Log:
Évaluations - 2, GPA: 4.5 ( )

Instructions Drolet, Modèle DH04200

Fabricant : Drolet
Taille : 449.98 kb
Nom Fichier : d0b9a34f-610c-78a4-d1b9-b1b38ee40b06.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


OWNER`S MANUAL OIL BURNING STOVE EVEREST Verified and tested following CAN/CSA B140.3 et UL 896 standards by: Intertek Testing Services Manufactured by: 1700 Leon-Harmel Quebec, (Quebec) G1N 4R9 tel : (418 ) 527-3060 Fax : (418 ) 527-4311 READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE TABLE OF CONTENT TECHNICAL DATA.........................................................................................................................................1 INSTALLATION INSTRUCTIONS..................................................................................................................2 LOCATING THE STOVE.........................................................................................................................2 CHIMNEY INFORMATIONS....................................................................................................................3 CONNECTING THE STOVE TO THE CHIMNEY...................................................................................4 LEVELING THE UNIT..............................................................................................................................5 FIXATION OF STOVE TO FLOOR..........................................................................................................6 CONNECTING STOVE TO OIL TANK....................................................................................................6 AJUSTEMENT THE DRAUGHT..............................................................................................................7 OPERATION INSTRUCTIONS.......................................................................................................................8 COMBUSTIBLE.......................................................................................................................................8 LIGHTING PROCEDURES.....................................................................................................................8 CHANGING INTENSITY..........................................................................................................................9 TURNING THE STOVE OFF...................................................................................................................9 CLEANING PROCEDURES....................................................................................................................9 TROUBLESHOOTING GUIDE..............................................................................................................10 TECHNICAL DATA EVEREST OIL BURNING STOVE COMBUSTIBLE : OIL NO 1 OIL NO 2 HEAT INPUT : Kw BTU/h Kw BTU/h Minimum: 5,9 20 450 4,8 16 600 Maximum: 10,9 37 250 9,6 33 150 FLOWRATE : cc/min litres/h cc/min litres/h Minimum: 9,9 0,60 7,5 0,45 maximun: 17,3 1,04 16,1 0,97 MINIMUM DRAUGHT REQUIRED : 0,06 INWC 0,06 INWC EFFICIENCY : % % with fan : 78,5 79 without fan : 77 77 CLEARANCES TO COMBUSTIBLES Mm in Back 255 10 Side 255 10 Corner 255 10 Top 915 36 A MINIMUM CLEARANCE OF 9’’ (230 mm) FROM SINGLE WALL FLUE PIPE TO COMBUSTIBLES MUST BE ALLOW...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories