Do not lift the griddle top too high as the thermostat and griddle terminals may be damaged. 3. Remove the fastener near the bottom of the terminal box and slide the enclosure up to expose knockouts. 4. Connect griddle's line leads to the supply wires, as shown in the applicable wiring diagram. Do not disturb the griddle's wiring. 5. Slide enclosure down and secure it with fastener. 6. Lower the griddle top. Make sure that it is securely in place. Since the griddle is not fused, you must connect it to a fused circuit equipped with a suitable disconnecting means as required by local authorities. – 6 – ELECTRICAL DATA — TABLE TWO M O D E L T O T A L K W T E M P. R A N G E (°F) P R E H E A T T I M E (MIN. TO 350°F) W A T T S T O H O L D 400°F PHASE-LOADING AND LINE AMPERES 3-PHASE LOADING NOMINAL AMPERES PER LINE 3-PHASE 1-PHASE KW PER PHASE 208 VOLTS 240 VOLTS 480 VOLTS 208 V. 240 V. 480 V. L1-L2 L2-L3 L1-L3 L1 L2 L3 L1 L2 L3 L1 L2 L3 CG20 8.0 6.0 200450 7 1205 4.0 3.0 0.0 0.0 4.0 3.0 25.0 14.4 14.4 28.9 16.7 16.7 14.4 8.3 8.3 28.8 33.3 16.7 CG41 21.6 200450 7 2100 10.8 5.4 5.4 68.7 68.7 45.2 59.5 59.5 39.0 29.8 29.8 19.5 103.9 90.0 45.0 CG50 CG50 * 16.2 10.8 200400 7 3500 5.4 5.4 5.4 0.0 5.4 5.4 45.0 45.0 45.0 26.0 45.0 26.0 39.0 39.0 39.0 22.5 39.0 22.5 19.5 19.5 19.5 11.3 19.5 11.3 77.9 51.9 67.5 45.0 33.8 22.5 CG55 12.0 200450 7 1808 4.0 4.0 4.0 33.4 33.4 33.4 28.9 28.9 28.9 14.4 14.4 14.4 57.7 50.0 25.0 CG58 16.2 200450 7 2100 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5 33.8 CG59 32.4 ** 200450 7 4200 5.4 5.4 5.4 45.0 45.0 45.0 39.0 39.0 39.0 19.5 19.5 19.5 77.9 67.5 33.8 * Two separate conduit connections must be made; one connection carries 16.2 KW and the other carries 10.8 KW. ** Two separate conduit connections must be made; each connection carries one-half of the rated load. Rated voltages: 208, 240, 480 VAC; 1- or 3-phase, 50/60 Hz. – 7 – FIG. 1 — CG20 FLOOR PLAN FIG. 2 — CG41 FLOOR PLAN – 8 – FIG. 3 — CG50 FLOOR PLAN FIG. 4 — CG55 FLOOR PLAN – 9 – FIG. 5 — CG58 FLOOR PLAN FIG. 6 — CG59 FLOOR PLAN – 10 – FIG. 7 — CG20 WIRING DIAGRAM - 208, 240 & 480 V., 1 & 3 PHASE FIG. 8 — CG41 WIRING DIAGRAM - 208/240 & 480 V., 1 & 3 PHASE – 11 – FOR SUPPLY CONNECTIONS USE COPPER WIRE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND SUITABLE FOR AT LEAST 90°C. (194°F.) LEAD MARKER NUMBERS ARE THE SAME AS LEAD ITEM NUMBERS UNLESS OTHERWISE SPECIFIED. 208/240 V. WIRING TO BE: 480 V. WIRING TO BE: 10 GA., 532515 - LEADS 1-18 10 GA., 532515 - LEAD 11 18 GA., 532518 - LEADS 19-24 12 GA., 532514 - LEADS 8, 10, & 15-18 14 GA., 529358 - LEADS 1-7, 9, & 11-14 18 GA., 532518 - LEADS 19-24 PHASE WIRING JUNCTION BOX RIGHT BODY JUNCTION BOX LEFT BODY SINGLE PHASE: CONNECT WIRES 10 & 12 TO SINGLE PHASE: CONNECT WIRE 18 TO ONE FIELD LINE WIRE AND WIRES 8 & 17 ONE FIELD LINE WIRE AND WIRES 16 & 15 TO THE OTHER FIELD LINE WIRE. TO THE OTHER FIELD LINE WIRE. THREE PHASE: CONNECT WIRES 8 & 10 TO L1 THREE ...
Ce manuel est également adapté pour les modèles :Autres appareils de cuisine - CG50 ML-114582BN41 ML-CG41208S001 (1.12 mb)
Autres appareils de cuisine - CG41 ML-CG41208S001 (1.12 mb)
Autres appareils de cuisine - CG20 ML-43120 (1.12 mb)
Autres appareils de cuisine - CG20 ML-CG20480S001 (1.12 mb)