Log:
Évaluations - , GPA: ( )

Instructions Dimplex, Modèle SI 14CS

Fabricant : Dimplex
Taille : 1.19 mb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


proportional pump energy) Power consumption (incl. proportional pump power input) Brine inlet temperature in [°C] 17 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.4 Pressure Losses .. 7CS 0 5000 10000 15000 20000 25000 30000 35000 40000 0 0,5 1 1,5 2 2,5 3 3,5 4 0 5000 10000 15000 20000 25000 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 Pressure losses of evaporator at –5°C brine temperature without brine accessories Pressure loss 10 kPa at a rated brine flow rate of 1.7 m3/h Pressure loss in [Pa] Brine flow rate in [m3/h] Pressure loss in [Pa] Pressure losses of condenser at 35°C heating water outlet temperature Pressure loss 2.5 kPa at a rated heating water flow rate of 0.6 m3/h Heating water flow rate in [m3/h] 18 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.5 Performance Curves .. 9CS 0 2 4 6 8 10 12 14 16 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Heating capacity in [kW] Water outlet temperature in [ Conditions: Heating water flow rate 0,75 m3/h Brine flow rate 2,3 m3/h COP in the heating mode (incl. proportional pump energy) Power consumption (incl. proportional pump power input) Brine inlet temperature in [°C] 35 50 26 35 50 35 50 °C] 19 APPENDIX: 12.3 PERFORMANCE CURVES/DPRESSURE LOSSES 12.3.6 Pressure Losses .. 9CS 0 5000 10000 15000 20000 25000 30000 35000 40000 0 0,5 1 1,5 2 2,5 3 0 5000 10000 15000 20000 25000 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 Pressure loss in [Pa] Pressure losses of evaporator at –5°C brine temperature without brine accessories Pressure loss 16 kPa at a rated brine flow rate of 2.3 m3/h Pressure loss in [Pa] Brine flow rate in [m3/h] Pressure losses of condenser at 35°C heating water outlet temperature Pressure loss 4.5 kPa at a rated heating water flow rate of 0.75 m3/h Heating water flow rate in [m3/h] 20 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.7 Performance Curves .. 11CS 0,0 2,0 4,0 6,0 8,0 10,0 12,0 14,0 16,0 18,0 20,0 22,0 24,0 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Heating capacity in [kW] Water outlet temperature inConditions: Heating water flow rate 1,0 m3/h Brine flow rate 3,0 m3/h COP in the heating mode (incl. proportional pump energy) Power consumption (incl. proportional pump power input) Brine inlet temperature in [°C] 35 50 26 35 50 35 50 [°C] 21 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.8 Pressure Losses .. 11CS 0 5000 10000 15000 20000 25000 30000 35000 40000 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 0 2000 4000 6000 8000 10000 12000 14000 16000 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 Pressure loss in [Pa] Pressure losses of evaporator at –5°C brine temperature without brine accessories Pressure loss 13 kPa at a rated brine flow rate of 3.0 m3/h Pressure loss in [Pa] Brine flow rate in [m3/h] Pressure losses of condenser at 35°C heating water outlet temperature Pressure loss 3.5 kPa at a rated heating water flow rate of 1.0 m3/h Heating water flow rate in [m3/h] 22 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.9 Performance Curves .. 14CS 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Brine inlet temperature in [°C] Power consumption (incl. proportional pump power input) COP in the heating mode (incl. proportional pump energy) Conditions: Heating water flow rate 1,3 m3/h Brine flow rate 3,5 m3/h Heating capacity in [kW] Water outlet temperature in [° 35 50 26 35 50 35 50 C] 23 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.10 Pressure Losses .. 14CS 0 5000 10000 15000 20000 25000 30000 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 0 2000 4000 6000 8000 10000 12000 14000 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 Pressure loss in [Pa] Pressure losses of evaporator at –5°C brine temperature without brine accessories Pressure loss 13 kPa at a rated brine flow rate of 3.5 m3/h Pressure loss in [Pa] Brine flow rate in [m3/h] Pressure losses of condenser at 35°C heating water outlet temperature Pressure loss 3.5 kPa at a rated heating water flow rate of 1.3 m3/h Heating water flow rate in [m3/h] 24 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.11 Performance Curves .. 17CS 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Heating capacity in [kW] Water outlet temperature in [° Conditions: Heating water flow rate 1,5 m3/h Brine flow rate 3,8 m3/h COP in the heating mode (incl. proportional pump energy) Power consumption (incl. proportional pump power input) Brine inlet temperature in [°C] 35 50 26 35 50 35 50 C] 25 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.12 Pressure Losses .. 17CS 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000 24000 0 1 2 3 4 5 6 0 2000 4000 6000 8000 10000 12000 14000 0 0,2 0,4 0,6 0,8 1 1,2 1,4 1,6 1,8 2 2,2 2,4 2,6 Pressure loss in [Pa] Pressure losses of evaporator at –5°C brine temperature without brine accessories Pressure loss 9 kPa at a rated brine flow...

Ce manuel est également adapté pour les modèles :
matériel de pompage - SI 11CS (1.19 mb)
matériel de pompage - SI 17CS (1.19 mb)
matériel de pompage - SI 21CS (1.19 mb)
matériel de pompage - SI 5CS (1.19 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories