Log:
Évaluations - 4, GPA: 4 ( )

Instructions Blodgett, Modèle SN-5E

Fabricant : Blodgett
Taille : 483.97 kb
Nom Fichier : SN-E-man.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. Intended for commercial use only. Not for household use. This manual should be retained for future reference. TABLE OF CONTENTS DESCRIPTION PAGE Important Notes For Installation and Operation ................................................................. 2 Service Connection ............................................................................................................ 4 1.0 Installation Instructions .............................................................................................. 5 2.0 Testing Procedures ................................................................................................... 9 3.0 Operation ................................................................................................................ 10 4.0 Cleaning .................................................................................................................. 13 5.0 Maintenance ........................................................................................................... 14 6.0 Adjustment for High Altitude ..................................................................................... 15 7.0 Troubleshooting ...................................................................................................... 16 SERVICE CONNECTION CELECTRICAL CONNECTION: O1 1/8" hole for electrical connection. Rating to be as specified on data plate. DRAIN: 1"IPS to open floor drain. No solid connection. Use copper only, 24" length before open air gap opening (No bends or elbows). GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa) CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa) WATER QUALITY STATEMENTWATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF WATERQUALITY, CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANALYZED. YOUR WATER SUPPLY MUST BETOTAL DISSOLVED SOLIDSTOTAL ALKALINITYSILICACHLORINEpH FACTORWATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER. FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY. LESS THAN 60 PPMLESS THAN 20 PPMLESS THAN 13 PPMLESS THAN 1.5 PPM7.0-8.5WITHIN THESE GENERAL GUIDELINES: ELECTRICAL CHARACTERISTICS17 [432]27.5 [698] 15[ 381] 24[ 610] 1.75 [45] 1.75[ 45] 3[76] 1.13 [29] SN-3ESN-5E1.5[38] 12.5[ 318] 19[ 483] 20 [508] OPTIONAL LEGS15.12[ 384] 4 [102] 21.62[549] SN-5ESN-3E1[ 25] 23.5 [597]2 [51] 1/2-NPT DELIME INLETDIMENSIONS ARE IN INCHES [MM] 1.0 INSTALLATION INSTRUCTIONS GENERAL The SN-3E and SN-5E steamers are single compartment electric pressureless steam cookers with an internal electric steam generator that maintains water temperature at approximately 205.F. SN-3E is rated 7.5 kW as standard; 10 kW is optional. SN-5E is rated 12 kW as standard; 15 kW is optional. At high altitude locations a lower temperature is required to achieve atmospheric steaming. Contact your authorized service office to have the thermostat adjusted if the steamer will be operated at high altitudes. INSTALLATION UNPACKING Immediately after unpacking the steamer, check for possible shipping damage. If the steamer is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery. Prior to installation, verify that the electrical service agrees with the specifications on the machine data plate which is located on the left side panel. LOCATION Allow space for plumbing and electrical connections. Allow adequate access for operating and servicing the steamer (36" at the front of the steamer and 15" above the steamer). LEGS (OPTIONAL) If the optional 4" adjustable legs are used, remove the four levelling feet on the bottom of the steamer. LEVELING Using a spirit level or pan of water in bottom of steamer chamber, adjust feet to level steamer front to back and side to side. After drain is connected, check for level by pouring water onto the floor of the compartment. All water should drain through opening in rear. ANCHORING STEAMER 1. Place steamer in desired location with level counter top and mark four corners. Remove steamer and drill ." holes as indicated in Figure 1. 2. Apply a bead of RTV or other equivalent sealant around bottom perimeter edge of steamer. Failure to comply with this requirement will void the NSF label. 3. Set steamer on counter and bolt down securely with 3/8 - 16 bolts. FIGURE 1 DRAIN CONNECTIONS The drain connection must be 1" IPS vertically down, preferably with one elbow only, and maximum length of 6 feet, piped to an open air gap...

Ce manuel est également adapté pour les modèles :
Paquebots - SN-3E (483.97 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories