Instructions Firex, Modèle IAR230C

Fabricant : Firex
Taille : 150.82 kb
Nom Fichier :
Langue d'enseignement: en
Aller à la télécharger



Facilité d'utilisation


If a bedroom area hallway is more than 9 m long, install a smoke alarm at each end. •Install a smoke alarm at the top of a first-to-second floor stairwell. Key • Smoke Alarm . Smoke Alarm with False Alarm Control 2 IMPORTANT SMOKE ALARM PLACEMENT AND EXCEPTION INFORMATION: •Install a smoke alarm as close to the centre of the ceiling as possible. If this is not practical, mount no closer than 10 cm (4 inches) from a wall or corner. Also, if local codes allow, install smoke alarms on walls, between 10 and 30 cm (4 and 12 inches) from ceiling/ wall intersections. •Install a minimum of two smoke alarms in every home, no matter how small the 10cm 10cm MINIMUM 30cm MAXIMUM CEILING SIDE WALL ACCEPTABLE HERE NEVER HERE TOP OF DETECTOR ACCEPTABLE HERE home. Any size home requires fitting a minimum of two smoke alarms. •Install a smoke alarm in each room that is divided by a partial wall (either coming down from the ceiling at least 20 cm (8 inches), or coming up from the floor). •Install smoke alarms on peaked, cathedral, or gabled ceilings 1 m from the highest point (measured horizontally). •Install a smoke alarm in lived-in attics or attics which house electrical equipment like furnaces, air conditioners, or heaters. DO NOT install smoke alarms: 20cm STUB WALL SOFFIT 1M PEAKED CEILING Near appliances or areas where normal combustion regularly occurs (kitchens, near boilers, hot water heaters). Use specialized smoke alarms with unwanted alarm control for these areas. In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 3 metres away from these areas. Near air returns or heating and cooling supply vents. The air could blow smoke away from the detector, interrupting its alarm. In rooms where temperatures may fall below 5°C (41°F) or rise above 45°C (113°F). In extremely dusty, dirty, or insect-infested areas. Loose particles interfere with smoke alarm operation. ! ! ! DANGER: WARNING: WARNING: HOW TO INSTALL THIS SMOKE ALARM ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF position and securing it. Mains operated smoke alarms should be installed by a qualified electrician in accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers (BS). Failure to install this smoke alarm correctly may expose the user to shock or fire hazards. The smoke alarm, its associated supply and interconnect wiring must be installed in accordance with BS 7671 published by the Institution of Electrical Engineers. • Install smoke alarm on a wall, ceiling, standard electrical box, or surface mounting pattress. 1. Align mounting plate with mounting holes of standard electrical box or surface mounting pattress. For siting on wall or ceiling, use mounting plate as template to mark holes. Drill holes (for wall or ceiling only) and insert supplied screw plugs into holes until flush with wall or ceiling. 2. Secure mounting plate to electrical box, pattress, wall, or ceiling. (Diagram illustrates fixing mounting plate to electrical box.) 3. Connect blue wire from connector plug of smoke alarm to neutral (black or blue) mains power wire. 4. Connect brown wire from connector plug of smoke alarm to live (red or brown) mains power wire . 5. If interconnection is desired, connect orange wire from connector to interconnect wire between smoke alarms. See section, “Interconnecting Smoke Alarms.” 3 NOTE: If this will be a sing...

Ce manuel est également adapté pour les modèles :
Alarme incendie - GC240 (150.82 kb)
Alarme incendie - I240C (150.82 kb)
Alarme incendie - PAD240 (150.82 kb)
Alarme incendie - PADC240 (150.82 kb)

Écrivez votre propre critique du dispositif



Texte du message
Votre nom :
Entrez les deux chiffres :
capcha





catégories