Facilité d'utilisation
This mark can be used to check the charge status of the battery. 2 1 Plenty of charge left 1 2 2 2 1 Plenty of charge left 1 2 2 1.4 Attaching and charging the battery [Removing the battery] Turn the lock lever anticlockwise and remove the battery. Lift up the battery pack and remove it from the instrument. 2 1 • Be absolutely sure to turn the power off when removing the battery as removing the battery while the power is still on may result in damage to the instrument. 1 3 Get the spare battery ready Replace with the spare battery Low battery: Please change. Replace with the spare battery or charge. [Charging the battery] • The battery BP02 is not charged at our factory shipment so charge it. • For BP02 charge, use the special BC03 charger. [Installation of battery] 4 3 2 1 Draw the battery to the lock lever side and put it on the battery pocket. The battery is firmly installed on the battery pocket. Press down the battery and then slide it to the opposite direction of the lock lever. The lock lever goes up, and the battery is fixed. Under such a condition, if “Connection of the code” is done, the charge with the battery is begun. Power supply cord AC adaptor Charger [Connection of code] Insert the output plug of the power supply code in Jack of the AC adaptor. Insert the output plug of the AC adaptor in Jack of the charger. Insert the power supply plug of the power supply code in the outlet of AC power supply. 3 2 1 Lock lever Battery Battery pocket Charger [Detaching the battery] Press the lock lever and slide the battery to the lock lever direction. Detach the battery packing from the battery pocket. 2 1 [Display panel] Installation lamp Charge lamp Power lamp Discharge lamp Discharg button 4 2 1 5 3 5 4 3 2 1 5 4 3 2 1 Power supply lamp (red) : Turns on when the power supply is turned on. Charge lamp (green): Turns on while charging and turns off when the charge is completed. Discharge lamp (yellow): Turns on when you push the discharge button. Turns off when the discharge is completed. Installation lamp (red): Blinks or turns on when the battery packing is attached normally. Blinks when charge or discharge and turns on when charge is completed. (The charge lamp in the lower does not blink and does not turns on) Discharge button: Discharge lamp lights when you push this button, and the discharge of battery begins. [How to charge] 4 3 2 1 It begins charging automatically when you set the battery packing in the charger which beams the power supply lamp. Leave just as it is until the charge is completed. When the charge is completed, the charge lamp is turned off. Detach the battery packing from the charger when the charge is completed. [Refreshing the battery] The use time shortens gradually by the phenomenon of “Effect of the memory” when the NiMH battery leaves capacity and repeats the charge. The voltage recovers after refreshing and the use time returns normally in such a battery. Please refresh one degree every five times of the charge. [Refreshing] Set the battery in the charger as well as the case of the charge. Push the electrical discharge button. The electrical discharge lamp lights and the electrical discharge begins. The electrical discharge lamp is turned off when the electrical discharge ends, the charge lamp lights, and the charge starts automatically. Leave just as it is until the charge is completed. When the charge is completed, the charge lamp is turned off. Detach the battery from the charger. [Time of refreshing and charge] Battery BP02 is discharged from the state of a full charge at about 960 minutes and the charge is completed from the electrical discharge at about 130 minutes. However, the electrical discharge time is proportional to the remainder capacity of the battery. Moreover, the time required for refreshing might be different from the above-mentioned time according to a surrounding temperature and the state of the battery. 2. DISPLAY AND KEYBOARD 2.1 Display and keyboard Alphanumeric and +/- key Enter key Power supply key Function key Illumination key ESC key Laser plummet and Electronic vial key 2.2 Operation key Key Description [POWER] ON/OFF of power supply [ESC] Returns to previous screen or cancels an operation. [ILLU] Turns the illumination of the LCD display and telescope reticle on and off. [ENT] Accepts the selected (highlighted) choice or the displayed screen value. [LASER] Displays the laser plummet *1, electronic vial function, and the LD point screen when you push the laser plummet/electronic vial key. (Refer to “2-5 Laser Pointer”, “3-2 Laser plummet”, and “3-5 Leveling with Electronic vial”). *1: Only the product with the laser plummet function [Alphanumeric] At the numerical value screen, the numerical value and the sign “.” displayed are input. The English characters printed right under numeric of each key are input. [HELP] Pressing [lLLU]+[ESC] key causes a help menu to appear in A MODE or B MODE or causes a help message to appear. 2.3 Function Key Display...
Ce manuel est également adapté pour les modèles :Instruments d'optique - R-315EX(NX) (1.2 mb)
Instruments d'optique - R-315EX(NX) (1.2 mb)
Instruments d'optique - R-323EX(NX) (1.2 mb)
Instruments d'optique - R-325EX(NX) (1.2 mb)