Log:
Évaluations - 3, GPA: 3.7 ( )

Instructions Yamaha, Modèle YPDR601

Fabricant : Yamaha
Taille : 2.78 mb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


STOP and PAUSE work in the same way as they do for a tape recorder. PLAY starts disc playback, and REC and PLAY together start the recording of audio data. However, for data to be recorded (either audio or TOC), the STDB Y key must first be pressed in order to position the laser. The top row of transport keys provide additional functions. The REC MUTE mutes the input signal to the recorder. The AUTO PAUSE key is used in the TOC PRE mode to complete recording of the pre-defined track (this key has no function in the TOC AFTER mode). The TOC key is used with the RECORD key to record TOC information in either the TOC PRE or TOC AFTER modes, and the Tr INC and I xINC are used to write track and index information respectively, in real time. In TOC PRE mode, the Tr I NC key has no function, as track information is pre-written. (0) TRACK keys These keys are used when the disc is stopped or playing, and allow setting of a track, to play the disc from the selected track. (Q) SEARCH These keys may be used when the disc is paused or playing. They allow searching for a particular point on the disc within a track by ear, rather than by index position (similar to CUE and REVIEW on a tape recorder). (g) REHEARSAL The rehearsal mode tests the cue point of the source machine. Press this key (which will light) to go into and out of rehearsal mode. When in rehearsal mode, pressing PLAY and REC simultaneously will start the YPDR in rehearsal mode, which will stop automatically after 10 seconds. The appropriate "PLAY" and "STOP" commands are transmitted from the REMOTE connector (16) and Parallel I/O connector (18) to the source machine, allowing monitoring of the record start point. YPDR Remote controller (RC601) - 14 4 • Remote controller (RC601) - Rear panel 4.2 Rear panel (T) PHONES connector A stereo 1/4" connector for headphone monitoring of the signal selected using the INPUT/REPRO key on the front panel. (2) PHONES LEVEL A level control for the headphones connected to the PHONES connector (1). This control has no effect on the output level from the main unit. ©DRIVE SELECT When used with a single-recorder configuration, this rotary switch should be set to "0". When used in a multi-recorder setup, this switch should be set to the number of recording units being used, minus 1 (eg if three units are being used, this should be set to "2"). (4) DIP switch bank The four switches in this bank have the following functions: EMPHASIS When this is set ON (up), and an analog source is being used, emphasis will be added to the signal recorded on the disc. When a digital source is used, this switch has no effect (emphasis will be recorded depending on the presence or absence of emphasis in the digital source). PEAK HOLD When set to ON, the meters on the front panel will act as peak hold meters (the highest level will be displayed for a short time before "falling back"") When OFF, the meters will act as momentary peak meters. COPY GUARD This switch enables or disables the writing of the copy-protection flag. EXT W. SYNC When using an analog source or an SDIF-II digital source, this selects either external word clock synchronization (ON) or internal word clock synchronization (OFF). When using a AES/EBU digital source, this switch has no effect, and the YPDR will synchonize to the source. YPDR Remote controller (RC601) - 15 4 • Remote controller (RC601) - Rear panel (5) INPUT SELECT switches These determine the type of source. The first switch allows selects either analog or digital input, and the second selects the type of digital source: either AES/EBU or SDIF-II (D.IN). If the first switch is set to ANALOG, the position of the second switch has no effect. (D TOC switches These determine the recording mode, as explained in the first section of this manual ("TOC PRE" on page 3 and "TOC AFTER" on page 3). The first switch allows the choice of TOC PRE (99 fixed-length tracks) or TOC AFTER (a variable number of variable-length tracks), and the second switch allows the selection of either 10 or 30 seconds as the fixed track length when in TOC PRE mode. When the first switch is set to AFTER, the position of the second switch has no effect. ©POWER switch This rocker switch controls the power to the controller (independent of the main unit). (8) CONTROL connector Use the supplied 50-conductor cable to connect the controller to the main unit's I/O IN (15). (9) AC IN This is the connector for the AC power cord (supplied) YPDR Remote controller (RC601) - 16 5 • Connection - Audio connections 5 • Connection NOTE: Make all control and audio connections before connecting power to either the main unit or the controller. If power connections have already been made, and the system is being re-configured, make sure all components on the system are turned OFF before proceeding. 5.1 Audio connections The YPDR may be connected to any monitoring system using the -2dB ANALOG OUT (4) connectors. Headphone mon...

Ce manuel est également adapté pour les modèles :
Lecteurs - RC601 (2.78 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories