Log:
Évaluations - 4, GPA: 4.5 ( )

Instructions Drolet, Modèle ECO-65

Fabricant : Drolet
Taille : 1.97 mb
Nom Fichier : 45433A_25_10_2010.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If problem persists, contact your dealer. FUSE Branchement electrique_Page_2 5. ELECTRICAL DIAGRAM FIGURE 24 COMPOSANTES-AN.jpg pc board C:\Documents and Settings\ngagnon\Bureau\carte.bmp FIGURE 25 FIGURE 26 5.1. FUSE ACCESS All fuses are located inside the pc board box, you must remove the pc board cover to access the fuse. To do so, simply remove the 5 screws securing it in place. Make sure you put the pc board box back in place before you restart the unit. FIGURE 27 6. REPLACEMENT PARTS Contact an Authorized DROLET Dealer to obtain any of these parts. Never use substitute materials. Use of non- approved parts can result in poor performance and safety hazards. ITEM PART # COIL HANDLE AC07867 SCREW PLATE GASKET 21193 EXHAUST BLOWER GASKET 21194 HOPPER SCREW PLATE GASKET 21195 EXHAUST BLOWER CLEANOUT TRAP GASKET 21344 REAR LHSCLEANING GASKET 21352 FRONT LEFT CLEANING 21348 RIGHT CLEANING GASKET 21349 CONVECTION BLOWER WOOL 21350 SCREW ASSY 24030 NUT 1/8" PIPE 30164 RING 17/64" TYPE "AA" 30205 WING NUT 1/4-20 30416 HOPPER LID PLASTIC HANDLE 30527 BRASS BUSHING FOR PELLET STOVE AUGER 30528 BEARING 30545 FIRE POT LATCH 30686 1/2" ROPE FIBERGLASS GASKET OA11395 PRESSURE SWITCH GRANULE 44029 THERMODISC 36T12 F160 44058 THERMODISC 36T11 L250 AUTOMATIC 44059 THERMISTOR 44095 PELLET STOVE SECURITY SWITCH 44098 COMBUSTION BLOWER 44104 EXHAUST FAN ASSEMBLY SE62293 GEAR MOTOR FOR PELLET STOVE 1.7 44106 BURN POT GEAR MOTOR 44109 CONVECTION BLOWER 44108 I/O CONTROL PC BOARD 44138 IGNITER 44133 MEMBRANE SWITCH 44139 PIPE CLAMP 49400 AIR PUMP 60047 ELBOW BRASS 90 60101 AIR INTAKE DUCT COMPRESSIBLE 21077 FIBERGLASS 5/16" GASKET AC06300 REMPLACEMENT HANDLE KIT AC09155 DOOR LATCH T KIT AC09185 BURN POT SE62254 ASH DRAWER SE62290 GLASS SE62400 MEMBRANE SWITCH ALPHANUMERIC MODULE 44140 APPENDIX A HORIZONTAL AND VERTICAL VENT CHART Possible Vertical vent length (feet) Possible Horizontal vent length (feet) For example, let.s imagine an installation consisting of a horizontal vent coming out at the back of the stove on a total distance of 8 feet. This horizontal run is followed by a Tee and a 6-foot vertical rise. This type of installation is not acceptable. As you can see, the vent termination is clearly outside the allowed configuration zone on the chart because the venting system proposed does not have at least one foot of vertical rise for each foot of horizontal run. Instead, if the installation consisted of a horizontal vent coming out at the back of the stove on a total distance of 4 feet, followed by a Tee and a 6-foot vertical rise, it would be acceptable. The installation end should be within the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot of horizontal run. Furthermore, the total vertical rise would be at least 3-foot high. WARNING: TO REDUCE THE RISK OF SMOKE SPILLAGE, NEVER TERMINATE WITH A HORIZONTAL RUN. IF YOUR SYSTEM TERMINATES WITH A HORIZONTAL RUN, ADD AT LEAST 3 FEET OF VERTICAL RISE. Rapport d'inspection ECo-65.jpg APPENDIX B DROLET LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your DROLET dealer. This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of maintenance, over firing, negligence, accident during transportation, power failures, downdrafts, or venting problems are not covered by this warranty. This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or chemical cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty. An authorized qualified technician must perform the installation in accordance with the instructions supplied with this product and all local and national building codes. Any service call related to an improper installation is not covered by this warranty. The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will repair or replace such defect. Transportation fees to ship the product back to the purchaser will be paid by the manufacturer. Repair work covered by the warranty, executed at the purchaser.s domicile by an authorized qualified technician requires the prior approval of the manufacturer. Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part. All parts and labour costs covered by this warranty ...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories