Log:
Évaluations - 1, GPA: 4 ( )

Instructions Zanussi, Modèle ZGG 646 ITN

Fabricant : Zanussi
Taille : 1.3 mb
Nom Fichier :
Langue d'enseignement: ruentr
Photos et spécifications   Zanussi  ZGG 646 ITN
Aller à la télécharger



Facilité d'utilisation


.. Check the mains fuse has not blown. .. Check the burner cap and crown have been replaced correctly, e.g. after cleaning. .. Check the main jet is not blocked and the burner crown is clear of food particles. .. Check the burner cap and crown have been replaced correctly, e.g. after cleaning. 12 OVERALL DIMENSIONS Width: 580 mm Depth: 510 mm CUT OUT DIMENSIONS Width: 550 mm Depth: 470 mm APPLIANCE CLASS 3 SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230 V ~ 50 Hz supply, 3 core flexible cable HEAT INPUT Rear Left Burner 1.9 kW (semi rapid) Front Left Burner 2.9 kW Natural gas (rapid) 2.7 kW Liquid gas Rear Right Burner 1.9 kW (semi rapid) Front Right Burner 1.0 kW (auxiliary) APPLIANCE CATEGORY II2H3B/P GAS SUPPLY Natural gas G20 20 mbar Instructions for the Installer Engineer technical data 13 TYPE BURNER INJECTORS NORMAL REDUCED NORMAL FEEDING OF GAS POWER POWER POWER PRESSURE 1/100 mm kW kW m3/h g/h mbar Rapid 119 2,9 0,75 0,276 - Semi-rapid 96 1,9 0,45 0,181 - 20 Auxiliary 70 1,0 0,33 0,095 - Rapid 86 2,7 0,75 - 196 Semi-rapid 71 1,9 0,45 - 138 30 Auxiliary 50 1,0 0,33 - 73 Rapid 120 1,8 0,75 0,191 - Semi-rapid 105 1,4 0,45 0,148 - 13 Auxiliary 80 0,9 0,33 0,095 - * Injectors for natural gas G20 13 mbar are for Russia only NATURAL GAS LIQUID GAS NATURAL GAS * Burner O By-pass in 1/100 of mm Auxiliary 28 Semi-rapid 32 Rapid 42 Table 2 : Injectors Table 1 : By-pass diameters 14 .. The following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force. .. The appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensure all the necessary precautions are followed. .. The side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top. .. Avoid installing the appliance in the proximity of inflammable materials (e.g. curtains, tea towels etc.). THE MANUFACTURER WILL NOT ACCEPT LIABILITY, SHOULD ANY OF THE OTHER SAFETY INSTRUCTIONS INCORPORATED IN THIS BOOKLET OR THE REGULATION IN FORCE BE IGNORED. Instruction for the Installer Gas Connection Choose fixed connections or use a flexible pipe instainless steel in compliance with the regulation in force. If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not squeezed. Use the same attention when the hob is combinated with an oven. IMPORTANT - To ensure a correct operation, a savingof energy and the long life of the appliance, the voltage pressure of the appliance must correspond to the recommended values. The adjustable connection is fixed to the comprehensive ramp by means of a threaded nut G 1/2". Interpose the sealing between the components as shown in Fig. 3. Screw the parts without forcing, adjust the connection in the required direction and tighten everything. 15 Connection using flexible non metal pipes When the connection can be easily inspected in its full extent, there is the chance to use a flexible pipe according to the rules in force. The flexible pipe must be tightly fixed using clamps according to the rules in force. Always insert the gasket «B». Then proceed with the gas connection. The flexible pipe should be made ready for use in such a way that: - nowhere it can reach overtemperature, other than room temperature, higher than 30°C; if the flexible pipe, to reach the cock, must run behind the range, it must be installed as shown in Fig. 3; - it is no longer than 1500 mm; - it shows no throttles; - it is not subject to traction or torsion; - it doesn't get in touch with cutting edges or corners; -it can be easily inspected in order to check its condition. The control of preservation of the flexible pipe consistsin checking that: - it doesn't show cracks, cuts, marks of burnings bothon the end parts and on its full extent; - the material is not hardened, but shows its normal elasticity; - the fastening clamps are not rusted; - expiry term is not due. If one or more abnormalities are seen, do not repair the pipe, but replace it. It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. Failure to ensure the correct assembly will cause leakage of gas. IMPORTANT Once installation is complete, check the perfectseal of every pipe fitting, using a soapy solution, never a flame. Natural gas A) Ramp with ending nut Fig. 3 B) Seal C) Adjustable connection 16 The appliance is designed to be connected to 230 V monophase electricity supply. The connection must be carried out in compliance with the laws and regulations in force. Before the appliance is connected: 1) check that the main fuse and the domestic installation can support the load (see the rating label); 2) check that the power supply is properly earthed in compliance with the current rules; 3) check the socket or the double pole sw...

Ce manuel est également adapté pour les modèles :
Plate - ZGG 643 ITN (1.3 mb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories