Log:
Évaluations - 3, GPA: 4.7 ( )

Instructions Porter-Cable, Modèle C2004

Fabricant : Porter-Cable
Taille : 2.91 mb
Nom Fichier : 46085dbd-d90a-4563-934c-8ac6c5c6acf2.pdf
Langue d'enseignement: enesfr
Aller à la télécharger



Facilité d'utilisation


5 - ENG •Attemptingtooperatecompressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury. •Anyrepairsrequiredonthisproductshould be performed by authorized service center personnel. HAZARD RISk OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT •Unsafeoperationofyourcompressor could lead to serious injury or death to you or others. • Reviewandunderstandallinstructions and warnings in this manual. • Becomefamiliarwiththeoperationand controls of the air compressor. •Keepoperatingareaclearofallpersons, pets, and obstacles. • Keepchildrenawayfromtheair compressor at all times. •Donotoperatetheproductwhenfatigued or under the influence of alcohol or drugs. Stay alert at all times. • Neverdefeatthesafetyfeatures of this product. •Equipareaofoperationwitha fire extinguisher. • Donotoperatemachinewithmissing, broken, or unauthorized parts. • Neverstandonthecompressor. HAZARD RISk OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT • Aportablecompressorcanfall from a table, workbench, or roof causing damage to the compressor and could result in serious injury or death to the operator. •Alwaysoperatecompressorinastablesecure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations. •Attemptingtooperatecompressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury. •Anyrepairsrequiredonthisproductshould be performed by authorized service center personnel. HAZARD RISk OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT •Unsafeoperationofyourcompressor could lead to serious injury or death to you or others. • Reviewandunderstandallinstructions and warnings in this manual. • Becomefamiliarwiththeoperationand controls of the air compressor. •Keepoperatingareaclearofallpersons, pets, and obstacles. • Keepchildrenawayfromtheair compressor at all times. •Donotoperatetheproductwhenfatigued or under the influence of alcohol or drugs. Stay alert at all times. • Neverdefeatthesafetyfeatures of this product. •Equipareaofoperationwitha fire extinguisher. • Donotoperatemachinewithmissing, broken, or unauthorized parts. • Neverstandonthecompressor. HAZARD RISk OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT • Aportablecompressorcanfall from a table, workbench, or roof causing damage to the compressor and could result in serious injury or death to the operator. •Alwaysoperatecompressorinastablesecure position to prevent accidental movement of the unit. Never operate compressor on a roof or other elevated position. Use additional air hose to reach high locations. 6 - ENG HAZARD HAZARD RISk FROM NOISE WHAT CAN HAPPEN HOW TO PREVENT IT •Undersomeconditionsand duration of use, noise from this product may contribute to hearing loss. •Alwayswearproperhearingprotection during use. SAVE THESE INSTRUCTIONS FOR FUTURE USE SPECIFICATIONS Model No. C2004 Bore 1.875" (47.6 mm) Stroke 1.250" (31.8 mm) Voltage/Hz-Single Phase 120/60 Minimum Branch Circuit Requirement 15 amps Branch Circuit Fuse Type Time Delay Air Tank Capacity 4 Gallons (15.1 liters) Approximate Cut-in Pressure 135 psig Approximate Cut-out Pressure 165 psig SCFM @ 90 psig 2.6 * Regulated Pressure Rating (Approximate) 3–150 psi Quick Connect Type 1/4" (6.4 mm) Industrial Noise Level 75.5 dBA + * Tested per ISO 1217 +Tested per ISO 3744:1995 Refer to Glossary for abbreviations. DECLARED NOISE EMISSION VALUES PER ISO 3744 Noise Emission Values Sound Pressure Level: LpA = 75.5 dBA re 20.PA Uncertainty in the Sound Pressure Level: KpA = 3.0 dBA re 20.PA Sound Power Level: LwA = 88.0 dBA re 1 pw Uncertainty in the Sound Power Level: KwA = 3.0 dBA re 1 pw The sum of the emission value and the uncertainty is the limit below which there is a 95% confidence the value of a single tool will lie below when the tool is new. 7 - ENG GLOSSARY GLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL®, CUL, CULUS, ETL®, CETL, CETLUS, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Standards for Safety. Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain lower level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off, protectin...

Ce manuel est également adapté pour les modèles :
matériel de pompage - N034163 (2.91 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories