on the thermometer, turn the thermostat knob forwards until the heater just shuts off. Therefore your thermostat will be set at the thermometer reading. FAN-AIR CIRCULATION Once the t-stat is activated the fan will begin to turn. To collect the heat from the air, the fan circulates warmer air through the evaporator air coil at about 4200 cubic feet per minute. The fan runs independently from the compressor. The compressor will start within 5 to 7 minutes after the fan. EVAPORATOR AIR COIL The fan circulates the warmer outside air through the evaporator air coil to collect any available heat. The cooler refrigerant absorbs this heat. This evaporates the refrigerant into a gas. Therefore the compressor can compress the gas to maximize the gained heat from the air. ............................................................ THERMOSTAT SPRE ADY A MO DE MO D E P OO L C O NT RO L WAT ER S W T-ST AT LOW PRE SS. HIG H PRES O K . OK OK O K COMPRESSOR Once the fan is running, the compressor will start 5 to 7 minutes later and is controlled by a time delay device. The compressor pumps and compresses refrigerant gas. When gas is compressed it gets very hot and intensifies the energy and then is released to the pool water. This compressed hot gas is pumped through the heat exchanger where it delivers heat to the pool water passing through the same heat exchanger. WATER HEAT EXCHANGER The compressed hot gas releases its heat to the pool water inside the heat exchanger. The ex changer is a tube within a tube construction, wa ter passing through the inner tube, and the hot refrigerant passing through the outer tube. The refrigerant is transformed into a liquid (condensed) state as it releases it's heat to the pool water. Therefore, it is also referred to as a condenser coil. The alloy exchanger is designed for maximum transfer surface area and strength. Cross section SYSTEM OVERVIEW Foam Insulated The heat pump system Warm Water Cool Water uses 410-A refrigerant to In Out HP Switch LP Switch 9 TIME CLOCK SETTING TIME CLOCK SETTING INITIAL HEAT UP TIME (HEATERS) You should start by letting the circulation pump run 24 hours a day until the pool reaches the desired temperature. Once the pool is up to your desired temperature you should reset the timer for a cycle of 6 to ...

Ce manuel est également adapté pour les modèles :
matériel de pompage - HP 1000 (308.19 kb)
matériel de pompage - HP 400 (308.19 kb)
matériel de pompage - HP 600 (308.19 kb)
matériel de pompage - HP 800 (308.19 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories