Log:
Évaluations - 1, GPA: 5 ( )

Instructions Carrier, Modèle COMFORT 48EZ-A

Fabricant : Carrier
Taille : 2.23 mb
Nom Fichier : om48ez-vt-04.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit. 2 UNIT INTRODUCTION ! WARNING FIRE AND EXPLOSION HAZARD Failure to follow this hazard warning could result in personal injury, death and/or property damage. What to do if you smell gas: 1. Do not try to light any appliance. 2. Do not touch any electrical switch; do not use any phone in your building. 3. Leave the building immediately. 4. Immediately call your gas supplier from a nearby phone. Follow the gas supplier’s instructions. 5. If you cannot reach your gas supplier, call the fire department. ! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury and/or death. Before performing recommended maintenance, be sure the main power switch to unit is turned off and lock- -- out tag is installed. The 48EZ- --A and 48VT- --A units are small packaged gas heat/electric heat pump systems that can utilize both the efficiency of heat pump heating and the comfort of gas heating. The system will optimize for ideal heating, depending on several factors. This unit uses Puron®, the ozone friendly refrigerant, for cooling and heat pump heating. Starting or Shutting Off Unit NOTE: Your combination heating/cooling unit is equipped with an automatic direct spark ignition and power combustion blower. To start unit gas heat: Refer to Fig. 3 for location of unit front access panel. Refer to Fig. 4 for location of gas valve. Refer to Fig. 5 while proceeding with the following steps. 1. Set the temperature selector on room thermostat to the lowest temperature setting and set system switch to Emergency Heat. 2. Close the external manual gas shutoff valve. 3. Turn off the electrical supply to the unit. 4. Remove the control access panel with a 5/16- --in. nut driver. (See Fig. 3.) ! WARNING FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Failure to follow this hazard warning could result in personal injury, death and/or property damage. 1. Do not turn off the electrical power to unit without first turning off the gas supply. 2. Before attempting to start the gas heating section, familiarize yourself with all the procedures that must be followed. ! WARNING FIRE, EXPLOSION HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. Do not attempt to light by hand. ! CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. When removing access panels or performing maintenance functions inside your unit, be aware of sharp sheet metal parts and screws. Although special care is taken to reduce sharp edges to a minimum, be extremely careful when handling parts or reaching into the unit. Filter Access Panel Blower Access Panel Control Access Panel Compressor Access Panel For Accessory Filter Rack A09213 Fig. 3 - --Unit Access Panels 5. Move the selector switch on the internal gas valve to the OFF position and wait 5 minutes. 6. Move the selector switch on the internal gas valve to the ON position. 7. Replace the control access panel. 8. Turn on the electrical supply to unit. 9. Open the external manual gas shutoff valve. 10. Set the temperature selector on room thermostat slightly above room temperature to start unit. The induced- --draft combustion air fan will start. Main gas valve will open and main burners should ignite within 5 seconds. If the burner does not light within 5 seconds, the ignition module will go into a Retry Mode after a period of approximately 22 seconds (following the 5- --second ignition period). If the burners do not light within 15 minutes of the initial call for heat, there is a lockout. 3 4 11. Set the temperature selector on room thermostat to desired setting. FIRE AND EXPLOSION HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. 1. If the main burners fail to light, or the blower fails to start, shut down gas heating section and call your dealer for service. 2. Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the following shutdown procedures, then call your dealer as soon as possible. ! WARNING Burners Gas Valve Flue Hood A09043 Fig. 4 -- Gas Heating/Electric Cooling Unit with Access Panel Removed To shut off unit gas heat: FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. Do not turn off the electrical power to unit without first turning off the gas supply. ! WARNING NOTE: If the unit is being shut down because of a malfunction, call your dealer as soon as possible. Should overheating occur or the gas supply fail to shut off, shut off the external manual gas valve to the unit before shutting off the electrical supply. Do not use this unit if any part has been under water. Immediately call a qualified service technician to...

Ce manuel est également adapté pour les modèles :
Plate - COMFORT 48VT-A (2.23 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories