Log:
Évaluations - 3, GPA: 4 ( )

Instructions Desa, Modèle S26NTA

Fabricant : Desa
Taille : 1.47 mb
Nom Fichier : 33ad78e1-c60a-acf4-fd28-0566a86961a9.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


This will only last a few hours. 1. STOP! Read the safety information, above. 2. Make sure equipment shutoff valve is fully open. 3. Turn control knob clockwise to the OFF position. 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 19). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 6. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 15. 7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again. 8. Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO. CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. Ignitor Button Control Knob Figure 19 - Control Knob and Ignitor Button Location TO TURN OFF GAS TO APPLIANCE Shutting Off Heater Turn control knob clockwise to the OFF position. Shutting Off Burners Only (pilot stays lit) Turn control knob clockwise to the PILOT position. THERMOSTAT CONTROL OPERATION The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases. MANUAL LIGHTING PROCEDURE 1. Follow steps 1 through 5 under Lighting Instructions, page 14. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 Lighting Instructions, page 14 OPERATING HEATER Continued Ignitor Electrode Thermocouple Pilot Burner Thermocouple Pilot Burner Figure 20 - Pilot Figure 21 - Correct Pilot Flame Pattern (Natural Gas Shown) Thermocouple Pilot Burner Figure 22 - Incorrect Pilot Flame Pattern (Natural Gas Shown) Approx. 3-6" Above Top of Logs Figure 23 - Correct Flame Pattern with Control Knob Set to High Flame More Than 8" Above Top of Logs Inspecting Burners Check pilot flame pattern and burner flame patterns often. PILOT FLAME PATTERN Figure 21 shows a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 22 • turn heater off (see To Turn Off Gas to Appliance) • see Troubleshooting, page 18 Note: The correct pilot flame on natural gas units will have a slight curve, but flame should be blue an have no yellow or orange color. Burner FLAME PATTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If burner flame pattern is incorrect, • turn heater off (see To Turn Off Gas to Appliance) • see Troubleshooting, page 18 Figure 24 - Incorrect Flame Pattern with Control Knob Set to High Flame Cleaning and Maintenance WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc. WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage. Burner Injector Holder and Pilot Air Inlet Hole The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season...

Ce manuel est également adapté pour les modèles :
Plate - S26PTA (1.47 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories