Log:
Évaluations - 4, GPA: 3.5 ( )

Instructions Hearth and Home Technologies, Modèle CB1200-B

Fabricant : Hearth and Home Technologies
Taille : 1.23 mb
Nom Fichier : 08dfe1db-0e5d-4c4b-a281-6747b0ecd756.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


• Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. Installations with: 3 to 3 inch Top Vent Adapter and 3 to 6 inch Offset Adapter Kit Vertical Installation Inches Millimeters D Back Wall to Flue Pipe 3 76 E Side Wall to Top 6 152 F Back Wall to Appliance 7.5 191 D E F G G Corner Installation Inches Millimeters G Walls to Appliance 2 51 Page 8 7014-082D September 1, 2008 R R CB 1200 Pellet Stove C. Hearth Pad Requirements (UL and ULC) Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door. L* KK M Figure 9.1 Hearth Pad Requirements Inches Millimeters K Sides 2 51 L* Back 2 51 M Front 6 152 *L Exception for Horizontal Installations: USA INSTALLATIONS: A non-combustible floor protection is recommended extending beneath the flue pipe when installed with horizontal venting or under the top vent adapter with vertical installation. CANADA INSTALLATIONS: A non-combustible floor protection extending beneath the flue pipe is required with horizontal venting or under the top vent adapter with vertical installation. Must extend 2 inches (51mm) beyond each side of pipe (shaded area) Figure 9.2 September 1, 2008 7014-082D Page 9 CB 1200 Pellet Stove 4Vent Information R A. Chimney and Exhaust Connection 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be vented vertically or horizontally. 2. Mobile Home: Approved for all Listed pellet vent. If using the 3 inch (76mm) vertical top vent adapter Kit or the 3 to 6 inch (76-152mm) top vent offset adapter, use Listed double wall flue connector. A Quadra-Fire outside air kit must be used with manufactured home installations. 3. Residential: The 3 inch (76mm) vertical top vent adapter kit and the 3 to 6 inch (76-152mm) top vent offset adapter are tested to use 24 gauge single wall flue connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting national and/or local codes for solid fuel appliances. 4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. 5. Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint. NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only). NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instructions from the venting manufacturer. WARNING Fire Hazard. • Only LISTED venting components may be used. • NO OTHER vent components may be used. Substitute or damaged vent components may impair safe operation. WARNING Vent surfaces get HOT, can cause burns if touched. Noncombustible shielding or guards may be required. B. Venting Termination Requirements CAUTION Do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc. 1. Termination must exhaust above air inlet elevation. It is recommended that at least 60 inches (1524mm) of vertical pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically through the roof. 2. Distance from doors and opening windows, or gravity or ventilation air inlets into building: a. Not less than 48 inches (1219mm) below; b. Not less than 48 inches (1219mm) horizontally from; c. Not less than 12 inches (305mm) above. 3. Distance from permanently closed windows: a. Not less than 12 inches (305mm) below, horizontally from or above. 4. Distance between bottom of termination and grade should be 12 inches (305mm) minimum. This is conditional upon plants in the area, and nature of grade surface. The grade surface must be a non-combustible material (i.e., rock, dirt). The grade surface must not be lawn. Distance between bottom of termination and public walkway should be 84 inches (2134mm) minimum. 5. Distance to combustible materials must be 24 inches (610mm) minimum. This includes adjacent buildings, fences, protruding parts of the structure, roof overhang, plants and shrubs, etc. 6. Termination Cap Location (Home Electrical Service) • Side-to-side clearance is to be the same as minimum clearance to vinyl inside corners. • Clearance of a termination cap below electrical service shall be the same as minimum clearance to vinyl soffits. • Clearance of a termination cap above elec...


Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories