Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Cleveland Range, Modèle Floor Type Gas Convection Steamer 24CGA10.2

Fabricant : Cleveland Range
Taille : 3.99 mb
Nom Fichier : 63fe025c-e02b-4317-ba5b-61080112927d.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions. The information in this document may be subject to technical and technological changes, revisions, or updates. Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates. Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out / tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas, electric, and steam powered equipment and / or appliances All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of operation according to OSHA approved practices during any servicing of Cleveland Range equipment Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date knowledge, skills, materials and equipment. CLEVELAND RANGE GEMINI 24CGA 6.2 AND 24CGA10.2 SEQUENCE OF OPERATIONS Mechanical Timer Starting with the timed manual switch in the timed position, and no time on the timer. To turn the unit on, turn the ON/OFF lever clockwise to the ON position This mechanically closes the drain. The red “Power On” indicator is energized. 115 VAC is sent through the timer to the three-second timer, which activates the buzzer for three seconds. 115 VAC is sent through the normally closed R1 contacts to the fan motor, turning it ON 115 VAC is sent to H and N of the water level board With the water level board energized and no water in the generator 115 VAC is sent from the FILL terminal to the fill solenoid. The fill solenoid opens and the generator fills. The water fills to the low probe shorting it to ground 115 VAC is sent from the HEAT terminal to the timed manual switch. 115 VAC is sent through the high limit to the primary of the 24VAC transformer. The water continues to fill until the water level reaches the high probe then 115 VAC is removed from the FILL terminal and the fill solenoid is turned off 24VAC is sent to the ignition module. Spark is sent to the igniter. 24VAC is sent to the pilot coil of the gas valve and the coil of the R1 relay. The normally closed R1 contacts open, turning off the fan The pilot lights, which acts as a standby heater. When the pilot is ignited and the module detects 1.0 micro amps DC, the MV terminal on the module is energized it remains in this standby heat mode until a cooking compartment is turned “ON” (see step 5). When the timed/manual switch is in the timed position and time is on the timer or the timed manual switch is set to the manual position: 115 VAC is sent to the clean light timer. When the clean light timer times down 115 VAC is sent to the clean light switch. When the clean light switch is depressed the timer is reset. 115 VAC is sent from the compartment timer through the door switch to the normally closed contacts of the compartment thermostat and R2 relay coil. The “Sure Cook” light is energized. 115 VAC is also sent from the door switch through the now closed contacts of the R1 relay to the fan motor. The fan motor turns ON, and comes up to speed. The fan prover switch makes allowing 24 VAC to the normally open R2 contacts. The normally open R2 contacts close and 24 VAC is sent to the main coil of the gas valve. The main burner is ignited and the water heated to steam. Steam enters the cabinet and the compartment thermostat closes at 193 degrees. The “Sure Cook” light is de-energized. If in the timed mode, 115 VAC is sent to the timer motor and the timer begins counting down. The condensate solenoid is energized sending cold water down condensate spray nozzle pulling the steam around the product and down the drain. When the timer times out or the unit is switched to the timed mode (with no time on the timer) from the manual mode, 115 VAC is sent to the 3 second timer and then to the buzzer for 3 seconds. Whenever the water level drops below the high probe for 5 seconds 115 VAC is sent to the FILL terminal again. When the on/off lever is turned off : The drain is mechanically opened, and the generator begins to drain. The red “Power On” indicator light is de-energized. 115 VAC is sent to the 3-minute timer and the fill solenoid is energized for 3 minutes flushing the drain. ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories