Log:
Évaluations - 1, GPA: 3 ( )

Instructions EMI, Modèle S1H2A

Fabricant : EMI
Taille : 514.75 kb
Nom Fichier : 1483.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


A [05/08] JOB NAME: _____________________________________ LOCATION: _______________________________________ PURCHASER: _____________________________________________________________________________________ ENGINEER:_______________________________________________________________________________________ SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: _________________________________ DATE:____________________________________________ UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________ RiNG Submittal WLH S1H CapaCities: Cooling....................11,400 Btuh Heating (High)........ 10,600 Btuh Heating (Low)........... 6,200 Btuh Outdoor Design temp °F DB/WB Cooling.................................95/75 Heating (High)......................47/43 Heating (Low).......................17/15 indoor Design temp °F DB/WB Cooling.............................. 80/67 Heating.............................. 70/57 stanDarD Features: evaporator – High Wall mounted: • Universal unit mounted, infrared compatible control package, configurable to either unit mount or optional wall thermostat operation. • Compatible with most standard wall mounted, 24V thermostats • Motorized supply louver stanDarD Features: Condenser – Side Discharge / vertically arranged: • R-22 refrigerant • Factory installed LowAmbient cooling to 32°F • Duratec compressor protection package -SuctionAccumulator -Filter dryer -High pressure switch (manual reset) -Thermostatically controlled crankcase heater -Start assist • Coated wire coils and fan guards • Five year compressor / one year parts warranty emi eNGiNee • Integral field condensate pump connector • Condensate pan over flow protection • Anti-short cycle compressor protection • Indoor coil freeze protection • Dry mode for humidity control (optional electric heat required) • Memory back up for auto re-start following power outage • Fan purge WLH12 ELECTRICAL SPECIFICATIONS Volts/HZ/PHFan RLAHeaterK.W.AmpsTotal AmpsMin. VoltM.C.A.HACRBRKR 115/60/1 0.64 – – 0.64 104 0.8 15 115/60/1 0.64 .75 6.5 7.14 104 8.9 15 208/230/60/1 0.34 – – 0.34 197 0.4 15 208/230/60/1 0.34 3 13.04 13.38 197 16.7 20 HEAT PUMPS SYSTEM OPTIONS WITH WLH12/S1H2 Cooling Btuh Heating Btuh SEER HSPF SHR EER COP 11,400 10,600 13.0 8.0 .73 11.5 3.4 S1H ELECTRICAL SPECIFICATIONS Model Volts/HZ/PH Total Amps Min Volt M.C.A. HACR BRKR S1H2A 115/60/1 10 104 12.2 20 S1H2D 208/230/60/1 5.1 197 6.2 15 Thermostatically controlled crankcase heater – This feature energizes the crankcase heater only when needed, removes the heater from the electrical circuit at conditions where it’s not required, saving unnecessary Watts, and increasing overall system efficiency. Rome, New York, USA Enviromaster International LLC 1 WLH dIMENSIONS ANd SPECIFICATIONS EMI ENgINEERINg SUBMITTAL WLH12-S1H2000_101 EMI ENgINEERINg SUBMITTAL WLH12-S1H2000_101 NOTE: Due to ongoing development programs, design and specifications may change without notice. 9.” 15 .” 38 .” 24” 26 .” 5 .” 1 .” 2” 4.” Tubing Access Mounting Bracket WLCA INTERCONNECTINg LINE SIZES Capacity Btuh Liquid O.d. Suction O.d. Condensate drain Conn. I.d. 12 1/4” 1/2” 1/2” dISCHARgE AIR SPEEd ANd FLOW @ 230V Model High CFM Low CFM Coil FPM Throw/ Ft. 9/12 400 350 Dry 900 15 SOUNd VALUES (230V High Speed Fan) SHIPPINg WEIgHT dBA Lbs. 45 60.25 S1H SPECIFICATIONS ANd dIMENSIONS emi@enviromaster.com 2 24" 15" 36" ElectricalConnections1/2”DiameterLagHoles4.”4.”14 11/16” INTERCONNECTINg TUBINg SPECIFICATIONS S1 Model Max. Length Max. Lift Liquid Line O.d. Suction Line O.d. Ref. S1H2 100’ 35’ 1/4" 1/2" R-2212 7/16” 3” Sound data Shipping Weight Size Btuh dBA Lbs. 12 59 98 EMI ENgINEERINg SUBMITTAL WLH12-S1H2000_101 EMI ENgINEERINg SUBMITTAL WLH12-S1H2000_101 part One “GeneraL” The heat pump air conditioning systems shall be an EMI America Series split system. The system shall consist of a high wall mounted packaged evaporator section Model WLH12 and matc...

Ce manuel est également adapté pour les modèles :
matériel de pompage - WLH12-S1H2000_101 (514.75 kb)
matériel de pompage - S1H2D (514.75 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories