Log:
Évaluations - 2, GPA: 5 ( )

Instructions Harman Company, Modèle HARMAN P68

Fabricant : Harman Company
Taille : 2.12 mb
Nom Fichier : P68.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


4 2"(51mm) 36"(914mm) 14" (355mm) with side shields 20" (508mm) without side shields 14" (355mm) 20" (508mm) MinimumSizefloorprotection(USA)is33"DeepBy25" Wide. * Floor protection dimensions for the front and sides are measured from the appliance door opening in The United States. In Canada, the side dimension is measured from the widest part of the appliance. jj K l uSa canada note: Measurement "L" is measured from the pedestal base in the US ONLY note: Measurement "K" is measured from the glass in the US ONLY Floor protector Fig. 3 the Structural integrity oF the ManuFactured hoMe Floor, Wall, and ceiling/rooF MuSt be Maintained. Warning do not inStall in SleePing rooM. venting requirements for terminating the venting Warning: Venting terminals must not be recessed into a wall or siding. note: Only PL vent pipe wall pass-throughs and fire stops should be used when venting through combustible materials. note: Always take into consideration the effects of the prevailing wind direction or other wind currents that may cause flyash and/or smoke when placing the termination vent. in addition, the following must be observed: A. The clearance above grade must be a minimum of 18".1 B. The clearance to a window or door that may be opened must be a minimum of 48" to the side, 48" below the window/door, and 12" above the window/ door.1 ( with outside air installed, 18” ) C. A 12" clearance to a permanently closed window is recommended to prevent condensation on the window. D. The vertical clearance to a ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the center-line of the terminal must be a minimum of 18". E. The clearance to an unventilated soffit must be a minimum of 12". F. The clearance to an outside corner is 11" from center of pipe. G. The clearance to an inside corner is 12". H. A vent must not be installed within 3 feet (90 cm) above a gas meter/regulator assembly when measured from the horizontal center-line of the regulator.1 I. The clearance to service regulator vent outlet must be a minimum of 6 feet.1 J. The clearance to a non-mechanical air supply inlet to the building or the combustion air inlet to any other appliance must be a minimum of 48”.1 K. The clearance to a mechanical air supply inlet must be a minimum of 10 feet.1 (with outside air installed, 6 feet ) L. The clearance above a paved sidewalk or a paved driveway located on public property must be a minimum of 7 feet.1,2 M. The clearance under a veranda, porch, deck or balcony must be a minimum of 12 inches.1,3(See b.) note: The clearance to vegetation and other exterior combustibles such as mulch is 36” as measured from the center of the outlet or cap. This 36” radius continues to grade or a minimum of 7 feet below the outlet. 1Certain Canadian and or Local codes or regulations may require different clearances. 2A vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings. 3Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor. note: Where passage through a wall, or partition of combustible construction is desired, the installation shall conform to can/cSa-b365. (if in canada) = Vent terminal v 8 P68 Pellet Stove3-90-00688R20_10/12venting A combustion blower is used to extract the combustion gasesfromthefirebox.Thiscausesanegativepressureinthefireboxandapositivepressureintheventingsystem as shown in Fig. 7. The longer the vent pipe and moreelbowsusedinthesystem,thegreatertheflowresistance. Because of these facts we recommend using as few elbows as possible and 15 feet or less of vent pipe. The maximum horizontal run should not exceed 48". If more than 15 feet of pipe is needed, the interior diameter should be increased from 3" to 4" because alargerpipecauseslessflowresistance.be sure to use approved pellet vent pipe wall and ceiling pass- through fittings to go through combustible walls and ceilings. all joints for connector pipe must be fastened with a minimum of three screws. Follow pellet vent manufacturer instructions for properly securing each pellet vent joint. the pellet starting collar must be secured to the unit's flue collar. venting iMPortant notice Approved 3" or 4" Pellet Vent Pipe Such As, Type "PL", Must Be Used. + + - Fig. 7 vent Pipe Pellet venting pipe (known as PL vent) is constructed of two layers with air space between the layers. This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of 1 to 3 inches. The sections of pipe lock together to form an air tight seal in most cases. However, in some cases a perfect seal is not achieved. For this reason and the fact that the P68 operates with a positive vent pressure we specify that the joints also be sealed with high temp (rtv) silicone. Aluminum tape can also be used for any joint that is 1ft. or more from the outlet of the stov...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories