(A) Fuse size, Max. (A) 230 - 208/1/6 15 15 COMPRESSOR No. used R.L. Amps - L.R. Amps (A) Crankcase Heater Rotary-Hermetic 1 4.0-30 20W OUTDOOR FAN - TYPE Propeller Dia. (in.) - No. used 15-3/4 - 1 Type Drive - No. speeds Direct - 1 No. Poles - RPM 6 - 820 No. Motors - HP 1 - 1/38 CFM (High) 750 F.L. Amps. (A) 0.4 OUTDOOR COIL - TYPE Fin Type - Pipe Type Rows - F.P.I. Face Area (sq.ft.) Tube Size (in.) Aluminum Fin & Copper Pipe Slit Plate - Inner Riffled 2 - 15.9 3.29 3/8 INDOOR FAN - TYPE Dia. & Length (in.) - No. No. speeds No. Poles -RPM (High) No. Motors - HP CFM (HI/MED/LOW) F.L. Amps (A) Cross - Flow used 3-17/32 & 24-5/8 - 1 3 & Auto 4-1,450 1 - 1/75 220/190/160 0.2 INDOOR COIL - TYPE Fin Type - Pipe type Rows - F.P.I. Face Area (sq. ft.) Tube Size (in.) Drain Connection Size (in.) Aluminum Fin & Copper Pipe Slit Plate - Inner Riffled 2 - 14.1 1.63 3/8 23/32 REFRIGERANT Lbs. - R22 (O.D. Unit) Control Connection Line Length, Max (ft.) Lift difference, Max (ft.) Line Size - in. O.D. Discharge Line Size - in. O.D. Suction R22 2.91 Capillary Tube Flare 50 23 1/4 3/8 DIMENSIONS (in.) H x W x D Indoor Unit - Uncrated 13-19/32 x 31- 1/ 2 x 7- 3/32 -Crated 17- 3/16 x 33- 7/ 8 x9 -21/32 Outdoor unit -Uncrated 20- 7/8 x 29-17/32 x 11-1/32 -Crated 23- 17/32x 35-13/32 x13- 7/8 WEIGHT Net (lbs.) Shipping(lbs.) INDOOR 24.3 28.7 OUTDOOR 90.4 97.0 PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V) COOLING Total Capacity (BTU/H) Sensible Capacity (BTU/H) Latent Capacity (BTU/H) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) HEATING Total Capacity (BTU/H) HSPF Amps (A) Power Inputs (W) Back-up Strip Heater (KW) Outdoor Sound Rating(bels) FEATURE 9,000/8,800 5,690/5,530 3,310/3,270 10.0/10.0 2.2/2.1 4.5/4.6 950/930 10,900/10,700 6.8/6.8 4.7/4.8 1,030/980 1.0/0.82 7.0 Controls Remote Controller Temperature Control Microprocessor LCD Wireless type IC Thermostat Timer ON/OFF, 24 hours Night Setback Built-In Air Louver (Horizontal) Manual (Vertical) Manual Power Failure Automatic Restart Built-In Self Diagnosis Built-In Heating/Cooling Automatic Changeover Built-In OPTION Refrigerant Line Set AP0905BH (15 ft) AP0907BH (20 ft) AP0910BH (30 ft) Low Ambient Control N/A Fresh Air Intake N/A Central Remote ON-OFF Control Available Airduct Extension N/A Indoor Frame Extension N/A Condensate Drain Pump Available Non-Removable Remo-con Bracket Available OPERATING RANGE Cooling Maximum Minimum Heating Maximum Minimum CERTIFICATION Indoor Air Intake Temp. 95 F DB/71 F WB 67 F DB/57 F WB 80 F DB/67 F WB - F DB/ - F WB Outdoor Air Intake Temp. 115 F DB 67 F DB 75 F WB/65 F WB 17 F WB/15 F WB Shipping Volume (cu.ft.) 3.2 6.7 09KHS22 DIMENSIONAL DATA Indoor Unit: KHS0921, KHS0922 Wireless remote control unit CO I CD 2-13/64 19/32 7-11/64 Rear panel (center point of gravity) 31-1/2 7-3/32 OJ £2 Ci - 3 r 1-3/8 ■'tf CO o5 ■'it 2 3/ LO Outdoor Unit: CH0921, CH0922 Check port 1/4" narrow tubing service valve 3/8" wide tubing service valve Air intake 4 15/32 dia. hole Air intake Lv' 23-15/16 m rai— 10-23/32 8/ Air discharge _3j 2-3/8 WARRANTY SANYO products are warranted against defects in materials and workmanship for the period below; LABOR PARTS Compressor 30 Days 5 Years Other Components N/A 1 Year Full specific warranty rights, conditions, exclusions and obligations are specified in the warranty packed with each products. Because of a policy of continuous product improvements, SANYO reserves the right to change specifications and design without notice. SANYO FISHER COMPANY A Division of SANYO North America Corporation 21605 Plummer St. Chatsworth, CA 91311 Phone : (818) 998- 7322 Fax : (818)701-4160 Website: http://www.sanyohvac.com...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories