Log:
Évaluations - 4, GPA: 3.3 ( )

Instructions Giant, Modèle BPHV

Fabricant : Giant
Taille : 1.89 mb
Nom Fichier : 1709e0e0-345a-484e-8ae3-37e1930f4352.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


MAIN COMPONENTS of PHV Series constant pressure variable speed system • One multistage vertical pump, Goulds Pumps SSV series. • Hydrovar® pump mounted variable speed drive • Pressure transducer for constant pressure control, connected to the Hydrovar drive. • NEMA 4X fused disconnect panel with corrosion resistant durable plastic; external on/off switch with lockout/tagout. Panel is bracket mounted directly to pump. • Electrical panel for control and protection, with casing made of plastic material, NEMA 4X, equipped with: – fast acting fuses. The panel is mounted on the electric pump using a bracket. The pump package comes pre-assembled and tested, complete with operating instructions and panel wiring diagram. 1) Vertical multi-stage stainless pump 2) TEFC standard NEMA 2-pole motor 3) NEMA 4X fused disconnect panel 4) ITT Hydrovar® variable speed controller 5) cUL flexible liquid tight conduit/wiring 6) Pressure transducer (sensor) with cable 7) Outdoor use CUSUL® Listed “QCZJ7 Packaged Pumping System” PART NUMBERING / IDENTIFICATION CODES — PHV SERIES PACKAGED HYDROVAR VARIABLE SPEED SSV PRODUCT LINE NUMBERING SYSTEM The various versions of the PHV line are identified by a product code number on the pump label. The number is also the catalog number for the package. The meaning of each digit in the product code is shown below. PHV 02 M 2 1 B E 0 P Option List in order shown: P = Premium Efficiency F = Harmonic Filter T = 500 PSI Transducer Reduced Stages (33-46SV Only) (can be 0, 1 or 2)*: 0 = 0 reduced 1 = 1 reduced 2 = 2 reduced Number of Stages: A = 1 E = 5 J = 9 N = 13 S = 17 Z = 24 B = 2 F = 6 K = 10 P = 14 T = 18 C = 3 G = 7 L = 11 Q = 15 V = 20 D = 4 H = 8 M = 12 R = 16 X = 22 Flange Type: A = NPT Oval B = ANSI D = 316SS ANSI Pump Model: 1 = 1SV 2 = 2SV 3 = 3SV 4 = 4SV 5 = 33SV 6 = 46SV 7 = 66SV 8 = 92SV Voltage: 2 = 230V 4 = 460V Hydrovar Type: M = Master Controller HP Rating: 02 = 2 HP 03 = 3 HP 05 = 5 HP 07 = 7. HP 10 = 10 HP 15 = 15 HP PHV - Series (SSV & Hydrovar Package) * Notes: Indicates number of reduced diameter impellers in the total staging. (2 would indicate 2 reduced diameter impellers.) CAUTION: 500 PSI transducer measures accurately to 400 PSI. Pump, flanges and other piping system components must also be rated for the maximum system pressure. See SSV technical manual and other appropriate technical manuals to verify all equipment is rated to maximum system pressure. Notes: 1. Not all combinations are available. 4. Fuse box contains class J or equal fast acting fuses. 2. Standard motor is Baldor TEFC, 3 Phase, TC frame. 5. Tank, piping and valves sold separately. 3. Standard Hydrovar VSD is master - capable of multi-control. 6. Includes 300 PSI transducer. HYDROVAR VARIABLE SPEED CONTROLLERS Hydrovar variable speed drives are identified by the following code. The meaning of each digit in the product code is shown below. HV M 3 4 10 Filter (optional): Standard = Blank Residential = B HP Rating: 02 = 2 HP 03 = 3 HP 05 = 5 HP 07 = 7 HP 10 = 10 HP 15 = 15 HP Voltage: 2 = 230V 4 = 460V Phase: 1 = Single Phase 3 = Three Phase Type: M = Master S = Single B = Basic HV - Series Notes: 1. Not all combinations are available. 2. Includes drive, mounting hardware, 300 PSI transducer and conduit gland and plugs. MARKETS AND APPLICATIONS Booster MARKETS SERVED Sets MUNICIPAL, COMMERCIAL, INDUSTRIAL APPLICATIONS • Water network supply in condominiums, offices, hotels, shopping centers, factories, water treatment, process control. • Water supply to agricultural water networks (e.g. irrigation). • Variable flow / demand applications requiring constant pressure control. PHV Series SPECIFICATIONS • Flow rate up to 320 GPM. • Head up to 692’ TDH. • Supply voltage: 1O, 230V ± 10% up to 3 HP. 3O, 400V ± 10% for 3 HP – 15 HP. • Input Frequency: 50 or 60 Hz. • External control voltage: 0-5 VDC; 0-10 VDC; 0-20 mA. • Protection class - panel: NEMA 4X. - drive: NEMA 4 up to 15 HP. - outdoor use. • Maximum HP: 15 HP. • Soft motor start. • Vertical design pump: - SV..T series (motor insulation class, F, TEFC enclosure). • Maximum operating pressure: 360 PSI for sets with SV..T electric pumps. • Maximum temperature of pumped liquid: 180° F. MARKETS AND APPLICATIONS (continued) WATER SUPPLY AND PRESSURE BOOSTING • Pressure boosting in buildings, hotels, residential complexes • Pressure booster stations, supply of water networks • Booster packages WATER TREATMENT • Ultrafiltration systems • Reverse osmosis systems • Water softeners and de-mineralization • Distillation systems • Filtration LIGHT INDUSTRY • Washing and cleaning plants (washing and degreasing of mechanical parts, car and truck wash tunnels, washing of electronic industry circuits) • Commercial washers • Firefighting system pumps IRRIGATION AND AGRICULTURE • Greenhouses • Humidifiers • Sprinkler irrigation HEATING, VENTILATION AND AIR CONDITIONING (HVAC) • Cooling towers and systems • Temperature control systems • Refrigerators • Induction heating • H...

Ce manuel est également adapté pour les modèles :
matériel de pompage - BPHV (1.89 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories