Log:
Évaluations - 3, GPA: 4 ( )

Instructions LST, Modèle 45681-290

Fabricant : LST
Taille : 92.31 kb
Nom Fichier : 1c9e814b-9991-4524-932e-a6ec5d257989.pdf
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


They can be used in combination with a detector or strobe, or as stand-alone device. For the latter case an optional white or red plastic lid is available. Furthermore, the sounders are equipped with an integrated dual-isolator module. Two different tone types, depending on the sounder model, are available, and they can be selected during parameterisation of the Fire Detection Control Panel Se- ries BC216. If several sounders are actuated in parallel, they are synchronized by Fire Detection Control Panels Series BC216 to generate a uniform warning tone. In case of activation, the sounder is tested acoustically by means of an integrated microphone. The address of the sounder as well as the sound level are selected by means of a DIL switch. The base sounders have been designed for indoor mounting. An optional mounting plate is available for surface mounted cabling. • ADM loop technology with Apollo/Discovery protocol • Integrated detector base with dual-isolator • Warning tone 1kHz • Slow whoop tone – NEN 2575 • Emergency signal tone – DIN 33404 • Sound level selectable in two steps– up to 91dB(A) • Integrated acoustical self test Integrated Base Sounder 45681-277, 45681-290, 45681-300 Specifications Operating voltage 17 – 28VDC Description The Integrated Base Sounders 45681-277, 45681-290 and 45681-300 are fitted into a round, white plastic case with an integrated base for accommodating au- tomatic Fire Detectors or Strobes Series XP95 or Dis- covery. The sounders are powered and actuated as modules via the ADM loop with Apollo/Discovery protocol. They can be used in combination with a detector or strobe, or as stand-alone device. For the latter case an optional white or red plastic lid is available. Furthermore, the sounders are equipped with an integrated dual-isolator module. Two different tone types, depending on the sounder model, are available, and they can be selected during parameterisation of the Fire Detection Control Panel Se- ries BC216. If several sounders are actuated in parallel, they are synchronized by Fire Detection Control Panels Series BC216 to generate a uniform warning tone. In case of activation, the sounder is tested acoustically by means of an integrated microphone. The address of the sounder as well as the sound level are selected by means of a DIL switch. The base sounders have been designed for indoor mounting. An optional mounting plate is available for surface mounted cabling. • ADM loop technology with Apollo/Discovery protocol • Integrated detector base with dual-isolator • Warning tone 1kHz • Slow whoop tone – NEN 2575 • Emergency signal tone – DIN 33404 • Sound level selectable in two steps– up to 91dB(A) • Integrated acoustical self test Integrated Base Sounder 45681-277, 45681-290, 45681-300 Specifications Operating voltage 17 – 28VDC Current consumption max. 200.A (sounder off) max. 5mA (sounder on) Sound level 55 – 75dB(A) or 75 – 91dB(A) Ambient temperature -20°C to +60°C Dimensions o . H 115 . 38 (mm) Colour...

Ce manuel est également adapté pour les modèles :
Alarme incendie - 45681-277 (92.31 kb)
Alarme incendie - 45681-300 (92.31 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories