Log:
Évaluations - 5, GPA: 4 ( )

Instructions Invacare, Modèle IRC 1705

Fabricant : Invacare
Taille : 320.07 kb
Nom Fichier : 1148073.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


DO NOT use while bathing. DO NOT place or store product where it can fall or be pulled into a tub or sink. DO NOT place in or drop into water or other liquid. DO NOT reach for a product that has fallen into water. Unplug IMMEDIATELY. Part No 1148073 7 Invacare® Select IMPORTANT SAFEGUARDS WARNING To Reduce the Risk of Burns, Electrocution, Fire and Injury to Persons: This product should NEVER be left unattended when plugged in. Close supervision is necessary when this product is used by, on, or near children and physically challenged individuals. Use this product only for its intended use as described in this manual and only with the prescribed medication. Use this product only under physician’s direction. NEVER operate this product with a damaged cord or plug, if it is not working properly, if it was dropped or damaged, or if it was dropped into water. Call qualified service personnel for examination and repair. Invacare® Select 8 Part No 1148073 IMPORTANT SAFEGUARDS WARNING Keep the nebulizer tubing, cord, and unit away from heated or hot surfaces, including space heaters, electric blankets, stoves and similar electrical appliances. NEVER drop or insert objects into any opening or hose. NEVER use while sleeping or drowsy. NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air openings may be blocked. Keep the air openings free from lint, hair and the like. Blocked openings may cause the unit to shut down. Contact dealer immediately. The compressor nebulizer system uses the surrounding air to effectively administer the prescribed medication through the nebulizer. The user and administrator should be aware of surroundings so as not to have contaminated air filtered through the compressor nebulizer system. (Examples can be air contaminated with paint or cleaning fumes, weed killer, car exhaust, etc.) DO NOT use the compressor nebulizer system in these environments. Otherwise, serious bodily injury may occur. This unit is oil.less. DO NOT lubricate. Part No 1148073 9 Invacare® Select IMPORTANT SAFEGUARDS WARNING This equipment is not suitable for use in the presence of a flammable anesthetic mixture with air or with nitrous oxide. When not administering treatment, keep out of the reach of small children. Some of the parts of the nebulizer are small enough for children to swallow. The tubing may present a strangulation hazard NEVER touch the unit with wet hands. DO NOT pull on the power cord to unplug the unit from an electrical outlet. DO NOT overload wall outlets. Maintenance MUST be performed by a qualified service technician. SAVE THESE INSTRUCTIONS Invacare® Select 10 Part No 1148073 INTRODUCTION INTRODUCTION The Invacare Select Compressor Nebulizer System is a portable medical device designed to efficiently deliver physician.prescribed medication to the bronchial lung passages. The nebulizer system consists of the following components: • Compressor • Nebulizer •Air tubing •Mouthpiece Part No 1148073 11 Invacare® Select TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS Electrical Requirements: 115 VAC, 60Hz, Single Phase Running Current: 1.1 A @ 14 psig @ 115 volts (approx.) Sound Level: 58 to 63 dBA Power Wattage: 65 watts @ 14 psig Electric Motor: Class B in compliance with UL2111. Foam Intake Filter: Rayon Fiber Filter Safety Systems: High temperature compressor shutdown. Width: 6.4 inches Height: 5.5 inches Depth: 3.3 inches Weight: 3.2 Ibs Shipping Weight: 3.8 lbs Regulatory Listing: In compliance with UL 1431 Personal Hygiene and Healthcare Appliances and CSA 22.2 Electromedical Equipment. Maximum Pressure: 36 psi Maximum Flow Rate: 8 to 11 L/min. Operating Flow Rate: 4.0 L/min. @ 16 psi operating pressure Invacare® Select 12 Part No 1148073 TYPICAL PRODUCT PARAMETERS Storage Conditions: -13°F to 158°F (-25° to 70°C); 10 to 95% RH Operating Conditions: 50°F to 104°F (10°C to 40°C); 10 to 95% RH Altitude: 0 to 6000 ft (1825 m) above sea level Mode of Operation: Intermittent Use (30 min. ON / 30 min. OFF) NOTE: Product parameters and appearance are subject to change without notice for purposes of improvement. NOTE: Nebulization rate and particle size are dependent on the characteristics of the nebulizer chosen. Part No 1148073 13 Invacare® Select SUPPLEMENTAL INFORMATION SUPPLEMENTAL INFORMATION Compressor If the unit shuts downfrequently, you may have a low voltage situation. Low voltage can also be suspected when: •The motor does not get up to full power or speed. •Home fuses or circuit breakers activate when starting compressor. •Lights dim or remain dim when compressor is started. •Other motor operated appliances fail to operate properly or too many motor operated appliances are on same circuit. Extension Cords If you must use an extension cord, use only a cord having the same or higher electrical rating as the device being connected. Make certain the extension cord is in good condition without any exposed wires or hazardous contacts...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories