On the lookout for leaks.On the lookout for leaks. In the field, the Gas In the field, the GasIn the field, the Gas Hunter HunterHunterdoes the job of seven individual does the job of seven individualdoes the job of seven individual instruments to optimize technician efficiency in leak survey operations instruments to optimize technician efficiency in leak survey operationsinstruments to optimize technician efficiency in leak survey operations and customer service calls. It is able to sniff out combustible gases and customer service calls. It is able to sniff out combustible gasesand customer service calls. It is able to sniff out combustible gases from part per million levels to 100% volume through auto-ranging. from part per million levels to 100% volume through auto-ranging.from part per million levels to 100% volume through auto-ranging. Sensitive and compact, it requires minimal operator training. Sensitive and compact, it requires minimal operator training.Sensitive and compact, it requires minimal operator training. The First Responders Best Friend In The Field • Multiple functions: seven instruments in one small package • Simple operation • Auto-zero at start up • Auto-ranging in combustible gas mode • 3 ranges of sensitivity – PPM, LEL and % gas by volume • State-of-the-art patented sensor technology: one combustible sensor for PPM thru 100% gas by volume • Confined space protection for 3 gases • Audible and visual alarms • Pressure and draft measurements • Ambient and air-free carbon monoxide capability • Superior on-board diagnostics • Intrinsically safe • Compatible with Bacharach’s docking station • Low cost of ownership • Manufacturer of instruments for the natural gas industry for over 50 years • Made in the U.S.A. • Backed by Bacharach’s commitment to quality, service and reliability Bacharach – Leading manufacturer of high-quality instruments for the natural gas industry for over 50 years Seven Instruments in One Small, Rugged Package Leak Search The PPM range of the Gas Sampling mode offers visual, segmented bar-graph, and audible detection of natural gas leaks from 50 ppm to 2,500 ppm. The Hunter serves as an excellent tool for tracking down small leaks; replacing messy soap bubble solutions and broadband MOS type instruments. Leak Survey Higher concentrations of natural gas are easily measured from 0.2 to 100% volume gas with no operator intervention. Auto-ranging makes leak investigations and bar-holing operations simple through Bacharach’s patented sensing technology. This minimizes operator training and eliminates confusing range settings, over-range messages and damage to catalytic sensors as a result of high gas concentration exposure. Carbon Monoxide Calls The 0-1000 ppm carbon monoxide function eliminates yet another instrument that the First Responder must carry on the job. Residential CO surveys are reliably and easily performed with the Gas Hunter. In addition, oxygen and combustible gas levels are monitored simultaneously, but displayed through individual readings. Air-Free Carbon Monoxide In some situations, ambient measurement of carbon monoxide alone may not be adequate. ANSI Z21.1 standard requires an Air-Free calculation for appliance emissions in furnace flues, oven vents and space heaters. Both ambient and air-free carbon monoxide measurement are readily available in the Gas Hunter. Confined Space Entry In the safety mode, audible and visual alarms are activated at OSHA preset levels for combustibles (in the lower Explosive Level), carbon monoxide and oxygen (in enriched and deficient atmospheres). The Gas Hunter serves as a trusty watchdog for technicians working in vaults, trenches or other confined areas. Pressure Monitor Who is to say that a combustible gas detector must be limited to just detecting gas? The addition of low range (0.0 to 27.7" wc) pressure function further separates the Gas Hunter from the competition. Aside from one less tool to carry to the worksite, this function eliminates the use of messy liquid monometers and erratic spring gauges. It gives the service tech the convenience of quick, accurate gas pressure checks on regulators and appliance manifolds. Draft Gauge In the flue mode, the Hunter offers yet another tool alternative in the 0.00 to negative 28" of water column draft function. This enables the service technician to utilize a more accurate and sophisticated method to check draft in hot water tanks and furnace flues. Bar-holing application Leak search application 55-8001 Gas Hunter Kit includes: 4’ polyurethane coiled hose with 10” aluminum probe assembly. 3 AA alkaline batteries, laminated methane/pressure reference card and 2 inlet filters. 55-3001 30” plastic bar hole probe 3474-1210 30” aluminum bar hole probe 55-0063 Water trap/filter assembly for barholing applications 55-8005 Flue probe assembly with sample and draft lines, a water trap/filter assembly and quick connect fittings 24-1107 Water trap/filter assembly for flue probe 55-...