Log:
Évaluations - 3, GPA: 4 ( )

Instructions Haier, Modèle DE SERIES DE45EK

Fabricant : Haier
Taille : 3.25 mb
Nom Fichier : de65ek_manual.pdf
Langue d'enseignement: enfr
Aller à la télécharger



Facilité d'utilisation


If this situation develops, disconnect the power supply before touching, stepping into, or attempting to clean up the water. Repair and replace immediately all electric service cords that have become frayed or otherwise damaged. DO NOT use a power cord that shows signs of damage anywhere along its length, at the plug, or where it is connected to the appliance. Always unplug dehumidifier before servicing or moving the unit. CAUTION • DO NOT cover the dehumidifier's air vents. • DO NOT allow children to climb on or play with the dehumidifier. • ALWAYS contact a professional for service and repair. WARNING: You can be killed or seriously injured if you do not follow the instructions in this manual. Please keep these instructions for future reference. THANK YOU... ... for purchasing this Haier appliance. This easy-to-use manual will help you get the best use out of your dehumidifier. Please record the model number, serial Staple your receipt to this manual, number, and store information here. The You will need it to obtain warranty service, model and serial numbers can be located inside the unit after removing the bucket. Model Number Serial Number Date of Purchase Store Name Store Address Store Phone 3 ENGLISH BEFORE USING YOUR DEHUMIDIFIER Please read this manual carefully. It contains Instructions to help you use, maintain, and get the most use out of your dehumidifier. Electrical Safety_ Grounding This dehumidifier must be grounded to reduce the risk of electric shock by providing an escape wire for the electric current. This dehumidifier has a power cord with a grounding wire and a grounded 3-prong plug. ONLY PLUG INTO AN OUTLET THAT IS PROPERLY INSTALLED AND GROUNDED. DO NOT, under any circumstances, cut or remove the third (ground) prong from the power cord. WARNING J k Improper use of the grounding plug can result in the risk of an electric shock, injury, fire, or death. Call a qualified electrician if you do not understand the grounding instructions, or if you are not sure if the dehumidifier is properly grounded. If the wall outlet is not grounded, please contact a professional electrician to have it replaced with a properly grounded outlet. Power Supply Cord Wiring Requirements 115 Volt (103.5 min. - 126.5 max) 15 amp time-delay fuse or circuit breaker Adapter plug is not recommended... however... Since most 2-prong outlets are not grounded, we strongly advise against using an adapter plug. HOWEVER, a temporary connection may be made where local codes permit if the 2-prong wall outlet is properly grounded. FOR SAFETY REASONS, make sure the larger prong of the adapter goes into the large slot. Extension Cord If an extension cord is required to reach the nearest wall receptacle, use only a UL-listed, 3-wire, grounding type, 16 AWG, 15A, 125V appliance extension cord. NO OTHER EXTENSION CORD IS PERMITTED. FOR PROPER GROUNDING Ground the adapter to the outlet by using the outlet cover screw to secure the ground terminal to the outlet box. Be absolutely certain that the outlet is grounded through the house wiring. DO NOT USE the dehumidifier until a proper ground has been made. 4 FAMILIARIZE YOURSELF WITH THE CONTROLS ON YOUR DEHUMIDIFIER. — SMART DRY HIGH BUCKET FULL NAL LOW SPEED ON OFF F/C Hr CURRENT I HUMIDITY SET TIIVER HUMIDITY/Til/IE (7) (6)© (4) Control Panel CHECK FILTER FILTER REÎ ET POWER © © Features: © Power Press POWER once to turn the dehumidifier ON and press POWER again to turn the dehumidifier OFF. NOTE:After the unit is plugged in, but before the unit is turned on, press and hold the POWER button for 5 seconds to switch the temperature display between Fahrenheit (F) and Celsius(C) degrees. Auto Restart Once the power is restored, after 3 minutes, the unit begins to operate at its previous operation setting depending on the humidity conditions. NOTE: Auto-Defrost Sensor (built in) When the temperature is 60°F or lower, ice may form on the evaporator coils preventing the removal of moisture. When this occurs, the controller stops the compressor, but allows the fan to continue running. When the ice is no longer present, the compressor will restart. 2 ) Check Filter Indicator The "check filter" indicator will flash when the filter needs to be cleaned. Remove the filter, wash it, and put it back in. Press "Filter Reset." The "check filter" indicator will turn off. Note: Make sure the filter is dry before replacing. © © Humidistat This allows you to adjust the humidity in the air. You can set the humidity to your desired level by pressing □ and □ keys. ©Timer Your dehumidifier can be set to turn on and off at pre-determined times. Pre-setting can be programmed up to 24 hours in advance. © Two Fan Speeds This key controls the fan speed. There are two speed levels, LOW and HIGH. ©Smart Dry This setting compares the set humidity level with the actual humidity level and adjusts the fan speed automatically. © Sig...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories