Log:
Évaluations - , GPA: ( )

Instructions Starmax Resource, Modèle STARMAX 9824

Fabricant : Starmax Resource
Taille : 25.28 kb
Nom Fichier :

Langue d'enseignement: en

Le document est chargé, s'il vous plaît patienter
Le document est chargé, s'il vous plaît patienter

Facilité d'utilisation


(Note, actual selected than 1/4 turn. alignment screw will vary.) If the alignment screw is a large screw First, using the 3mm Allen wrench, turn the large screw clockwise a small amount, no more than a 1/4 turn. (Figure 4a) Now, with the 2mm Allen wrench turn the two adjacent small screws (Figure 4b) counterclockwise no more than 1/4 turn. Locate the small screw that is 180° opposite the first screw (Figure 4c) and turn it clockwise no more than 1/4 turn. Figure 4c: Turn the small Figure 4d: Turn the two screw that is 180° opposite large screws adjacent to the the first screw clockwise no small screw counterclockwise more than 1/4 turn. no more than 1/4 turn. Turn the two large screws adjacent to the small screw (Figure 4d) counterclockwise no more than 1/4 turn. Repeat the above steps until the front opening is centered in the direction you wanted it to go.You may need to repeat this (or the small screw adjustment process) with other screws in order to align it in other directions. Figure 5a Figure 5cFigure 5b Figure 5d Figure 5a: Using the 2mm Figure 5b: Now, with the Allen wrench, turn the large 3mm Allen wrench turn the screw counterclockwise a small two adjacent large screws amount, no more than 1/4 of a clockwise no more than turn. (Note: Actual selected 1/4 turn. alignment screw will vary.) If the alignment screw is a small screw First, using the 2mm Allen wrench, turn the small screw counterclockwise a small amount, no more than a 1/4 turn. (Figure 5a) Now, with the 3mm Allen wrench, turn the two adjacent large screws (Figure 5b) clockwise no more than 1/4 turn. Locate the large screw that is 180° opposite the first screw (Figure 5c) and turn it counterclockwise no more than 1/4 turn. Finishing Collimation Once you have finished adjusting your telescope, you will need to perform another star test (described earlier) to check the collimation. If your telescope appears collimated after star testing, it should not need adjustment again unless it is roughly handled. Figure 5c: Turn the Figure 5d: Turn the two large screw that is 180° large screws adjacent to the opposite the first screw small screw clockwise no counterclockwise no more more than 1/4 turn. than 1/4 turn. Turn the two small screws adjacent to the large screw (Figure 5d) clockwise no more than 1/4 turn. Repeat the above steps until the front opening is centered in the direction you wanted it to go.You may need to repeat this (or the large screw adjustment process) with other screws in order to align it in other directions. Repeat these two procedures as needed until the view through the scope resembles Figure 2b. If you have gone through this process and your telescope is still out of collimation, please contact Orion customer sup- port.You may need to return the telescope for repair (covered on warranty for 1 year after purchase). ...

Ce manuel est également adapté pour les modèles :
Instruments d'optique - STARMAX 127 (25.28 kb)
Instruments d'optique - STARMAX 90 (25.28 kb)
Instruments d'optique - STARMAX 9820 (25.28 kb)
Instruments d'optique - STARMAX 9823 (25.28 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories