Fabricant : Hoshizaki
Taille : 1.63 mb
Nom Fichier : DCM-300BAH(-OS)_inst.pdf
|
Par ce dispositif a également d'autres instructions :
Facilité d'utilisation
9 B. How to Remove Panels ............................................................................................... 10 C. Location .......................................................................................................................11 D. Setup............................................................................................................................11 E. Electrical Connection .................................................................................................. 12 F. Water Supply and Drain Connections .......................................................................... 13 G. Final Checklist ............................................................................................................ 15 H. Startup ........................................................................................................................ 16 I. Dispense Mode Switch................................................................................................. 17 III. Cleaning and Maintenance ............................................................................................. 18 A. Cleaning and Sanitizing Instructions........................................................................... 19 1. Water System ......................................................................................................... 19 2. Dispensing Components ....................................................................................... 21 B. Maintenance................................................................................................................ 23 C. Preparing the Icemaker for Long Storage ................................................................... 24 3 Important Safety Information Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. WARNING Indicates a hazardous situation which could result in death or serious injury. CAUTION Indicates a situation which could result in damage to the unit. IMPORTANT Indicates important information about the use and care of the unit. WARNING This icemaker should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and therefore dangerous. The manufacturer cannot be held responsible for injury or damage resulting from improper, incorrect, and unreasonable use. To reduce the risk of death, electric shock, serious injury, or fire, follow basic precautions including the following: • Only qualified service technicians should install, service, and maintain the icemaker. • Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment. • This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuse, or damage to existing wiring. This could lead to heat generation or fire. • THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could result in death or serious injury. • Move the control switch and the power switch to the "OFF" position and turn off the power supply before servicing. Lockout/Tagout to prevent the power supply from being turned back on inadvertently. • Do not make any alterations to the unit. Alterations could result in electric shock, injury, fire, or damage to the unit. 4 I. Specifications A. Electrical Data 1. DCM-300BAH (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-300BAH SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1COMPRESSOR 120V 7.9RLA 39.0RLA GEAR MOTOR 120V 1.45FLA 80W FAN MOTOR 115V 0.8FLA 16W AGITATING MOTOR 120V 0.9FLA 55W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.2A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT AMPACITY 20 AMPS DESIGN PRESSURE HI-460PSI LO-290PSI REFRIGERANT 404A 15.9 OZ. MOTOR-COMPRESSOR THERMALLY PROTECTED NOT INTENDED FOR OUTDOOR USE! Hoshizaki America, Inc. Peachtree City, GA For certification marks, see the nameplate on the rear panel. The rating label and nameplate provide electrical and refrigerant data. The rating label can be seen by removing the front panel. The nameplate is located on the rear panel. We reserve the right to make changes in specifications and design without prior notice. 5 2. DCM-300BAH-OS (air-cooled) HOSHIZAKI ICE MAKER MODEL NUMBER DCM-300BAH-OS SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1COMPRESSOR 120V 7.9RLA 39.0LRA GEAR MOTOR 120V 1.45FLA 80W FAN MOTOR 115V 0.8FLA 16W AGITATING MOTOR 120V 0.9FLA 55W DISPENSING MOTOR 120V 0.9FLA 55W OTHER 120V 0.2A MAXIMUM FUSE SIZE 20 AMPS MAX. HACR BREAKER (USA ONLY) 20 AMPS MAX. CIRC. BREAKER (CANADA ONLY) 20 AMPS MINIMUM CIRCUIT A...