Log:
Évaluations - 3, GPA: 4 ( )

Instructions Jenn-Air, Modèle Gas Cooktops JGC8536ADB

Fabricant : Jenn-Air
Taille : 11.27 kb
Nom Fichier : 09990985.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


spacing from cooktop edge to nearest vertical combustible wall to the RIGHT: Min. spacing from cooktop edge to nearest vertical combustible wall to the LEFT: Min. spacing from cooktop edge to nearest vertical combustible wall to the REAR: Minimum spacing to front edge of counter: Minimum distance between cooktop and cabinet directly above: Minimum width of cabinet directly above: Maximum depth of cabinets directly above and adjacent: Minimum distance between countertop and adjacent cabinet above: • Additional Information 8" 8" 3/4" 2" 30" min 36" 13" 18" • • Distance from top of counter to bottom of gas stub is 4 9/16". • Distance from top of counter including manifold entrance is 7 1/2. • Electrical requirements : 110/120 volt AC, 60hz. Must be grounded. 15amp circuit required. Locate outlet below the cooktop a minimum of 5" below the countertop if not installing over an under counter oven. Locate outlet below the oven or in an adjacent cabinet when installing over an adjacent under counter oven. • Minimum clearance from top of counter to combustible material below is 4 7/16" • Countertop must be supported within 3" of cutout. • Unit may be installed over a Jenn-Air under counter oven. See page 2 for additional information Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2003. 321 3 13/16" Side View (not to scale) 20 13/16" 34 7/8" 18" 36" 30" min 36" 21 9/16" Overall Dimensions Top View (not to scale) Cut-Out Dimensions Countertop View (not to scale) Cabinet Requirements Wall View (not to scale) Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 8" (see solid areas) Top view of cutout (not to scale) 1 3/4" to centerline of pipe from back edge of cutout Gas inlet location 1 3/4" from left sideof cutout to centerline of pipe. Cooktop supplied with 1/2" NPT female inlet on regulator • NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. BN182.34 • A321B149 • • 031111 • 115727 • 89750 DIMENSION EXPRESS Fax on Demand (775) 833-3600 Additional Information: • Gas requirements : The Appliance pressure regulator supplied with this appliance is pre...

Ce manuel est également adapté pour les modèles :
Plate - Gas Cooktops JGC8536ADQ (11.27 kb)
Plate - Gas Cooktops JGC8536ADS (11.27 kb)
Plate - Gas Cooktops JGC8536ADW (11.27 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories