Log:
Évaluations - 0, GPA: 5 ( )

Instructions EMI, Modèle S2H

Fabricant : EMI
Taille : 1.89 mb
Nom Fichier : 414e5419-532d-484c-84c3-4eda08426ad2.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


A [06/08] SpecificationS and performance Heat pump Nominal Capacities: 9,000 and 12,000 Btuh dEsCrIPtIon EMI offers the finest high capacity dual zone outdoor units in the ductless split market, the S2H High Capacity Condensing Unit. The S2H allows the installation of two circuits from a single outside location when space or aesthetic requirements limit the use of locations. The S2H has easy access interconnect valves on the back of the unit and each zone is independent so no mixing of refrigerant will occur. All 9,000 and 12,000 Btuh units are equipped with the Duratec Performance package which includes a large capacity suction accumulator with surge baffles and enhanced oil management and a factory installed solid core filter drier. All EMI products are subject to ongoing develop ment programs so design and specifications may change without notice. Cabinet • Vertically arranged side discharge CondEnsEr standard FEaturEs • Scratch and dent resistant injection molded front access panel • Powder coated (2,000 hour salt spray tested) 18 and 20 gauge aluminized steel • Concealed service valves • Easy access hose connections at 45° from valve body rotary compressors. Motors are PSC type with inherent overload protection. Condenser Fan/Motor - The condenser fan is a large diameter, high efficiency propeller type, which is directly connected to the totally enclosed PSC motor. The S2H units are draw-through airflow design and the PSC motor is fitted with internal overload protection. Condenser Coil -Condenser coils are seamless copper tubing arranged in staggered configuration with enhanced aluminum fins tested to 460psig. The tubes are mechanically expanded for secure bonding to the fin shoulder. Refrigeration Circuits -The S2H is delivered with pre-charged refrigerant for the condenser coils and evaporators while charging of field installed piping is required. Unit refrigeration service valves are solid brass for sweat connection. Solid core filter driers are factory installed on all models. Refrigerant Run Options - The standard system will support refrigerant runs to the inside unit of 35’ of lift, up to 100’ of interconnect. Reverse Cycle Operation S2H - A four-way reversing valve, solenoid activated by 24v, is energized for cooling operation. A TXV with internal check valve provides proven operation through all temperature ranges when in the heat pump mode. Controls and Components: • Compressor and fan motor contactor • Capacitor • Low Voltage terminals for evaporator interconnection • Large capacity suction accumulators • Factory installed solid core filter drier • Heat pump circuits equipped with thermostatically controlled crankcase heater • Common suction pressure access point • Hard Start Assist sYstEM oPtIons • Sea Coast Style Coated Coils / Copper-Copper coils • Wind Baffles - Louvers Web: Enviromaster International LLC s2H dIMEnsIons and sPECIFICatIons s2H dIMEnsIons and sPECIFICatIons notE: All EMI products are subject to ongoing development programs so design and specifications may change without notice. 1/2” Diameter Lag Holes 4.63” 4.63”28.74” 12.44” 3.00” 44” 38” 15” Electrical connections Front of unit Easy access interconnects on back of unit s2H ELECtrICaL sPECIFICatIons ModEL (1) VoLts/HZ/PHasE Fan CoMPrEssor 1 CoMPrEssor 2 totaL aMPs MIn. CIr. aMPs (2) HaCr BrKr rLa HP rLa Lra rLa Lra 9900 208-230/60/1 1.8 0.33 3.4 23 3.4 23 8.6 9.5 15 2200 208-230/60/1 1.8 0.33 4.3 27 4.3 27 10.4 11.5 15 9200 208-230/60/1 1.8 0.33 3.4 23 4.3 27 9.5 10.6 15 (1) Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor) (2) Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units. s2H PIPInG sPECIFICatIons sound data sHIPPInG WEIGHt Model# Line sizes Liquid suction dBa Lbs. 9900 1/4” 1/2” 64 159 2200 1/4” 1/2” 65 197 9200 1/4” 1/2” 65 187 Made in rome, new York, usa s2Ha High Capacity Condensing unit S2H s2H sYstEM PErForManCE WLH CAH s2H / WLH sYstEM PErForManCE ModEL CooLInG HEatInG s2H (Outdoor) Indoor units Btuh sEEr sHr EEr Btuh HsPF C.o.P. 9900 WLH09 + WLH09 18,600 13.0 .80 12.2 16,000 7.7 3.3 2200 WLH12 + WLH12 22,600 13.0 .72 11.9 20,000 7.7 3.3 9200 WLH09 + WLH12 20,600 13.0 .76 12.0 18,000 7.7 3.3 s2H / CaH sYstEM PErForManCE ModEL CooLInG HEatInG s2H (Outdoor) Indoor units Btuh sEEr sHr EEr Btuh HsPF C.o.P. 9900 CAH12 + CAH12 18,600 13.0 79 11.7 15,700 7.7 3.1 2200 CAH12 + CAH12 22,600 13.0 .75 11.6 20,000 7.7 3.2 9200 CAH12 + CAH12 20,600 13.0 .77 11.6 18,000 7.7 3.1 S2H WLH CAH S2H s2H sYstEM PErForManCE WLH CAH s2H / WLH sYstEM PErForManCE ModEL CooLInG HEatInG s2H (Outdoor) Indoor units Btuh sEEr sHr EEr Btuh HsPF C.o.P. 9900 WLH09 + WLH09 18,600 13.0 .80 12.2 16,000 7.7 3.3 2200 WLH12 + WLH12 22,600 13.0 .72 11.9 20,000 7.7 3.3 9200 WLH09 + WLH12 20,600 13.0 .76 12.0 18,000 7.7 3.3 s2H / CaH sYstEM PErForManCE ModEL CooLInG HEatInG s2H (Outdoor) ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories